Give us a call at (833)928-4437
The documented ORP add-on for compatible pH and multiparameter ZenTest bodies.
Preparing Quote Cart. Your shopping cart stays unchanged.
APERA INSTRUMENTS / ORP60-DA / AI3717-DA
The ORP60-DA is a platinum, double-junction ORP probe for PH60-Z, PH60F-Z, PH60S-Z, PC60-Z and PCO60-Z. Swap to this electrode for redox measurement in general water solutions; it is distinct from the ORP60-DE dedicated to ORP60-Z.
CURRENT PROBE: ORP60-DA
These are selected compatible tester bodies, not items included with this replacement probe. See the complete compatibility table below.
ORP add-on/replacement
Install the ORP60-DA on a documented compatible body when you need redox measurement instead of the original probe’s measurement function.
The platinum ORP sensor measures oxidation-reduction potential in general water solutions.
Apera specifies double-junction construction for this ORP electrode.
The correct model depends on the tester body. ORP60-DE is the exclusive dedicated replacement for ORP60-Z, not this add-on.
Compatibility applies to the named tester body and stated sensing role. A shared connector or a similar probe name does not make every 60-series sensor interchangeable. Tester display, connectivity, app and data functions belong to the compatible tester, not this replacement probe.
Check your exact tester model before fitting the probe. Remove the cap, unscrew the probe ring and unplug the original probe. Align the ORP60-DA correctly, insert it and tighten the ring according to your host instructions.
The PC60-Z manual describes automatic switching to ORP measurement mode after installation of ORP60-DA. Follow the instructions for your own host rather than assuming identical controls across every compatible model.
Rinse the probe in pure water, shake off excess water, dip it into the water sample and stir briefly. Hold it still and record the redox reading only after the host indicates stability.
Use PH60-Z, PH60F-Z or PH60S-Z with this add-on for general water redox measurement.
Fit ORP60-DA to PC60-Z or PCO60-Z when ORP is needed; the original pH/EC sensor is not itself an ORP electrode.
Rinse the ORP sensing end before and after measurement to avoid carrying residue between samples. Protect the platinum sensing element from knocks and keep the cap fitted between uses.
Follow the compatible host’s ORP care instructions for cleaning and conditioning. Do not apply pH-buffer calibration or treat the platinum sensor as a glass pH bulb. Likewise, do not transfer the conductivity sensor’s care requirements to this ORP-only electrode.
The cited replacement instructions do not establish an electrolyte-refill procedure for ORP60-DA. Storage or soaking solution is for external probe care, not permission to open and refill the electrode.
PH60-Z, PH60F-Z, PH60S-Z, PC60-Z and PCO60-Z. The PCO60-Z manual specifically identifies ORP60-DA.
No. Use ORP60-DE for the dedicated ORP60-Z replacement role.
The cited exact-product listing does not specify one. Do not transfer the explicit built-in-temperature claim from ORP60-DE to ORP60-DA.
No. This is an ORP electrode. Swap back to an appropriate pH or combination probe when you need those measurements.
No. PH60S-Z and PH60F-Z compatibility concerns their tester bodies; this ORP probe is intended for general water solutions.
This listing supplies the sensing probe, not a meter or data-logging device. Controls, connectivity and data functions depend on the compatible host and its software.
No refill procedure is established by the cited sources. Use only the external care procedures specified for your compatible host and probe.
Six-month limited electrode warranty from delivery against defects in materials and workmanship attributable to Apera. Excludes accidental damage, improper use, normal wear, transportation or storage issues, failure to follow instructions, unauthorized repair or modification, and external causes.
Apera Manufacturer Limited Electrode Warranty
Six months from delivery for qualifying defects in materials and workmanship attributable to Apera, subject to its stated terms. The parent tester warranty does not extend this probe coverage.
Exclusions include accidental damage, improper use, normal wear, transportation or storage issues, failure to follow instructions, unauthorized repair or modification, and external causes. Follow the exact probe and compatible tester instructions for installation, calibration and care.
Each card opens a verified official PDF. Parent-tester manuals cover the stated body and its procedures; they are not standalone specifications for this probe. Regional documents are identified, and warranty or compatibility wording can differ from US documentation. Use this listing’s specific compatibility notes.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.