Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Default Title Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Default Title Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments
Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit Smart pH/Conductivity Tester Apera Instruments

Apera PC60-Z ZenTest pH and Conductivity Combo Tester Kit

$199.00

    pH and conductivity together, without confusing calculated parameters with extra sensors.

    • PC60-DE pH/EC/temperature combo head included
    • pH accuracy ±0.01 pH ±1 digit
    • EC range 0 to 20.00 mS/cm
    • Optional ORP60-DA head is sold separately

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PC60-Z / AI3719

Two direct measurements.
One practical pocket workflow.

Check pH and conductivity with the supplied PC60-DE combo head, then view EC-derived TDS, salinity and resistivity as needed. PC60-Z brings a double-junction pH reference, platinum-black conductivity sensor and temperature sensing into one replaceable head for compatible aqueous samples.

Choose PC60-Z for pH plus EC work with standalone meter operation and optional phone-connected functions. The supplied combo head is not an ORP sensor. ORP measurement requires a separately purchased ORP60-DA head and a physical head change.

Apera PC60-Z tester with PC60-DE combo head
PC60-Z with its supplied combo head. Manufacturer photographs are illustrations; probe-shield appearance may vary.
Which ZenTest kit fits my measurement?Click or tap to compare all seven measurement kitsClick or tap here to close the guide

Each card opens that kit page, not an upgrade for the current meter. Match the supplied head and supported measurements. Phones and additional probes are not included unless the exact kit contents say so.

Choose the right configuration.

A head with distinct sensing elements

The blue glass pH bulb and platinum-black conductivity rods have different jobs. Temperature sensing supports the meter’s compensation functions. This combined construction reduces the equipment to carry, but each direct measurement still needs its own calibration routine and appropriate sample handling.

Useful derived results, clearly defined

TDS, salinity and resistivity are derived from conductivity. The TDS factor adjusts from 0.40 to 1.00, with 0.71 as the default. Record the factor when comparing ppm results, and do not interpret the display as identification of nutrients, contaminants or individual ions.

A portable routine that can grow

Measure and calibrate using the meter’s own buttons when a phone is unnecessary. For ORP work later, fit the optional ORP60-DA instead of the combo head. It is a change of sensor, not a software unlock or an additional simultaneous measurement from PC60-DE.

Know exactly what is supplied.

Included item Order contents
PC60-Z kit PC60-Z meter with PC60-DE pH/EC/temperature combo head
pH buffers pH 4.00 and pH 7.00
3M KCl External probe conditioning solution
EC standards 1413 µS/cm and 12.88 mS/cm
Calibration vials For separate working portions of calibration solutions
Four AAA batteries Power for the tester
Carrying case and lanyard For transport and handling
Documentation Operating guidance
PC60-Z standing in the upper section of its carrying case
Meter-in-case context only, not an exhaustive current packout or a vial-count promise. Manufacturer photograph; appearance may vary.

Where this configuration fits.

Nutrient and dilution water

Follow both acidity and ionic strength in compatible nutrient solutions. pH and EC answer different questions, so test both rather than assuming a good result in one means the other is correct. Stay within the stated ranges.

General freshwater checks

Compare source water, prepared solutions and freshwater process samples. The portable format is useful where a bench station is inconvenient. Neither pH nor EC-derived TDS by itself establishes potability, contamination identity or a complete water-quality assessment.

Teaching and routine aqueous testing

Demonstrate calibration, temperature settings and the relationship between conductivity and TDS. For very low-conductivity water, pH can take longer to settle; use a suitable method rather than treating a slow response as an automatic instrument fault.

Two calibrations. One head.. PC60-DE combines pH, conductivity and temperature sensing.
Method summary for the supplied PC60-DE head. TDS, salinity and resistivity follow EC calibration.

Calibrate pH and EC.
Keep the sample unchanged.

Use fresh portions of standards and rinse between them. Start pH calibration at 7.00 in the USA buffer series, then add an appropriate second or third point without switching off. The supplied pH buffers are 4.00 and 7.00. Five recognized buffer values do not mean five calibration points or five bottles supplied.

Calibrate conductivity separately, beginning with 1413 µS/cm. Use 12.88 mS/cm for higher-conductivity work above 2 mS/cm or when a check indicates it is needed. The supported 84 µS/cm standard is not supplied. Fully immerse the sensing area, release bubbles with a brief stir and wait for the stable icon before reading.

Compare like settings: EC defaults are 25 °C reference temperature and 2.00%/°C compensation. Check TDS factor and ppm versus ppt units. If a low-ionic-strength pH method adds KCl to stabilize the reading, use a separate aliquot for original-sample EC, TDS, salinity or resistivity because the addition changes conductivity.

A closer look at the supplied sensor.

PC60-DE blue pH bulb and platinum-black conductivity rods
PC60-DE combines pH and conductivity sensing, not ORP. Manufacturer illustration; removable-shield appearance may differ.

Humidity for storage.
Limited KCl conditioning.

Rinse away sample residue after testing. For regular combo-head storage, a few water droplets inside the tightly closed cap maintain humidity. This is not an instruction to immerse the sensing tip in water. Never store the combo probe in tap, RO, distilled or deionized water; pure water is for rinsing.

If the combo probe becomes dry or slow, condition it externally in 3M KCl for about two hours. Never exceed 24 hours, because prolonged soaking can damage the conductivity sensor. The supplied KCl is an external soaking solution, not evidence of a user-refill procedure or a reason to open the probe.

After more than a month unused, follow the manual’s 15-minute KCl preparation and recalibration routine. For difficult contamination, follow the shield-removal and cleaning instructions, avoid rough treatment of the glass bulb and observe the same 24-hour conditioning ceiling. Keep electrical contacts clean and dry when replacing the head.

Humidity, not immersion.. These instructions apply to the PC60-DE combo head.
Follow the exact combo manual. Do not apply a generic long pH soak to the conductivity sensor.
PC60-Z meter display and three front control buttons
PC60-Z meter controls handle standalone testing and calibration. The display is an illustrative reading.

Read the meter.
Know what is held.

Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.

Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.

Rear view of PC60-Z transparent body and battery compartment
Rear construction view. PC60-Z uses four AAA batteries; follow the manual for replacement and keep the compartment dry.

Choose a connected workflow.
Keep its limits clear.

The tester measures and calibrates without a phone. Connect a compatible smartphone inside ZenTest, rather than treating operating-system PIN pairing as the measurement workflow. Bluetooth, required phone permissions and a nearby powered tester are needed for new connected readings. A smartphone is not included.

ZenTest offers Simple, Dial, Graph and Table views, with manual and timed recording, measurement/calibration records, and tools for notes, photos and location tagging. Available parameters still depend on the exact body and fitted head. Display choices cannot add pH or conductivity to an unsupported model.

Account and cloud functions depend on the compatible app, service and internet connection. Reviewing already saved records while disconnected is not continuous measurement acquisition outside Bluetooth range. Keep an independent copy of important records and check the current app listing for device compatibility before purchase.

Publisher documentation describes data sharing/export, and Apple release history identifies CSV. Native Excel or PDF reports, exact current logging intervals, and identical export behavior on both operating systems are not promised. Neither the meter nor this app overview establishes an immutable audit trail, regulatory compliance, guaranteed background alarms or offsite safety monitoring. Check your recordkeeping procedure before relying on connected data.

Official ZenTest app-store screenshot showing pH dial display
Official app-store pH display illustration, appropriate to the PC60-DE pH workflow. Interface may vary; no phone is included and this is not an ORP or EC screen.

Compare a standalone alternative.

Alternative format: Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.

PC60-Z buyer questions

Does the supplied head measure ORP?

No. PC60-DE measures pH, conductivity and temperature. ORP requires optional ORP60-DA, sold separately, fitted in place of the combo head. A millivolt label does not make a pH electrode an ORP sensor.

How does this differ from PCO60-Z?

PCO60-Z includes the PC60-Z meter and combo head plus a separate ORP60-DA head. This PC60-Z kit does not include that extra ORP head. Both configurations require a physical head change for ORP.

Is ORP60-DE the same accessory?

No. Do not substitute the ORP60-DE used by the dedicated ORP60-Z tester. The specified ORP upgrade for PC60-Z is ORP60-DA. Match the exact accessory designation before ordering.

Why can two meters show different TDS?

A different conversion factor can produce different ppm from the same EC. At 1000 µS/cm, factor 0.71 gives 710 ppm and factor 0.50 gives 500 ppm. Compare settings before diagnosing a fault.

Can I use it for normal seawater salinity?

Not directly: the salinity ceiling is 10.00 ppt, below normal seawater, and EC is limited to 20.00 mS/cm. Select a different range for ordinary marine salinity work.

Does calibration require the app?

No. The meter supports standalone measurement and calibration. Phone-connected app functions are separate, and no smartphone is supplied. The meter itself is not an internal measurement-history logger.

What care solution belongs in the kit?

The kit includes 3M KCl for external combo-probe conditioning, alongside pH 4.00/7.00 buffers and the two EC standards. Do not treat KCl as a pH calibration buffer or an internal refill instruction.

What is the formal warranty?

The instrument has a two-year manufacturer warranty and the probe a six-month warranty from delivery, subject to terms and exclusions. Normal wear, misuse and accidental damage are not a guaranteed replacement entitlement.

Confirm the exact item before ordering.

Review PC60-Z AI3719 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.

Back to price and ordering ↑
    SpecificationDetail
    pH range-2.00 to 16.00 pH
    pH resolution0.01 or 0.1 pH selectable
    pH accuracy±0.01 pH ±1 digit
    pH calibration1 to 3 points
    Conductivity range0 to 20.00 mS/cm (20,000 µS/cm)
    Conductivity resolution0.1 µS/cm / 1 µS/cm / 0.01 mS/cm
    Conductivity accuracy±1% full scale
    EC calibration1 to 3 points: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
    TDS range0.1 ppm to 10.00 ppt
    TDS factor0.40 to 1.00; default 0.71
    Salinity range0 to 10.00 ppt
    Resistivity range50 Ω·cm to 20 MΩ·cm
    Temperature range0 to 50 °C (32 to 122 °F)
    Temperature accuracy±0.5 °C
    EC reference temperature15 to 30 °C; default 25 °C
    EC temperature coefficient0 to 9.99%/°C; default 2.00%/°C
    PowerFour AAA batteries
    Instrument dimensions40 × 40 × 178 mm
    Manufacturer warrantyTwo years instrument; six months probe(s), from delivery; terms apply
    Warranty2-year instrument / 6-month probe limited warranty; terms and exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3719
    Blue Tiger SKUBTS-AI3719
    Order unit1 exact ZenTest tester kit
    Order contentsPC60-Z kit: PC60-Z meter with PC60-DE pH/EC/temperature combo head; pH buffers: pH 4.00 and pH 7.00; 3M KCl: External probe conditioning solution; EC standards: 1413 µS/cm and 12.88 mS/cm; Calibration vials: For separate working portions of calibration solutions; Four AAA batteries: Power for the tester; Carrying case and lanyard: For transport and handling; Documentation: Operating guidance

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PC60-Z official documents

    Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat