Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Default Title Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Default Title Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments
Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit Smart Conductivity Tester Apera Instruments

Apera EC60-Z ZenTest Conductivity, TDS and Salinity Tester Kit

$149.00

    A focused EC workflow, with clear conversion settings and a replaceable sensing head.

    • EC up to 20.00 mS/cm, not 200 mS/cm
    • TDS factor adjustable from 0.40 to 1.00
    • 1413 µS/cm and 12.88 mS/cm standards supplied
    • Measure and calibrate without a smartphone

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / EC60-Z / AI3718

One conductivity sensor.
Several useful ways to read water.

Follow nutrient strength, dilution and changes in dissolved ionic content with a pocket tester built around conductivity. EC60-Z combines the replaceable EC60-DE conductivity/temperature head with on-meter measurement and calibration, plus Bluetooth connectivity for a compatible phone when your workflow calls for ZenTest.

Choose this kit when conductivity is the primary measurement. TDS, salinity and resistivity are related readings derived from EC, not separate chemical analyses. EC60-Z does not measure pH or ORP and is not offered here as a platform for those upgrades.

Apera EC60-Z conductivity tester with EC60-DE head
EC60-Z with conductivity/temperature head. Manufacturer photograph illustrates the product; appearance may vary.
Which ZenTest kit fits my measurement?Click or tap to compare all seven measurement kitsClick or tap here to close the guide

Each card opens that kit page, not an upgrade for the current meter. Match the supplied head and supported measurements. Phones and additional probes are not included unless the exact kit contents say so.

Choose the right configuration.

Start with the direct measurement

The platinum-black conductivity sensor measures the solution’s electrical conductance, while the built-in temperature sensor supports compensation. EC is the useful starting point when comparing results across instruments. Its stated accuracy is ±1% of full scale, not ±1% of each reading.

Make ppm comparisons meaningful

The adjustable TDS factor lets you match an established reporting convention. At 1000 µS/cm, the factory factor of 0.71 gives 710 ppm; a factor of 0.50 gives 500 ppm. Those different numbers can describe the same conductivity, so record the factor alongside the result.

Keep the instrument in service

The EC60-DE head is replaceable without replacing the entire tester. The meter’s display and buttons handle everyday tests, calibration and hold functions independently of a phone. A carrying case keeps the instrument and calibration supplies together between sampling locations.

Know exactly what is supplied.

Included item Order contents
EC60-Z kit EC60-Z meter with EC60-DE conductivity/temperature head
EC standards 1413 µS/cm and 12.88 mS/cm
Calibration vials For separate working portions of calibration solutions
Four AAA batteries Power for the tester
Carrying case and lanyard For transport and handling
Documentation Operating guidance
EC60-Z meter in its carrying case with conductivity calibration supplies
Manufacturer case photograph for context, not a promise of exact stock appearance or bottle volumes. The specified batteries are four AAA.

Where this configuration fits.

Nutrient-solution checks

Compare feed solution and dilution water within the measurement range. Use conductivity to follow overall ionic strength rather than expecting a reading to identify individual nutrients, their ratios or a specific deficiency.

Freshwater and rinse monitoring

Track changes between source water, process water and rinses using consistent sample handling. EC-derived TDS is an estimate, not a direct count of all dissolved substances or a drinking-water safety assessment.

Lower-salinity aqueous processes

Use the salinity display for compatible solutions up to 10.00 ppt. That ceiling is below normal seawater salinity, so this is not the choice for direct marine-aquarium or ordinary seawater salinity testing.

Calibrate EC. Then measure.. Use clean working portions and rinse between solutions.
Method summary based on the EC60-Z manual; consult the full instructions before use.

Calibrate the EC.
Then compare like with like.

Prepare clean portions of the supplied standards. In conductivity mode, begin with 1413 µS/cm; use 12.88 mS/cm when working above 2 mS/cm or when a check shows the need. The meter also recognizes 84 µS/cm for low-range calibration, but that standard is purchased separately. Do not pour used portions back into the stock bottle.

Remove the cap, rinse the probe and shake off excess water. Fully immerse the sensing area, stir briefly to release trapped bubbles, then hold still and wait for the stable-reading icon. Rinse between standards and samples. Use a clean vessel with enough sample to cover the sensors rather than trying to measure a shallow film.

Check the units and compensation settings before comparing results. The EC reference temperature defaults to 25 °C and the coefficient to 2.00%/°C; both are adjustable. TDS, salinity and resistivity follow EC calibration. There is no separate TDS calibration or invented zero-EC calibration step to perform.

A closer look at the supplied sensor.

EC60-DE white conductivity head and exposed black sensing rods
Conductivity head detail. This is not a pH glass electrode or an ORP upgrade.

Clean conductivity rods.
No pH storage routine required.

After each measurement, rinse with distilled or deionized water to remove residue. The EC60-DE has conductivity rods rather than a pH glass bulb. Do not transfer a combo pH probe’s KCl conditioning or storage directions to this sensor simply because the housings look similar.

For a sensor that has been unused, the manual gives conditioning options of 5 to 10 minutes in 12.88 mS/cm standard or 1 to 2 hours in tap water before use. These are preparation steps, not an instruction to leave the probe immersed indefinitely. Rinse before calibration or the next sample.

If the black rods become stained, gently clean them with a soft brush in warm water containing detergent or alcohol, following the manual. For an unexpected zero or unstable reading, first check immersion, bubbles, cleanliness, damage and fresh standard. Recondition and recalibrate before treating the result as a sample change.

EC care is not pH care.. Rinse the conductivity sensor after each measurement.
Preparation and cleaning for EC60-DE. These are not instructions for indefinite immersion or KCl storage.
Same EC. Different ppm.. A conversion factor changes the TDS number, not the measured EC.
Illustrative calculation, not a sample test. TDS factor is adjustable from 0.40 to 1.00.
EC60-Z display and MEAS MODE CAL buttons
Use the meter controls for standalone measurement and calibration. The displayed reading is illustrative.

Read the meter.
Know what is held.

Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.

Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.

Choose a connected workflow.
Keep its limits clear.

The tester measures and calibrates without a phone. Connect a compatible smartphone inside ZenTest, rather than treating operating-system PIN pairing as the measurement workflow. Bluetooth, required phone permissions and a nearby powered tester are needed for new connected readings. A smartphone is not included.

ZenTest offers Simple, Dial, Graph and Table views, with manual and timed recording, measurement/calibration records, and tools for notes, photos and location tagging. Available parameters still depend on the exact body and fitted head. Display choices cannot add pH or conductivity to an unsupported model.

Account and cloud functions depend on the compatible app, service and internet connection. Reviewing already saved records while disconnected is not continuous measurement acquisition outside Bluetooth range. Keep an independent copy of important records and check the current app listing for device compatibility before purchase.

Publisher documentation describes data sharing/export, and Apple release history identifies CSV. Native Excel or PDF reports, exact current logging intervals, and identical export behavior on both operating systems are not promised. Neither the meter nor this app overview establishes an immutable audit trail, regulatory compliance, guaranteed background alarms or offsite safety monitoring. Check your recordkeeping procedure before relying on connected data.

Compare a standalone alternative.

Alternative format: Apera EC60 Conductivity/TDS/Salinity Tester Kit (AI314). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.

EC60-Z buyer questions

Can EC60-Z measure pH or accept an ORP head?

No supported pH or ORP upgrade is claimed for EC60-Z. Its documented replacement is EC60-DE. Choose a suitable combo configuration if those measurements are part of your work.

Are TDS and salinity independent measurements?

No. Both are calculated from conductivity. The TDS factor is adjustable, while the salinity conversion uses a fixed factor. Neither mode identifies the dissolved ions or proves water safety.

Which calibration solutions are included?

The kit supplies 1413 µS/cm and 12.88 mS/cm conductivity standards. The supported 84 µS/cm standard is not included. Choose additional standards to suit the range you actually measure.

Why does my other meter show different ppm?

First compare EC, then check each meter’s TDS factor, ppm versus ppt units and temperature-compensation settings. A conversion mismatch can explain different ppm without either instrument being faulty.

Do I need a phone for ordinary testing?

No. Measurement, calibration and hold are available on the meter. ZenTest is the separate phone-connected route for app functions; the meter does not provide an internal measurement-history logger.

Is it suitable for normal seawater?

Not for direct normal-seawater salinity testing. Its salinity limit is 10.00 ppt and conductivity limit is 20.00 mS/cm. Check both limits against the intended sample before choosing the tester.

What batteries does it use?

Four AAA batteries are supplied. Follow the manual’s installation directions and keep the battery compartment dry. The correct battery specification is AAA, not AA.

What warranty applies to the tester and head?

The manufacturer’s formal warranty is two years for the instrument and six months for the probe from delivery, subject to its terms. Damage, misuse and normal wear are not a promise of free replacement.

Confirm the exact item before ordering.

Review EC60-Z AI3718 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.

Back to price and ordering ↑
    SpecificationDetail
    Conductivity range0 to 20.00 mS/cm (20,000 µS/cm)
    Conductivity resolution0.1 µS/cm / 1 µS/cm / 0.01 mS/cm
    Conductivity accuracy±1% full scale
    EC calibration1 to 3 points: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
    TDS range0.1 ppm to 10.00 ppt
    TDS factor0.40 to 1.00; default 0.71
    Salinity range0 to 10.00 ppt
    Resistivity range50 Ω·cm to 20 MΩ·cm
    Temperature range0 to 50 °C (32 to 122 °F)
    Temperature accuracy±0.5 °C
    EC reference temperature15 to 30 °C; default 25 °C
    EC temperature coefficient0 to 9.99%/°C; default 2.00%/°C
    PowerFour AAA batteries
    Instrument dimensions40 × 40 × 178 mm
    Manufacturer warrantyTwo years instrument; six months probe(s), from delivery; terms apply
    Warranty2-year instrument / 6-month probe limited warranty; terms and exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3718
    Blue Tiger SKUBTS-AI3718
    Order unit1 exact ZenTest tester kit
    Order contentsEC60-Z kit: EC60-Z meter with EC60-DE conductivity/temperature head; EC standards: 1413 µS/cm and 12.88 mS/cm; Calibration vials: For separate working portions of calibration solutions; Four AAA batteries: Power for the tester; Carrying case and lanyard: For transport and handling; Documentation: Operating guidance

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    EC60-Z official documents

    Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat