Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Default Title Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Default Title Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments

Apera PCO60-Z ZenTest pH, Conductivity and ORP Tester Kit

$268.00

    The combo tester plus its separate ORP60-DA head, with each measurement kept distinct.

    • PC60-Z meter with PC60-DE combo head
    • Separate ORP60-DA head included
    • EC range up to 20.00 mS/cm
    • Physical head change required for ORP

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PCO60-Z / AI3803

One meter. Two heads.
A deliberate change for ORP.

Bring pH, conductivity and ORP work into one carrying case without pretending they share a single sensing tip. PCO60-Z supplies a PC60-Z meter with the PC60-DE pH/EC/temperature combo head and a separate ORP60-DA platinum ORP head for a physical sensor change.

Choose this configuration for the included ORP head. TDS, salinity and resistivity derive from the combo head’s conductivity measurement. ORP is measured separately with ORP60-DA, not simultaneously through the pH/EC head.

PCO60-Z kit illustration showing PC60-Z meter, phone and separate ORP head
PCO60-Z supplies PC60-Z with PC60-DE plus separate ORP60-DA. Phone not included; pictured app and probe appearance are illustrative.
Which ZenTest kit fits my measurement?Click or tap to compare all seven measurement kitsClick or tap here to close the guide

Each card opens that kit page, not an upgrade for the current meter. Match the supplied head and supported measurements. Phones and additional probes are not included unless the exact kit contents say so.

Choose the right configuration.

The combo head handles pH and EC

PC60-DE combines a blue glass pH sensor with a double-junction reference, platinum-black conductivity rods and temperature sensing. It is the head for pH, EC and the EC-derived displays. Calibrate pH and conductivity separately rather than assuming one calibration covers every direct measurement.

The ORP head has its own role

ORP60-DA provides a platinum sensing element and ceramic reference junctions. Install it in place of PC60-DE for ORP; the meter automatically enters ORP mode. Do not assume the separate ORP head contains the combo head’s temperature sensor or provides temperature-compensated ORP.

Choose the packout, not a new meter

The instrument inside this kit is PC60-Z. The added ORP60-DA changes the supplied capability, not the basic pH or EC accuracy. On-meter measurement and calibration remain available without a phone, while compatible phone-connected functions provide a separate app workflow.

Know exactly what is supplied.

Included item Order contents
PCO60-Z kit PC60-Z meter with PC60-DE pH/EC/temperature combo head
ORP60-DA head Separate ORP head; exchange with PC60-DE for ORP measurements
pH buffers pH 4.00 and pH 7.00
3M KCl External probe conditioning solution
EC standards 1413 µS/cm and 12.88 mS/cm
Calibration vials For separate working portions of calibration solutions
Four AAA batteries Power for the tester
Carrying case and lanyard For transport and handling
Documentation Operating guidance
Manufacturer PCO60-Z case diagram labeled ORP60-DA with pH and conductivity standards
PCO60-Z case layout with the correctly identified ORP60-DA head. Photograph illustrates the kit, not exact current bottle volumes or appearance.
PCO60-Z meter and separate ORP60-DA head in carrying case
Closer case view for scale and organization. Separate ORP head sits above the standards; no 222 mV solution is included in this illustration.

Where this configuration fits.

Water treatment observations

Use pH and conductivity to characterize compatible water samples, then change heads for an ORP observation. ORP can support a defined process method, but it is not a direct disinfectant concentration, pathogen measurement or stand-alone proof of safe water.

Nutrient and freshwater solutions

Follow acidity and overall ionic strength with the combo head. TDS is calculated using a selectable factor, not a chemical inventory. The 10.00 ppt salinity ceiling excludes direct normal-seawater salinity testing even though the kit offers several display modes.

Multi-parameter teaching and checks

Show how different sensing elements answer different questions. Keep the head identity, units, calibration and sample treatment with each result. Results still depend on careful preparation.

Change the head for ORP.. One meter does not mean simultaneous sensing from one tip.
Sensor roles are separate. This diagram is a workflow guide, not a claim of simultaneous pH/EC/ORP acquisition.

Finish one measurement.
Change the head for the next.

Begin combo-head preparation with fresh standards. Start USA-series pH calibration at 7.00, then add suitable points without powering off. Supplied pH buffers are 4.00 and 7.00. For EC, begin with 1413 µS/cm and use 12.88 mS/cm for work above 2 mS/cm or when a check requires it. The recognized 84 µS/cm standard is separate.

Remove the cap, rinse and fully immerse the sensing area. Stir briefly to clear bubbles, then wait for stability. Keep original sample portions separate from any aliquot altered for pH stabilization. EC defaults to a 25 °C reference and 2.00%/°C compensation; the TDS factor defaults to 0.71 and adjusts from 0.40 to 1.00.

For ORP, follow the manual’s head-change procedure and replace PC60-DE with ORP60-DA. Keep the connector clean and dry, rinse the sensing end, stir gently in the sample and wait for the stable icon. Record the ORP result separately. A 222 mV reference solution is not included, and no unsupported on-meter ORP calibration routine is promised.

A closer look at the supplied sensor.

PC60-DE blue pH bulb and platinum-black conductivity rods
PC60-DE combines pH and conductivity sensing, not ORP. Manufacturer illustration; removable-shield appearance may differ.
ORP60-DA platinum ORP sensing element and ceramic junction
Separate ORP60-DA head included with PCO60-Z. Exchange it with PC60-DE for ORP; it is not ORP60-DE.

Care for the head in use.
Do not merge the routines.

For regular PC60-DE storage, maintain humidity with a few water droplets inside a tightly closed cap. Do not immerse the combo head in water for storage. Tap, RO, distilled and deionized water are not storage liquids for this probe; distilled or deionized water is appropriate for rinsing sample residue away.

For a dried or slow combo probe, external conditioning in 3M KCl for about two hours is specified. Never exceed 24 hours, because the conductivity sensor can be damaged. After more than a month unused, follow the manual’s 15-minute KCl preparation and recalibration instructions. The KCl bottle is not a user-refill instruction.

Handle the separate ORP head as its own electrode. Rinse after use and follow its accessory instructions for cleaning and conditioning; do not assume the combo probe’s complete storage method applies unchanged. Protect sensing surfaces and connectors. Replace a worn or damaged head with the exact compatible model.

Humidity, not immersion.. These instructions apply to the PC60-DE combo head.
Follow the exact combo manual. Do not apply a generic long pH soak to the conductivity sensor.
PC60-Z meter display and three front control buttons
PC60-Z meter controls handle standalone testing and calibration. The display is an illustrative reading.

Read the meter.
Know what is held.

Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.

Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.

Choose a connected workflow.
Keep its limits clear.

The tester measures and calibrates without a phone. Connect a compatible smartphone inside ZenTest, rather than treating operating-system PIN pairing as the measurement workflow. Bluetooth, required phone permissions and a nearby powered tester are needed for new connected readings. A smartphone is not included.

ZenTest offers Simple, Dial, Graph and Table views, with manual and timed recording, measurement/calibration records, and tools for notes, photos and location tagging. Available parameters still depend on the exact body and fitted head. Display choices cannot add pH or conductivity to an unsupported model.

Account and cloud functions depend on the compatible app, service and internet connection. Reviewing already saved records while disconnected is not continuous measurement acquisition outside Bluetooth range. Keep an independent copy of important records and check the current app listing for device compatibility before purchase.

Publisher documentation describes data sharing/export, and Apple release history identifies CSV. Native Excel or PDF reports, exact current logging intervals, and identical export behavior on both operating systems are not promised. Neither the meter nor this app overview establishes an immutable audit trail, regulatory compliance, guaranteed background alarms or offsite safety monitoring. Check your recordkeeping procedure before relying on connected data.

Official ZenTest app-store screenshot showing pH dial display
Official app-store pH display illustration, appropriate to the PC60-DE pH workflow. Interface may vary; no phone is included and this is not an ORP or EC screen.

Compare a standalone alternative.

Alternative format: Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.

PCO60-Z buyer questions

Is PCO60-Z a single all-parameter sensor?

No. It is a PC60-Z meter with two supplied heads: PC60-DE for pH/EC/temperature and ORP60-DA for ORP. The heads are physically exchanged, so pH, EC and ORP are not acquired simultaneously from one tip.

What does this kit add over PC60-Z?

It includes the separate ORP60-DA head. Standard PC60-Z supplies the combo head but sells ORP60-DA separately. The pH accuracy specification is unchanged.

Can I replace ORP60-DA with ORP60-DE?

Do not treat those names as interchangeable. ORP60-DE belongs to the dedicated ORP60-Z tester. The head specified for this PC60-Z-based combo configuration is ORP60-DA.

Is 222 mV ORP solution included?

No inclusion is promised. The supplied solutions are pH 4.00 and 7.00, EC 1413 µS/cm and 12.88 mS/cm, and 3M KCl. Purchase an appropriate ORP reference separately when your procedure requires one.

Why might TDS disagree with another tester?

Check conversion factor, units and compensation. At 1000 µS/cm, factor 0.71 reports 710 ppm while factor 0.50 reports 500 ppm. Calibrate conductivity rather than looking for a separate TDS calibration.

Can ORP tell me the chlorine concentration?

Not directly. ORP is a redox-potential reading affected by the sample chemistry and method. Use the appropriate chemical test when a disinfectant concentration or compliance result is required.

Can I work without a smartphone?

Yes. The meter provides standalone measurement and calibration controls. A compatible phone is for connected app functions and is not included. Saved measurement histories are not an internal meter-logger feature.

What batteries and warranty apply?

The tester uses four AAA batteries. The manufacturer’s formal warranty is two years for the instrument and six months for the probes from delivery, subject to its terms, normal-wear limitations and other exclusions.

Confirm the exact item before ordering.

Review PCO60-Z AI3803 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.

Back to price and ordering ↑
    SpecificationDetail
    pH range-2.00 to 16.00 pH
    pH resolution0.01 or 0.1 pH selectable
    pH accuracy±0.01 pH ±1 digit
    pH calibration1 to 3 points
    Conductivity range0 to 20.00 mS/cm (20,000 µS/cm)
    Conductivity resolution0.1 µS/cm / 1 µS/cm / 0.01 mS/cm
    Conductivity accuracy±1% full scale
    EC calibration1 to 3 points: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
    TDS range0.1 ppm to 10.00 ppt
    TDS factor0.40 to 1.00; default 0.71
    Salinity range0 to 10.00 ppt
    Resistivity range50 Ω·cm to 20 MΩ·cm
    Temperature range0 to 50 °C (32 to 122 °F)
    Temperature accuracy±0.5 °C
    EC reference temperature15 to 30 °C; default 25 °C
    EC temperature coefficient0 to 9.99%/°C; default 2.00%/°C
    PowerFour AAA batteries
    Instrument dimensions40 × 40 × 178 mm
    Manufacturer warrantyTwo years instrument; six months probe(s), from delivery; terms apply
    ORP range with ORP60-DA-1000 to +1000 mV
    ORP resolution1 mV
    ORP accuracy±0.2% full scale
    Warranty2-year instrument / 6-month probe limited warranty; terms and exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3803
    Blue Tiger SKUBTS-AI3803
    Order unit1 exact ZenTest tester kit
    Order contentsPCO60-Z kit: PC60-Z meter with PC60-DE pH/EC/temperature combo head; ORP60-DA head: Separate ORP head; exchange with PC60-DE for ORP measurements; pH buffers: pH 4.00 and pH 7.00; 3M KCl: External probe conditioning solution; EC standards: 1413 µS/cm and 12.88 mS/cm; Calibration vials: For separate working portions of calibration solutions; Four AAA batteries: Power for the tester; Carrying case and lanyard: For transport and handling; Documentation: Operating guidance

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PCO60-Z official documents

    Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.