Apera ORP60-DA ORP Add-on Probe for Compatible ZenTest Testers (AI3717-DA)

$69.00

    The documented ORP add-on for compatible pH and multiparameter ZenTest bodies.

    • For PH60-Z, PH60F-Z, PH60S-Z, PC60-Z and PCO60-Z
    • Platinum ORP sensing element
    • Double-junction structure
    • For general water solution ORP testing

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / ORP60-DA / AI3717-DA

Add ORP measurement to a compatible ZenTest body

The ORP60-DA is a platinum, double-junction ORP probe for PH60-Z, PH60F-Z, PH60S-Z, PC60-Z and PCO60-Z. Swap to this electrode for redox measurement in general water solutions; it is distinct from the ORP60-DE dedicated to ORP60-Z.

ORP60-DA replacement probe with white body and exposed sensing end
ORP60-DA replacement probe. manufacturer-supplied product photograph.
Which tester does this probe fit?

CURRENT PROBE: ORP60-DA

These are selected compatible tester bodies, not items included with this replacement probe. See the complete compatibility table below.

Why choose this replacement probe?

ORP add-on role

Install the ORP60-DA on a documented compatible body when you need redox measurement instead of the original probe’s measurement function.

Platinum sensing element

The platinum ORP sensor measures oxidation-reduction potential in general water solutions.

Double-junction design

Apera specifies double-junction construction for this ORP electrode.

Separate from ORP60-DE

The correct model depends on the tester body. ORP60-DE is the exclusive dedicated replacement for ORP60-Z, not this add-on.

Check the exact tester model before ordering.

Compatible tester Role and limits
PH60-Z ORP add-on/replacement. Named on the exact ORP60-DA listing.
PH60F-Z ORP add-on/replacement. Named on the exact ORP60-DA listing; use for water ORP testing, not as a flat-surface pH sensor.
PH60S-Z ORP add-on/replacement. Named on the exact ORP60-DA listing; use for water ORP testing, not as a spear pH sensor.
PC60-Z ORP add-on/replacement. ORP60-DA is named in the ORP measurement and replacement sections of its manual.
PCO60-Z ORP add-on/replacement. The parent manual identifies ORP60-DA in the kit contents and ORP instructions.

Compatibility applies to the named tester body and stated sensing role. A shared connector or a similar probe name does not make every 60-series sensor interchangeable. Tester display, connectivity, app and data functions belong to the compatible tester, not this replacement probe.

Fit the correct probe, then prepare for measurement

Check your exact tester model before fitting the probe. Remove the cap, unscrew the probe ring and unplug the original probe. Align the ORP60-DA correctly, insert it and tighten the ring according to your host instructions.

The PC60-Z manual describes automatic switching to ORP measurement mode after installation of ORP60-DA. Follow the instructions for your own host rather than assuming identical controls across every compatible model.

Rinse the probe in pure water, shake off excess water, dip it into the water sample and stir briefly. Hold it still and record the redox reading only after the host indicates stability.

Match the sensor to the sample.

ORP testing with a compatible pH tester

Use PH60-Z, PH60F-Z or PH60S-Z with this add-on for general water redox measurement.

ORP mode on a multiparameter tester

Fit ORP60-DA to PC60-Z or PCO60-Z when ORP is needed; the original pH/EC sensor is not itself an ORP electrode.

What this order supplies

Included item Details
ORP60-DA replacement probe Replacement sensing module only; compatible tester required. No additional accessories are promised by this package.

Care for the sensor you are using

Rinse the ORP sensing end before and after measurement to avoid carrying residue between samples. Protect the platinum sensing element from knocks and keep the cap fitted between uses.

Follow the compatible host’s ORP care instructions for cleaning and conditioning. Do not apply pH-buffer calibration or treat the platinum sensor as a glass pH bulb. Likewise, do not transfer the conductivity sensor’s care requirements to this ORP-only electrode.

The cited replacement instructions do not establish an electrolyte-refill procedure for ORP60-DA. Storage or soaking solution is for external probe care, not permission to open and refill the electrode.

ORP60-DA buyer questions

Which testers are documented for ORP60-DA?

PH60-Z, PH60F-Z, PH60S-Z, PC60-Z and PCO60-Z. The PCO60-Z manual specifically identifies ORP60-DA.

Is this the dedicated ORP60-Z replacement?

No. Use ORP60-DE for the dedicated ORP60-Z replacement role.

Does ORP60-DA have a built-in temperature sensor?

The cited exact-product listing does not specify one. Do not transfer the explicit built-in-temperature claim from ORP60-DE to ORP60-DA.

Can it measure pH while installed?

No. This is an ORP electrode. Swap back to an appropriate pH or combination probe when you need those measurements.

Can it be used for spear or flat-surface pH testing?

No. PH60S-Z and PH60F-Z compatibility concerns their tester bodies; this ORP probe is intended for general water solutions.

Does the probe provide app or logging hardware?

This listing supplies the sensing probe, not a meter or data-logging device. Controls, connectivity and data functions depend on the compatible host and its software.

Can I refill the electrode with storage solution?

No refill procedure is established by the cited sources. Use only the external care procedures specified for your compatible host and probe.

What warranty applies?

Six-month limited electrode warranty from delivery against defects in materials and workmanship attributable to Apera. Excludes accidental damage, improper use, normal wear, transportation or storage issues, failure to follow instructions, unauthorized repair or modification, and external causes.

    SpecificationORP60-DA
    ModelORP60-DA
    Manufacturer SKUAI3717-DA
    Probe typeORP add-on/replacement electrode
    Sensing elementPlatinum
    JunctionDouble junction
    Compatible testersPH60-Z, PH60F-Z, PH60S-Z, PC60-Z, PCO60-Z
    Temperature sensorNot specified for ORP60-DA in the cited exact-product listing
    Electrode warrantySix months from delivery; limited warranty

    Ordering Information

    Order detailConfiguration
    Manufacturer catalogAI3717-DA
    Store SKUBTS-AI3717-DA
    Order unitOne ORP60-DA replacement probe
    Included suppliesORP60-DA replacement probe: Replacement sensing module only; compatible tester required. No additional accessories are promised by this package.
    Compatible bodiesPH60-Z, PH60F-Z, PH60S-Z, PC60-Z, PCO60-Z

    Apera Manufacturer Limited Electrode Warranty

    Six months from delivery for qualifying defects in materials and workmanship attributable to Apera, subject to its stated terms. The parent tester warranty does not extend this probe coverage.

    Exclusions include accidental damage, improper use, normal wear, transportation or storage issues, failure to follow instructions, unauthorized repair or modification, and external causes. Follow the exact probe and compatible tester instructions for installation, calibration and care.

    ORP60-DA instructions and compatible tester manuals

    Each card opens a verified official PDF. Parent-tester manuals cover the stated body and its procedures; they are not standalone specifications for this probe. Regional documents are identified, and warranty or compatibility wording can differ from US documentation. Use this listing’s specific compatibility notes.

Questions about a product? Ask us here.