Thick, salty, alkaline samples. One pressurized electrode.
APERA INSTRUMENTS / LABSEN 851-H · 853-H · 855 / AI3168 / AI3180 / AI3243
LabSen 851-H, 853-H and 855 are non-refillable pre-pressurized pH electrodes for highly viscous samples such as skin care products, coatings, syrups, resin, glue and honey, including samples with high salinity or strong alkalinity. Their HA-type membrane minimizes alkaline error. The 851-H has a BNC connector, the 853-H adds a built-in temperature sensor with an RCA plug, and the 855 is the 8-pin pH/temperature version for PH60 and PH60Z testers fitted with the required 8-pin socket/adapter.
Listed operating envelope: pH 1–14 as a conservative common range; electrode/sample temperature 0–100°C from current US standalone pages, subject to host limits. Choose the version that matches your meter’s connection and temperature requirements from the menu above. Apera warrants LabSen electrodes for six months from delivery.
Only published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.
Start with what makes your sample difficult. Published families link to their product pages. Other models are shown for comparison only; confirm the exact connector and host before choosing.
AI3141 / AI3153
Proteins, dairy, biotech
Protelyte electrolyte and triple ceramic junction.
AI3109 / AI3177 / AI3239
Strong acids, HF
HF-resistant glass; spot measurements below 0.1 mol/L HF.
AI3145 / AI3179 / AI3237
pH 12–14, salinity >0.5%
HA glass minimizes alkaline error; silver ion trap.
AI3110
Skincare, cosmetics, coatings
Conical membrane with Protelyte and triple ceramic junction.
AI3165
Coatings, syrups, resin, glue
Pre-pressurized gel KCl with low-impedance S membrane.
AI3168 / AI3180 / AI3243
Viscous, alkaline or salty
Pre-pressurized gel KCl and HA glass; BNC, BNC/RCA or 8-pin.
AI3167 / AI3176 / AI3241
Hot, caustic, electroplating
PHY glass and PTFE ring junction, rated to 130°C.
AI3147
Organic solvents
PHY glass, double junction with 1M LiCl outer bridge.
BNC versions connect to the pH input of BNC pH meters. They have no temperature sensor: use a separate temperature probe supported by the host meter (Apera’s MP500 only where the meter supports it), or manual temperature entry where available.
BNC/RCA versions carry a built-in 30 kΩ NTC temperature sensor on an RCA plug for automatic temperature compensation on Apera meters with BNC and RCA inputs, such as the PH700, PH850, PH8500, PH820, PH910 and PH9500. Apera notes they may not work with other brands’ meters because the thermistor might not be compatible.
The 8-pin version is a pH/temperature electrode for Apera meters with an 8-pin socket, including the PH60, PH60-Z, PH400, PH400S and the PC400, PC400S, SX736 and SX751. PH60 and PH60Z require the appropriate installed 8-pin socket/adapter; this cabled electrode does not replace the native tester probe directly. Confirm the adapter separately; its inclusion is not implied.
Temperature figures are electrode/sample ratings, not a complete-system rating. Use a meter and temperature-compensation method rated for the actual sample temperature; keep the meter body, cable connection and adapter within their own confirmed limits. Connector fit alone does not establish temperature or ATC compatibility.
Electrolyte flows smoothly outward through the ceramic junction in viscous samples.
Minimizes alkaline error and withstands high temperature.
Stable reference potential and long service life.
Operating envelope: pH 1–14 as a conservative common range; electrode/sample temperature 0–100°C from current US standalone pages, subject to host limits. Common construction: body lead-free glass; glass membrane HA, hemispherical; junction ceramic; reference electrolyte pre-pressurized gel KCl.
The full specification table is in the Product Specifications tab. This listing retains the current US standalone-page temperature limit rather than adopting wider 130°C manual values. It uses a conservative common pH 1–14 range because 853-H regional specifications and 855 kit sources differ at the lower endpoint. The 853-H has BNC/RCA and a 30 kΩ NTC sensor; the 851-H manual is not its instruction manual.
Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring.
Never store a pH electrode in pure, deionized or distilled water.
The 851-H, 853-H and 855 are sealed and need no refilling.
These models are intended for viscous, alkaline or salty sample measurements, not as a blanket recommendation for prolonged immersion or storage in the sample. The 851-H manual both recommends alkaline samples and cautions against strong alkali; confirm suitability with Apera for the actual concentration, temperature and exposure time before demanding caustic use. The exact European 853-H manual cautions against strong acid and dehydrating media such as absolute ethanol or concentrated sulfuric acid. Keep any such exposure brief and clean carefully afterward; store the tip in 3M KCl, not the sample.
Rinse with distilled or deionized water between samples. For stubborn deposits, use Apera electrode cleaning solution, then recondition and recalibrate.
Apera ships this electrode in these kits: PH700-VS (LabSen 853-H), PH60-VS (LabSen 855), PH60Z-VS (LabSen 855).
Calibrate with fresh pH 7.00, pH 4.00 and pH 10.01 buffers, or pH 12.45 for alkaline samples.
LabSen 851-H, 853-H and 855 are non-refillable pre-pressurized pH electrodes for highly viscous samples such as skin care products, coatings, syrups, resin, glue and honey, including samples with high salinity or strong alkalinity.
851-H has BNC for pH only; 853-H adds an RCA-connected 30 kΩ NTC temperature sensor for a compatible Apera meter; 855 uses Apera’s 8-pin connection. PH60/PH60Z need the appropriate installed 8-pin socket/adapter, not a direct native-probe swap. Check host compatibility and adapter supply before ordering.
The pH signal uses BNC, but the built-in 30 kΩ NTC temperature sensor is not universally compatible. Apera lists meters with matching BNC/RCA inputs; verify the meter’s thermistor support and temperature range before relying on ATC.
No; it is sealed and needs no refilling.
Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring. Never use pure, deionized or distilled water.
Apera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.
Do not treat suitability for an alkaline measurement as permission for prolonged immersion or sample storage. The 851-H manual contains conflicting strong-alkali wording; ask Apera to confirm your concentration, temperature and contact time for demanding caustic work. Store all three models in 3M KCl when not measuring.
851-H, 853-H and 855 use HA glass to minimize alkaline error in viscous, alkaline or salty samples. The 853-S uses S-type glass and has different chemical-use restrictions. This H-family listing adopts pH 1–14 and electrode 0–100°C conservatively; it does not upgrade the host meter’s temperature or ATC range.
Check the version, connector and catalog number (AI3168 / AI3180 / AI3243) against your meter and samples, then return to the live price and ordering controls.
APERA INSTRUMENTS, LLC warrants LabSen electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.
This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.
The 851-H manual covers 851-H only. The additional 853-H full manual is Apera Europe’s English edition, accurately scoped to 853-H; confirm regional instructions for the supplied unit. Neither is a standalone 855 manual. Both PDFs list wider temperature limits than this listing’s conservative 0–100°C. The 851-H manual contains conflicting alkaline-use/care wording; do not infer prolonged caustic-immersion suitability.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.