Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH910 Benchtop pH Meter Kit | AI5610 Default Title Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Default Title Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments
Apera PH910 Benchtop pH Meter Kit | AI5610 Benchtop pH Meter Apera Instruments

Apera PH910 Benchtop pH Meter Kit | AI5610

$450.00

    A clear calibration sequence. A serviceable sensor. A recorded reading.

    • LabSen 211 plus separate MP500 temperature probe
    • One to three standard pH calibration points
    • 200 stored data sets with date and time
    • USB output with software-revision checks

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH910 / AI5610

A focused pH bench with a refillable glass electrode

PH910 combines guided pH calibration, a color display and 200-set data storage with the LabSen 211 pH electrode and separate MP500 temperature probe. It is a practical station for repeatable aqueous pH work where sensor care, temperature and calibration records matter as much as the displayed number.

Choose PH910 when the bench needs pH, mV and temperature rather than conductivity. Its dedicated pH input accepts a replaceable BNC electrode, while the separate temperature input keeps automatic compensation available with the supplied LabSen probe.

Apera PH910 meter with its actual model label and supplied sensors
Actual PH910 manufacturer photograph. Display values illustrate the interface, not a sample result; see the written kit list for all included items.
Which meter kit fits my measurement?Click or tap to compare all six measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Choose the electrode for the sample.

A genuinely separate temperature channel

LabSen 211 has no built-in temperature sensor. Connect its BNC plug to pH/mV and MP500 to the pH temperature RCA socket. Keep both sensing ends in the same sample for automatic compensation. A reference-electrode socket is also provided; it is not a second independent pH channel.

Read the state of the measurement

The screen identifies the active measurement, temperature, ATC or MTC status, electrode slope and completed calibration ranges. The smiling stability icon and optional HOLD state have different purposes: stability helps you decide when to record, while HOLD locks the displayed result.

Standard buffers or a defined custom method

Automatic calibration supports one to three points using USA, NIST or CH buffers. The manual treats user-defined calibration separately: one or two points, with values entered at the working temperature. Recognizing five USA buffer values does not mean five-point calibration.

A refillable reference, not a disposable gel-only body

LabSen 211 uses a hemispherical S-type glass membrane, ceramic junction and long-life reference assembly containing a silver reference wire and AgCl. Its reference electrolyte can be replenished. The construction illustration explains the assembly, not an unbreakability claim or a guaranteed response time.

Know what this configuration supplies.

Included item Order contents
PH910 meter, AI5610 One pH/mV/temperature benchtop instrument.
602 flexible electrode holder One adjustable holder for positioning the supplied sensors.
LabSen 211 pH electrode, AI3101 One refillable glass combination electrode with BNC connector. Temperature is measured separately.
MP500 temperature probe, AI1350 One stainless-steel temperature probe with RCA connector and 30 kΩ thermistor.
pH buffers pH 4.00, 7.00 and 10.01; one 50 mL bottle of each.
USB cable and software flash drive One of each. The current US kit list labels the drive PC-Link 9500; confirm the compatible software revision before deployment.
9 V adapter and user manual One of each. Computers, sample vessels and optional ORP electrodes are not included.
PH910 with 602 flexible electrode holder
Actual PH910 setup showing the adjustable 602 holder. Position sensing ends clear of the vessel bottom; the holder is not a magnetic stirrer.

Match the sample and preparation method.

General aqueous laboratory checks

Suitable for routine checks of compatible prepared solutions, water samples and rinses. A stationary holder helps keep immersion and handling consistent across a batch. Record sample identity separately alongside the meter record.

TRIS-buffer work

The supplied LabSen 211 is explicitly described as TRIS-compatible. Select an appropriate calibration and cleaning routine for the actual formulation; compatibility with TRIS does not establish suitability for every biological or pharmaceutical sample.

Know when to change the electrode

The manual calls for specialized sensors for viscous, low-ionic-strength, solid, strongly acidic or alkaline samples and demanding temperature conditions. A numerical meter range is not evidence that the supplied glass electrode is suitable for every material within that range.

Original pH calibration screen prompting immersion in pH 7 buffer
Original 910-family calibration prompt: immerse the rinsed pH electrode in pH 7.00 buffer, wait for the stability icon, then confirm. This screen illustrates standard calibration, not a guarantee that any buffer will be recognized.

Set up the probe, then build the calibration

Position the holder so neither sensing tip rests on the beaker bottom. Connect the power adapter and both sensor plugs. Loosen the storage-bottle cap before removing LabSen 211, rinse with purified water and open its blue refill-hole plug. Keep the electrical connectors dry and avoid pulling cables.

Use fresh buffer portions in clean vessels. For the normal three-point USA routine, begin with pH 7.00, then calibrate with pH 4.00 and 10.01. Rinse between buffers and wait for the stability indication before confirming. A newly connected LabSen 211 needs at least a two-point calibration.

Review the stored calibration and slope before measuring. A buffer-error or stability warning calls for checking buffer identity, contamination, immersion and electrode condition, not simply accepting the displayed value. For custom buffers, use the documented one- or two-point procedure and keep calibration and measurement temperatures the same.

Rinse into a waste vessel, immerse the electrode and MP500 in the sample, move gently to release trapped air, then wait for a settled reading. ATC compensates electrode response; it does not make a sample chemically temperature-independent. Save the value with temperature and the correct date and time.

Original 910 calibration-information screen example
Original 910-family calibration-record screen. Review the recognized buffer points and electrode slope after calibration. The historical values shown are interface examples, not calibration data for the instrument you receive.

Understand the sensing end and connections.

LabSen 211 refillable glass pH electrode
LabSen 211, AI3101, has no built-in temperature sensor. Its separate MP500 companion supplies temperature for pH compensation. Glass remains breakable.
MP500 stainless-steel temperature probe with RCA connector
MP500, AI1350: separate 30 kΩ temperature probe. Its -10 to 110°C probe rating does not extend the PH910 meter beyond 0 to 100°C.
Manufacturer diagram of LabSen 211 reference assembly with silver chloride marked AgCl
Original LabSen reference-construction illustration: AgCl means silver chloride. The manufacturer calls this a long-life system; the stability and service-life wording describes design intent, not a guaranteed electrode lifespan or performance improvement in every sample.

Maintain the reference solution and protect the glass

After testing, rinse the sensing end and return it to its bottle containing 3M KCl solution, AI1107. Close the refill-hole plug for storage. Do not store LabSen 211 in distilled or deionized water. Those waters are useful for rinsing, not for storing this pH electrode.

When reference solution falls to half the electrode height, replenish it with 3M KCl through the refill opening. Replace contaminated storage solution. For stubborn deposits, the exact probe manual describes Apera cleaning solution AI1166, followed by reconditioning in KCl and recalibration. Select cleaning chemistry for the contaminant; never assume aggressive solvents are harmless.

Keep the adapter and meter away from spills. Power down before removing the USB cable or power connection, as instructed in the 910 USB manual. Treat glass as breakable even though the manufacturer promotes a firm membrane. Cleaning and correct storage cannot prevent eventual electrode aging.

Original LabSen manual drawing showing how to loosen the storage-bottle cap
Original LabSen care drawing: loosen the bottle cap before withdrawing the electrode. Store LabSen 211 in 3M KCl, AI1107, with its refill plug closed. Do not pull against a tightened cap or store this pH electrode in pure water.
Manufacturer PH910 rear photograph showing sensor sockets, reference socket and 9 V power
Manufacturer PH910 rear photograph: pH/mV BNC, pH temperature RCA, reference socket and 9 V power. Blank conductivity positions do not provide a conductivity channel. This photograph does not document USB placement; USB is documented separately in the current specification and exact USB manual.
Original 910 manual pH screen with numbered status callouts
Original 910-family pH screen example. Accessible legend: mode, pH, temperature, slope, completed calibration ranges, stored-record count, ATC/MTC, HOLD, stability, date/time and timed logging. The monitor symbol indicates a computer connection. Values shown are examples.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

200 records, with an explicit software check

The current US specification is 200 data sets, with numbering, date, time, measurement and temperature. Manual saving and timed logging are available. Download and verify records before clearing full memory. The older PH910 USB manual has an inconsistent 100-group specification table, but its logging section describes 200; the current US 200-set specification governs this listing.

The exact 910 USB manual describes PC-Link 910, memory download, time synchronization and export to an Excel document. It also warns that readings sent directly to the computer are not simultaneously saved in instrument memory. Verify the intended logging destination before a long run.

The current product page links a browser tool titled Web PC-Link 9500 Series, and lists a PC-Link 9500 flash drive. Neither label establishes PH910 protocol compatibility. Confirm exact-model and firmware support before relying on browser, Mac, CSV or JSON workflows. Recordkeeping features alone do not guarantee GLP compliance.

Original PH910 manual pH screen with saved-record count
Original PH910 manual pH memory-status example: the document icon and count at the lower right indicate saved readings. Current US capacity is 200 sets. Verify the download before clearing memory; display values are illustrative.
Original PC-Link 910 desktop software interface from the exact instrument manual
Historical PC-Link 910 interface from the exact USB manual. Legend: 1 meter serial number; 2 data area; 3 operation buttons; 4 computer connection; 5 meter memory. This is not evidence of compatibility with the newer 9500 browser tool; computer not included.

Compare another benchtop format.

Alternative format: Apera PH950 Benchtop pH Meter Kit with LabSen 211 and 606 TestBench. The linked meter has a different bench arrangement, supplied probes or record workflow. Review its own kit and instructions before choosing. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

PH910 buyer questions

Which pH electrode is in the current PH910 kit?

The current US AI5610 kit list names LabSen 211, AI3101, and MP500, AI1350. The 201T-F, AI1302, appears as an accessory and in an older regional kit manual, not in the current US kit list. Verify the carton configuration if replacing an older unit.

Does the 201T-F range conflict apply here?

Not to the current LabSen 211 kit. If you separately fit 201T-F, its current page specifies 0 to 13 pH and 0 to 60°C, versus 0 to 14 pH and 0 to 80°C in its manual. Use the narrower limits until the supplied revision is confirmed; prolonged testing above 50°C is cautioned against.

What temperature limits should I use?

The meter measures and compensates pH from 0 to 100°C. LabSen 211’s current page states 0 to 100°C; its manual states -5 to 100°C. MP500 alone is rated -10 to 110°C. Use the shared 0 to 100°C envelope, with a specialized electrode assessment for demanding hot or cold samples.

Can PH910 measure conductivity or ORP?

It cannot measure conductivity. Its ±2000 mV mode can be used for ORP with an appropriate separately purchased ORP electrode. The supplied LabSen 211 is a pH electrode, not an ORP probe.

How many pH calibration points are supported?

One to three with recognized standard buffers; one or two with user-defined buffers under the exact USB manual. Custom values require temperature-matched calibration and measurement, rather than automatic recognition of arbitrary solutions.

Can it connect to the new browser software?

USB output is documented, but exact PH910 support was not established in the linked 9500 browser utility. Confirm compatibility before specifying that workflow. A flash-drive name is not a protocol specification.

Are a stirrer, printer or TestBench 606 included?

No. The current kit list includes the 602 holder, probes, buffers, cable, flash drive, adapter and manual. It does not establish a stirrer, printer or TestBench 606 as included or supported.

What warranty applies to this US kit?

The current US product page specifies a limited warranty of three years for the instrument and six months for the probe, from delivery, for covered defects attributable to Apera. Accidental damage, misuse, wear, transportation or storage damage, failure to follow instructions and unauthorized repair or modification are excluded.

Confirm the exact configuration before ordering.

Review PH910 AI5610 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / SKUPH910 / AI5610
    Measured parameterspH, mV, temperature
    Meter pH range / resolution0.00 to 14.00 pH / 0.1 or 0.01 pH
    Instrument pH accuracy±0.01 pH ±1 digit
    pH calibration1 to 3 standard points; 1 to 2 custom points
    pH compensation0 to 100°C, automatic or manual
    Current supplied pH electrodeLabSen 211, AI3101; 0 to 14 pH; use current-page 0 to 100°C limits
    Temperature probeMP500, AI1350; RCA, 30 kΩ; probe-only -10 to 110°C
    mV range / resolution / accuracy±2000 mV / 1 mV / ±0.1% F.S. ±1 digit
    Temperature range / resolution / accuracy0 to 100°C / 0.1°C / ±0.5°C (current US page)
    Storage / output200 sets / USB; exact software revision requires confirmation
    Power supplyDC 9 V / 600 mA
    Instrument dimensions / net weight195 × 215 × 100 mm / 0.9 kg; not shipping weight
    Limited warrantyInstrument: 3 years; probe: 6 months from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI5610
    Blue Tiger SKUBTS-AI5610
    Order unit1 exact listed meter-kit configuration
    Order contentsPH910 meter, AI5610: One pH/mV/temperature benchtop instrument.; 602 flexible electrode holder: One adjustable holder for positioning the supplied sensors.; LabSen 211 pH electrode, AI3101: One refillable glass combination electrode with BNC connector. Temperature is measured separately.; MP500 temperature probe, AI1350: One stainless-steel temperature probe with RCA connector and 30 kΩ thermistor.; pH buffers: pH 4.00, 7.00 and 10.01; one 50 mL bottle of each.; USB cable and software flash drive: One of each. The current US kit list labels the drive PC-Link 9500; confirm the compatible software revision before deployment.; 9 V adapter and user manual: One of each. Computers, sample vessels and optional ORP electrodes are not included.

    Apera Manufacturer Limited Warranty

    The current US product page specifies a limited warranty of three years for the instrument and six months for the probe, from delivery, for covered defects attributable to Apera. Accidental damage, misuse, wear, transportation or storage damage, failure to follow instructions and unauthorized repair or modification are excluded.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

    PH910 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.