Give us a call at (833)928-4437
A replaceable glass-bulb pH tester for everyday aqueous measurements.
Preparing Quote Cart. Your shopping cart stays unchanged.
APERA INSTRUMENTS / PH60-Z / AI3711
Measure pH and temperature in general aqueous samples without needing a phone. Apera PH60-Z combines button calibration and a clear display with the replaceable PH60-DE glass-bulb probe. Bluetooth supports a separate ZenTest workflow for connected data handling.
Choose AI3711 for liquid immersion, not food penetration or dry surfaces. A replaceable probe separates sensor maintenance from the meter body, not sample-chemistry limits.
Each card opens that kit page, not an upgrade for the current meter. Match the supplied head and supported measurements. Phones and additional probes are not included unless the exact kit contents say so.
AI3711
General aqueous pH
PH60-DE glass-bulb probe; optional ORP60-DA upgrade.
AI3715
Wetted flat surfaces
PH60F-DE flat membrane; defined small-volume method.
AI3713
Moist soft-solid samples
PH60S-DE spear glass; sacrificial sample method.
AI3717
Dedicated ORP
ORP60-DE head; not a pH-convertible body.
AI3718
Conductivity and conversions
EC60-DE head; no pH or supported ORP upgrade.
AI3719
pH plus conductivity
PC60-DE combo head; ORP60-DA sold separately.
AI3803
Combo plus separate ORP head
PC60-Z meter with PC60-DE and separate ORP60-DA.
PH60-DE combines a glass bulb, temperature sensor, double junction and blue inner gel. Wet both the sensing area and reference junction. Keep the glass clear of the vessel bottom.
Automatic recognition supports 1-3 calibration points. Start at neutral, then select standards for your sample range. The default 0.01 pH resolution is a display increment, not guaranteed sample accuracy.
Measure, calibrate and use HOLD without a phone. Correctly assembled, the IP67 enclosure floats. Seat caps and connections securely; protect the glass from impact.
Check general water samples at a bench or sampling point. Use a clean vessel, rinse between locations and compare results at similar temperatures.
Check compatible water-based mixtures during preparation or adjustment. Match calibration standards to the expected pH and verify suitability before testing concentrated reagents, solvents or other aggressive chemistry.
Move between sample locations without a phone. Use stability indication and HOLD consistently; HOLD freezes the display rather than creating stored measurement history.
Prepare fresh portions of calibration buffer. Select the correct USA or NIST family and begin at pH 7.00 or 6.86 respectively. Wait for the stability indicator before confirming, then continue to the next point without powering off. Use at least two points for a more dependable working calibration.
Rinse the probe, immerse it sufficiently to cover the sensing area and reference junction, and stir briefly to release external bubbles. The manual troubleshooting guidance calls for at least one inch of liquid immersion. Hold still until stable, keeping the glass clear of the container wall and bottom.
Allow sample temperature to stabilize. ATC covers 0-50°C and corrects electrode response, not all chemical pH changes with temperature. The -2.00 to 16.00 pH display range is not universal compatibility with strong acids, alkalis, solvents or extreme samples.
Rinse before and after each measurement, including between calibration buffers. Do not rub or wipe the glass bulb. For persistent deposits, follow the probe cleaning instructions with a suitable cleaner, then condition in 3M KCl and recalibrate before returning to samples.
For daily or weekly use, keep the cap wet and tightly closed with its seal in place. For long-term storage, use 3M KCl up to the cap fill line. Do not store the probe immersed in tap, RO, distilled or deionized water; rinsing and storage are different jobs.
Replace damaged or exhausted probes with PH60-DE, AI3711-E. Protect the connector, align without force, tighten the ring, condition and calibrate. Cap solution is not an internal reference refill. Remove a shield only if the fitted probe has a removable one.
Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.
Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.
The tester measures and calibrates without a phone. Connect a compatible smartphone inside ZenTest, rather than treating operating-system PIN pairing as the measurement workflow. Bluetooth, required phone permissions and a nearby powered tester are needed for new connected readings. A smartphone is not included.
ZenTest offers Simple, Dial, Graph and Table views, with manual and timed recording, measurement/calibration records, and tools for notes, photos and location tagging. Available parameters still depend on the exact body and fitted head. Display choices cannot add pH or conductivity to an unsupported model.
Account and cloud functions depend on the compatible app, service and internet connection. Reviewing already saved records while disconnected is not continuous measurement acquisition outside Bluetooth range. Keep an independent copy of important records and check the current app listing for device compatibility before purchase.
Publisher documentation describes data sharing/export, and Apple release history identifies CSV. Native Excel or PDF reports, exact current logging intervals, and identical export behavior on both operating systems are not promised. Neither the meter nor this app overview establishes an immutable audit trail, regulatory compliance, guaranteed background alarms or offsite safety monitoring. Check your recordkeeping procedure before relying on connected data.
Alternative format: Apera PH60 Waterproof Pocket pH Tester Kit (AI311). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.
No. pH and temperature measurement, button calibration, the stable-reading indicator and HOLD work on the tester. ZenTest is the separate route for logging and connected data management, not a requirement for ordinary measurements.
Choose PH60F-Z for wetted surfaces and controlled small volumes, or PH60S-Z for moist soft-solid sampling. PH60-Z is for aqueous immersion. Other probe shapes are sold separately.
Low-ionic-strength water can produce slow or unstable results with a general-purpose probe. A specialized electrode and controlled method may be necessary. Do not assume that adding electrolyte leaves the original sample unchanged.
Check fresh buffers, the selected buffer family, hydration, cleanliness and full sensor contact first. Er2 means confirmation came before stability. Clean and condition the probe, recalibrate, then check a fresh known buffer before deciding it needs replacement.
PH60-DE (AI3711-E) is the matching replacement. PH60-DE, PH60F-DE and PH60S-DE are supported pH alternatives, sold separately. Choose by sample type and recalibrate after fitting.
Optional ORP60-DA, AI3717-DA, replaces the pH probe for ORP. Do not substitute ORP60-DE. A conductivity probe is not a supported EC upgrade.
Tester with matching probe and cap, pH 4.00 and 7.00 buffers, calibration vials, 3M KCl, lanyard, case, instructions and four AAA batteries. Phones, sample props and alternate probes are not supplied.
Check buffers, cleanliness, hydration and connection; recalibrate and verify a known buffer. Warranty excludes routine wear, accidental damage and incorrect storage.
Review PH60-Z AI3711 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.
APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.