Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH60F-Z ZenTest Flat pH Tester Kit Default Title Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Default Title Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments
Apera PH60F-Z ZenTest Flat pH Tester Kit Smart pH Tester Apera Instruments

Apera PH60F-Z ZenTest Flat pH Tester Kit

$170.00

    Flat-membrane pH testing for wetted surfaces and controlled small volumes.

    • PH60F-DE flat glass pH/temperature probe
    • Small-volume method: at least 0.5 mL; flat-bottom vessel ID ≤19 mm
    • 1-3 calibration points; ±0.01 pH ±1 digit stated accuracy
    • Standalone readings; optional connected ZenTest workflow

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / PH60F-Z / AI3715

Flat contact.
A controlled small-sample method.

Choose Apera PH60F-Z for wetted surfaces and controlled small-volume liquids. The PH60F-DE flat glass membrane changes how you contact the sample, while pH and temperature remain available directly on the tester.

AI3715 is for wet analytical contact, not dry surfaces or arbitrary droplets. Button calibration works independently; Bluetooth supports a separate ZenTest data workflow.

Apera PH60F-Z pH tester beside an illustrative ZenTest phone screen
Tester and its supplied pH probe shown with a smartphone illustration. Phone is not included; app appearance may vary.
Which ZenTest kit fits my measurement?Click or tap to compare all seven measurement kitsClick or tap here to close the guide

Each card opens that kit page, not an upgrade for the current meter. Match the supplied head and supported measurements. Phones and additional probes are not included unless the exact kit contents say so.

Choose the right configuration.

A flat face with a defined method

PH60F-DE combines a flat glass membrane and temperature sensor. Both the sensing surface and reference junction need aqueous contact. Flat geometry changes sample presentation, not the need for calibration and wetting.

Calibrate where you measure

Automatic recognition supports 1-3 calibration points. Start at neutral, then select standards for your sample range. The default 0.01 pH resolution is a display increment, not guaranteed sample accuracy.

Useful on its own

Measure, calibrate and use HOLD without a phone. Correctly assembled, the IP67 enclosure floats. Seat caps and connections securely; protect the glass from impact.

Know exactly what is supplied.

Included item Order contents
PH60F-Z tester With PH60F-DE pH probe and protective/soaking cap.
Calibration buffers pH 4.00 and 7.00; bottle volumes not specified.
Calibration vials For separate working portions of buffer.
3M KCl storage solution For probe storage and conditioning as instructed.
Four AAA batteries Pull the battery insulation slip before first use.
Carrying case and lanyard Keep the tester and routine supplies together.
Instructions Setup, calibration, measurement and care guidance.
PH60F-Z carrying case with tester, buffers and routine accessories
Manufacturer kit illustration showing the tester and routine supplies. Packaging may vary; use the written kit list rather than the image to identify included items. No bottle volume or vial count is specified.

Where this configuration fits.

Paper, fabric and leather

Wet the test area with a few drops of distilled or deionized water before contact. Use a consistent procedure and suitable location; non-damaging conservation testing is not promised.

Limited-volume aqueous samples

The linked manual specifies at least 0.5 mL in a flat-bottom container with an inner diameter no greater than 19 mm. Keep that volume and vessel geometry together; neither number establishes the electrode diameter or an unrestricted droplet capability.

General liquid comparisons

Test compatible aqueous solutions with consistent contact and time to stabilize. For routine liquid immersion, the standard bulb configuration may be more convenient.

PH60F-Z illustrated sample contact
Illustrative flat-probe paper contact. Wet with distilled or DI water as instructed; this photo does not establish dry or non-damaging testing. Book and other sample props are not supplied.

Control the water contact.
Control the comparison.

Start with fresh buffers and the correct USA or NIST setting. Calibrate at the neutral standard first, then choose additional points appropriate to the expected sample. Rinse between standards, wait for the stability indicator and complete successive points without switching off. Used buffer portions should not return to stock bottles.

For paper, fabric or leather, wet the selected area with distilled or deionized water and establish gentle contact with the flat membrane. For small liquid samples, use at least 0.5 mL in a flat-bottom vessel of ≤19 mm inner diameter. Do not press the glass hard against the surface.

Allow sample temperature to stabilize. ATC covers 0-50°C and corrects electrode response, not all chemical pH changes with temperature. The -2.00 to 16.00 pH display range is not universal compatibility with strong acids, alkalis, solvents or extreme samples.

A closer look at the supplied sensor.

PH60F-DE replacement pH probe with flat glass membrane
PH60F-DE is the matching pH probe geometry. A replacement head is a separate maintenance purchase; the photo does not promise a particular shield revision.

Protect the flat face.
Restore clean wet contact.

Rinse away sample residue before and after use. Avoid wiping, rubbing or scraping the glass membrane. Use an appropriate cleaning procedure, then condition the probe in 3M KCl and recalibrate before relying on the next measurement.

Keep the protective cap moist and follow the supplied storage instructions, using Apera 3M KCl as directed for storage and conditioning. Do not soak the probe in purified water. Refresh contaminated cap solution rather than carrying residue into the next sample; this liquid is not an internal reference refill.

Replace with PH60F-DE, AI3715-E. Remove the cap, loosen the ring, align the connection without force and tighten. Condition and calibrate after replacement. Never pull off fixed parts or assume every illustrated shield is removable.

PH60F-Z probe cleaning and 3M KCl storage guide
Original care guide, not an exact bottle or probe rendering. Follow the supplied instructions; the KCl icon does not indicate bottle size or an internal reference refill.
PH60F-Z sample-contact method illustration
A practical method guide. This original illustration is schematic, not exact probe geometry; the measurement conditions also appear in the accompanying text.
PH60F-Z display and measurement, Bluetooth and calibration buttons
Display and physical controls detail. The shown reading is illustrative. HOLD freezes a reading; it is not a meter measurement-history logger.

Read the meter.
Know what is held.

Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.

Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.

Choose a connected workflow.
Keep its limits clear.

The tester measures and calibrates without a phone. Connect a compatible smartphone inside ZenTest, rather than treating operating-system PIN pairing as the measurement workflow. Bluetooth, required phone permissions and a nearby powered tester are needed for new connected readings. A smartphone is not included.

ZenTest offers Simple, Dial, Graph and Table views, with manual and timed recording, measurement/calibration records, and tools for notes, photos and location tagging. Available parameters still depend on the exact body and fitted head. Display choices cannot add pH or conductivity to an unsupported model.

Account and cloud functions depend on the compatible app, service and internet connection. Reviewing already saved records while disconnected is not continuous measurement acquisition outside Bluetooth range. Keep an independent copy of important records and check the current app listing for device compatibility before purchase.

Publisher documentation describes data sharing/export, and Apple release history identifies CSV. Native Excel or PDF reports, exact current logging intervals, and identical export behavior on both operating systems are not promised. Neither the meter nor this app overview establishes an immutable audit trail, regulatory compliance, guaranteed background alarms or offsite safety monitoring. Check your recordkeeping procedure before relying on connected data.

Official ZenTest pH dial display illustration
Official app illustration with an example pH reading. Your own compatible phone is required; screen appearance can vary. This is not a promise of live offsite monitoring.

Compare a standalone alternative.

Alternative format: Apera PH60F Flat-Surface pH Tester Kit (AI312). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.

PH60F-Z buyer questions

Can I measure a dry surface directly?

No. Wet paper, fabric and leather with distilled or deionized water as instructed. Keep water quantity, preparation and contact consistent when comparing samples. This is not a clinical diagnostic instrument.

Will a single droplet be enough?

Not as a general claim. The specified small-volume method requires at least 0.5 mL in a flat-bottom vessel with an inner diameter at most 19 mm. A random droplet on an open surface is not that method.

Is pH 10.01 buffer supplied?

The US-linked PH60F-Z manual lists pH 10.01 buffer as sold separately. Plan additional standards around your sample range; pH 4.00 and 7.00 buffers are listed with the kit. No buffer bottle volume is promised here.

Can I use the tester without ZenTest?

Yes. Measurement, calibration, stability indication and HOLD work on the tester. Logging belongs to the app; a held value is not meter history for later upload.

Which replacement probe fits PH60F-Z?

PH60F-DE (AI3715-E) is the matching replacement. PH60-DE, PH60F-DE and PH60S-DE are supported pH alternatives, sold separately. Choose by sample type and recalibrate after fitting.

Can I add ORP or conductivity?

Optional ORP60-DA, AI3717-DA, replaces the pH probe for ORP. Do not substitute ORP60-DE. A conductivity probe is not a supported EC upgrade.

What is included with the kit?

Tester with matching probe and cap, pH 4.00 and 7.00 buffers, calibration vials, 3M KCl, lanyard, case, instructions and four AAA batteries. Phones, sample props and alternate probes are not supplied.

What should I check before replacing a probe?

Check buffers, cleanliness, hydration and connection; recalibrate and verify a known buffer. Warranty excludes routine wear, accidental damage and incorrect storage.

Confirm the exact item before ordering.

Review PH60F-Z AI3715 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.

Back to price and ordering ↑
    SpecificationDetail
    Model / catalogPH60F-Z / AI3715
    Included pH probe / replacementPH60F-DE / AI3715-E
    Small-volume method≥0.5 mL; flat-bottom vessel inner diameter ≤19 mm
    Instrument pH display range-2.00 to 16.00 pH; not unrestricted sample compatibility
    pH resolution0.01 pH default; selectable 0.1 or 0.01 pH
    pH accuracy±0.01 pH ±1 digit
    pH calibrationAutomatic recognition; 1-3 points
    USA buffer choices1.68, 4.00, 7.00, 10.01, 12.45; neutral first
    NIST buffer choices1.68, 4.01, 6.86, 9.18, 12.45; neutral first
    Temperature / ATC0-50°C / 32-122°F
    Temperature accuracy±0.5°C
    Optional ORP-1000 to +1000 mV; ±0.2% F.S.; ORP60-DA required
    PowerFour AAA batteries
    EnclosureIP67; floats when correctly assembled
    RecordsApp-based logging; no meter measurement-history logger
    Limited manufacturer warranty24 months instrument / 6 months probe from delivery; exclusions apply
    Warranty2-year instrument / 6-month probe limited warranty; terms and exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3715
    Blue Tiger SKUBTS-AI3715
    Order unit1 exact ZenTest tester kit
    Order contentsPH60F-Z tester: With PH60F-DE pH probe and protective/soaking cap.; Calibration buffers: pH 4.00 and 7.00; bottle volumes not specified.; Calibration vials: For separate working portions of buffer.; 3M KCl storage solution: For probe storage and conditioning as instructed.; Four AAA batteries: Pull the battery insulation slip before first use.; Carrying case and lanyard: Keep the tester and routine supplies together.; Instructions: Setup, calibration, measurement and care guidance.

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PH60F-Z official documents

    Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat