Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Default Title Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Default Title Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments
Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode Benchtop Conductivity Meter Apera Instruments

Apera EC700 Benchtop Conductivity Meter Kit with 2301T-F Electrode

$339.00

    Straightforward EC/TDS measurements with 50-record recall, max/min mode and a compact detachable holder.

    • 2301T-F conductivity/temperature electrode with BNC/RCA plugs
    • 0 to 200 mS/cm conductivity range; four auto ranges
    • One to four recognized calibration standards
    • 50 stored sets and max/min mode; no documented USB export

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / EC700 / AI502

A focused conductivity bench.
Read, store and recall without a computer.

EC700 provides conductivity, calculated TDS and temperature measurement with a replaceable 2301T-F electrode. Its backlit display keeps the result, temperature and calibration indicators visible, while 50-set internal memory supports short bench sessions. Three conductivity standards and a detachable holder make this a practical starting point for routine aqueous measurements.

Choose AI502 for direct controls, recognized-standard calibration and on-meter records rather than computer export. EC700 is a dedicated conductivity instrument, not PH700 and not a pH combination kit. Its K=1 plastic-body electrode and adjustable temperature settings suit regular-range work when the sample and method are compatible.

EC700 conductivity meter with 2301T-F probe and detachable holder
Exact EC700 bench configuration with its conductivity probe and one detachable holder. Manufacturer display values are illustrative.
Which meter kit fits my measurement?Click or tap to compare all six measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Choose the electrode for the sample.

Read the result and its context

The large LCD shows conductivity or TDS together with temperature. A smile symbol indicates a settled reading; L, M and H icons track the recognized calibration ranges. These are useful operator prompts, not automatic acceptance criteria for a sample. The original screen illustration is a manufacturer example, not a certificate or a result measured for this listing.

One electrode handles conductivity and temperature

The 2301T-F combines a platinum-black conductivity cell with a 30 kΩ thermistor in a POM body. BNC carries conductivity and RCA carries temperature. Current exact-probe documentation identifies POM, superseding the older EC700 manual's generic plastic description. The detachable holder can mount on either side of the meter to suit the available workspace.

Useful settings without a software workflow

Select K=0.1, 1 or 10, adjust reference temperature from 15 to 30°C, and set the compensation coefficient from 0.00 to 9.99%/°C. Defaults are K=1, 25°C and 2.00%/°C. The TDS factor adjusts from 0.40 to 1.00, default 0.71. Record these choices when comparing batches; a different conversion factor can change TDS without changing the sample.

Know what this configuration supplies.

Included item Order contents
EC700 benchtop meter AI502 conductivity/TDS/temperature configuration.
2301T-F electrode K=1 POM conductivity/temperature probe with BNC/RCA connections and storage cap.
Three conductivity standards 84 µS/cm, 1413 µS/cm and 12.88 mS/cm; one 50 mL bottle each.
Detachable electrode holder Stand, supporting pole and clip; installs on either side of the meter. One holder is supplied.
Power adapter 9 V bench supply; current US specification lists 120 V AC, 60 Hz input and 300 mA DC output.
User manual and quick-start guide Operating references listed with the current US kit. No USB cable or software media are listed.
EC700 holder installed beside meter with alternate side-mount inset
Original holder feature graphic shows alternate left/right mounting positions. The kit includes one holder, not two.

Match the sample and preparation method.

General water-solution testing

Use EC700 for routine conductivity checks on compatible aqueous samples, preparation comparisons and rinse-water trends. Keep vessel cleanliness, immersion and temperature consistent. Conductivity is an aggregate response to ions, not identification of a particular dissolved substance or proof that water is safe to drink.

Education and practical training

Dedicated CAL, ENTER and memory controls make calibration, stabilization and recall visible steps. Students can compare conductivity with calculated TDS while learning why conversion factors matter. The instrument does not independently weigh dissolved solids, and neither pH nor salinity measurement is documented for this exact EC700 configuration.

Small batches with a written record

Fifty stored sets suit work where the operator reviews readings on the meter and transfers the required information to a worksheet. Max/min mode highlights the extremes recorded during a measurement session. It is not an unattended computer logger, and a maximum or minimum value alone does not preserve the sample identities or full sequence needed for an investigation.

EC700 calibration sequence from recognize to stable confirm to completed reading
Original EC700 calibration sequence, top to bottom: enter CAL and recognize 1413 µS/cm; wait for the stable icon and press ENTER; return to measurement with the M calibration icon. These are instructional examples.

Use fresh standards.
Confirm stability before accepting calibration.

Install the holder, connect the correctly rated adapter, and insert the electrode's BNC and RCA plugs into COND and TEMP. Remove the protective storage cap and confirm K=1 for the supplied cell. Rinse the electrode with distilled or deionized water, remove excess water gently, then rinse with a little standard when practical. Immerse and stir briefly to release bubbles.

EC700 recognizes 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm for one- to four-point calibration. Press CAL, wait for the recognized value and stable symbol, then confirm with ENTER. The kit provides the first three standards in 50 mL bottles. The fourth is not included. Use clean portions and progress from low to high conductivity to reduce carryover.

The exact EC700 manual recommends at least two calibration points after a new electrode or factory reset; the exact probe guide recommends two or three. For routine work, verify a suitable standard and adjust calibration frequency to your accuracy needs and sample conditions. User-defined standard calibration is not documented for EC700. Do not import the custom-calibration instructions of a different model.

Understand the sensing end and connections.

Original 2301T platinum-black cell and sensing surface graphic
Original 2301T cell graphic supplied on the EC700 page. The rated 200 mS/cm probe range is not an independent performance test. Fast, Accurate and Stable are manufacturer design descriptions; method conditions still matter.

Clean water in the cap.
Gentle handling at the sensing tip.

Rinse the conductivity electrode before and after each sample and calibration. Gently blot away excess rinse water without rubbing the platinum-black surface. For the next sample, a small sample rinse can limit dilution. Brief stirring after immersion releases trapped bubbles; avoid contact between the sensing head and the vessel bottom.

Follow the exact 2301T-F guide for storage: keep the cap filled with clean distilled or deionized water and replace it when contaminated. The older meter manual includes generic dry-storage language, but the supplied probe's own instructions specifically require a water-filled cap. This is not a pH electrode and its cap should not be filled with KCl storage solution.

For organic residue, the probe guide describes warm detergent water and alcohol cleaning with a soft brush; mineral deposits require the guide's specified cleaning treatment. Do not polish or scrape the sensing surface. Rinse and recalibrate after cleaning. Keep connectors dry and clean. IP54 protects the meter against dust and splashes, not immersion or unrestricted chemical exposure.

Supplied 2301T-F conductivity electrode portrait
2301T-F probe body and sensing end. Follow its exact instructions: store in a cap with clean distilled or deionized water, not pH-electrode KCl solution. Cap is not shown in this photograph.
Original EC700 screen detail with stable and calibration callouts
Original EC700 LCD detail. Callout 1 identifies the stable-reading smile symbol; callout 2 identifies L/M/H calibration icons. The actual display is conductivity and temperature, not pH. Example values are illustrative.
Original EC700 numbered LCD diagram
Original EC700 legend: 1 mode; 2 value; 3 calibration status; 4 measurement unit; 5 temperature unit; 6 calibration unit; 7 calibration/record number; 8 M+/RM; 9 temperature; 10 error; 11 ATC/MTC; 12 completed calibration; 13 stable; 14 max/min. All-segment display is a diagram, not a sample result.
EC700 rear connector diagram for COND TEMP and DC9V
Original EC700 connector drawing: COND is BNC, TEMP is RCA and DC9V is the power input. Blank enclosure positions are not additional active measurement channels; no USB output is shown.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Store 50 sets.
Recall them locally, then preserve your worksheet.

A short press of the memory key saves the stable measurement and shows M+ with its storage number. A long press recalls the last saved result and shows RM; arrow keys browse saved records. Documented record content includes numbering, measurement, unit, temperature and temperature-compensation status. Date/time stamps are not listed for EC700.

When memory reaches 50 groups, the FUL indication tells you to clear storage before saving more. Copy needed records into your own worksheet first. The parameter table identifies P6 as clear stored data and P7 as factory reset; older narrative cross-references in the manual are inconsistent. Confirm the menu label rather than clearing data by a quoted parameter number alone.

No USB connector, software package or computer export workflow is documented in the exact EC700 manual or current US kit list. Plan for on-meter review and manual transcription. Do not transfer EC910 or EC800 software claims to this model. Neither internal memory nor the max/min function establishes a regulatory audit trail or a validated electronic laboratory record.

EC700 display with M+ and storage number one
Original EC700 storage example. A short memory-key press stores a reading and shows M+ plus its number. The example value is not a result tested for this reference.
EC700 display with RM and recalled record 28
Original EC700 recall example. RM 28 identifies the recalled record, not a time stamp. Review the reading, unit, temperature and compensation status before transcribing it.

Compare another benchtop format.

Alternative format: Apera EC800 Laboratory Benchtop Conductivity Meter Kit with 2301T-F Electrode. The linked meter has a different bench arrangement, supplied probes or record workflow. Review its own kit and instructions before choosing. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

EC700 buyer questions

Does EC700 measure pH or salinity?

No. The exact manual documents conductivity, TDS and temperature. PH700 is a different instrument. A pH wording error in one manufacturer screen graphic does not create pH capability, and salinity is not an EC700 mode.

What is included for calibration?

One 50 mL bottle each of 84 µS/cm, 1413 µS/cm and 12.88 mS/cm. The meter also recognizes 111.8 mS/cm, but that standard is a separate purchase. No pH buffers are listed.

Is the conductivity probe glass?

No. The supplied 2301T-F is a POM plastic-body K=1 electrode with a platinum-black cell and built-in 30 kΩ temperature sensor. Its BNC and RCA plugs both need the correct connections for automatic temperature compensation.

Can it calibrate to my own standard value?

The exact EC700 sources document automatic recognition of four standard values, not user-defined calibration. Choose a model with explicitly documented custom calibration if your procedure requires a nonstandard value.

Does 200 mS/cm mean the supplied cell is best at every point?

No. The probe is rated to 200 mS/cm, but a meter limit is not a method guarantee. Consider cell constant, sample composition, polarization, contamination and calibration. Changing the probe cannot extend EC700 beyond its 200 mS/cm electronics range.

What temperature limits should I use?

The meter displays 0 to 100°C, while conductivity compensation is specified from 0 to 50°C. The probe manual separately lists a 0 to 80°C operating temperature. These are different limits, not interchangeable permissions.

Can I export the stored results?

No export facility is documented for EC700. Use its 50-set recall to review readings and transfer required information manually. If automated transfer is a purchasing requirement, select a meter with an explicitly supported computer interface.

What warranty applies?

Both the current US EC700 page and exact EC700 manual specify two years for the instrument and six months for the probe from delivery. This limited warranty covers qualifying defects, not misuse, improper maintenance, unauthorized repair or other stated exclusions.

Confirm the exact configuration before ordering.

Review EC700 AI502 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / SKUEC700 / AI502
    Measurement modesConductivity, calculated TDS, temperature
    Supplied electrode2301T-F; K=1.0; POM; BNC/RCA; 30 kΩ
    Conductivity range0 to 200 mS/cm; four automatic ranges
    Conductivity resolution0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm
    Conductivity accuracy±1.0% FS ±1 digit per exact manual
    TDS range0 to 100 g/L
    Calibration1 to 4 points: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
    Custom standard modeNot documented for EC700
    Cell constants0.1 / 1 / 10 cm⁻¹
    Conductivity temperature compensation0 to 50°C; automatic or manual
    Reference temperature / coefficient15 to 30°C / 0.00 to 9.99%/°C
    TDS conversion factor0.40 to 1.00; default 0.71
    Meter temperature0 to 100°C; 0.1°C resolution; ±0.5°C ±1 digit per manual
    Memory / record content50 sets; numbering, measurement, unit, temperature and compensation status
    Computer exportNo documented USB or export workflow
    Protection / powerIP54 / DC 9 V, 300 mA
    Probe dimensions / cable12 mm diameter × 155 mm / 3 ft
    Limited warranty2 years instrument; 6 months probe; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI502
    Blue Tiger SKUBTS-AI502
    Order unit1 exact listed meter-kit configuration
    Order contentsEC700 benchtop meter: AI502 conductivity/TDS/temperature configuration.; 2301T-F electrode: K=1 POM conductivity/temperature probe with BNC/RCA connections and storage cap.; Three conductivity standards: 84 µS/cm, 1413 µS/cm and 12.88 mS/cm; one 50 mL bottle each.; Detachable electrode holder: Stand, supporting pole and clip; installs on either side of the meter. One holder is supplied.; Power adapter: 9 V bench supply; current US specification lists 120 V AC, 60 Hz input and 300 mA DC output.; User manual and quick-start guide: Operating references listed with the current US kit. No USB cable or software media are listed.

    Apera Manufacturer Limited Warranty

    Both the current US EC700 page and exact EC700 manual specify two years for the instrument and six months for the probe from delivery. This limited warranty covers qualifying defects, not misuse, improper maintenance, unauthorized repair or other stated exclusions.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

    EC700 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat