Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Default Title Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Default Title Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments
Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480 Portable Optical Dissolved Oxygen Meter Apera Instruments

Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480

$1,150.00

    An optical probe, a humid-air calibration sleeve and clear on-screen readings.

    • DO803 optical DO/temperature probe with 10-ft nominal cable
    • 0 to 20.00 mg/L and 0 to 200.0% saturation
    • Automatic temperature and pressure compensation; manual salinity
    • Stable-reading indicator and optional HOLD; no onboard logging

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / DO850 / AI480

Optical dissolved oxygen, with a straightforward field-reading workflow

DO850 combines a portable meter with the DO803 luminescent optical probe and a nominal 10-ft cable. It measures dissolved oxygen concentration, percent saturation and temperature without consuming oxygen at the sensor. This AI480 kit suits spot checks where an operator records the result, rather than needing an onboard data logger.

Choose DO850 for general-water DO measurements with automatic temperature and barometric compensation, manual salinity entry and optional reading hold. It is not a pH or conductivity meter, and HOLD does not create a stored record.

DO850 optical DO meter with nominal 10-ft cable and supplied probe
AI480: DO850 with DO803 optical DO/temperature probe. Exact 10-ft kit page photograph; cable length is established by SKU and manual, not inferred from the coiled cable.
Which meter kit fits my measurement?Click or tap to compare all six measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Choose the electrode for the sample.

An optical signal instead of oxygen consumption

A blue LED excites the sensing layer and a photodiode reads its red luminescence. Oxygen changes that optical response. This avoids the oxygen-consuming reaction of galvanic or polarographic probes and removes their continuous-flow requirement. It does not eliminate bubbles, fouling, temperature equilibration or the need to check calibration.

Two automatic corrections, one operator input

The probe supplies temperature for automatic compensation over 0 to 50°C. The meter also compensates barometric pressure over 60 to 120 kPa. Salinity is entered manually from 0 to 45 ppt, so determine the sample salinity independently before relying on mg/L or ppm in brackish or marine water.

A display that distinguishes stability from retention

DO and temperature appear together on the backlit LCD. Wait for the stability symbol to remain visible. Optional auto-lock holds a reading after more than ten seconds of stability. This helps with reading the screen in the field, but is not memory storage or a USB export function.

A replaceable cap, not a disposable probe

The DO803 has a built-in temperature sensor and eight-pin connector. Its DO8032 luminescent cap and DO8031 storage/calibration sleeve are distinct service parts. There is no electrolyte refill or conventional membrane replacement, but cleaning, humid storage, calibration and eventual cap replacement remain necessary.

Know what this configuration supplies.

Included item Order contents
DO850 portable meter One instrument, exact US kit SKU AI480.
DO803 optical DO probe One probe with temperature sensor, fitted sensing cap and nominal 10-ft cable.
DO8031 calibration/storage sleeve One sleeve for a humid-air calibration and storage environment.
Spare storage sponges Four replacements; keep clean and damp.
Batteries and screwdriver Three AA batteries and one small screwdriver, listed on the current exact kit page.
Carrying case and instructions One case and one user manual. Replacement-cap programming equipment is not listed as part of this meter kit.
DO850 kit in an open carrying case
Manufacturer photograph from the exact 10-ft kit page. Use the itemized kit list for included components, rather than counting hidden pieces in the case.
DO850 with DO803 probe in its calibration and storage sleeve
Exact DO850 10-ft gallery photograph showing the sleeve fitted for storage or humid-air calibration. Remove it before immersing the sensor to measure.

Match the sample and preparation method.

Aquaculture and aquarium rounds

Compare DO at defined locations and times without continuously stirring the sample to feed an electrochemical reaction. Record water temperature and salinity assumptions alongside the result. A surface reading alone does not establish oxygen conditions throughout a tank or pond.

Water treatment and environmental spot checks

The carrying case and cable support portable sampling of compatible general water. Keep a consistent immersion depth, avoid entrained bubbles, and wait for thermal stability. The kit is not an unattended installation or proof of compliance with a particular analytical method.

Hydroponic and general-water process checks

Use the probe within its 0 to 50°C operating range. The current DO803 specification excludes strong acidic or alkaline water and organic solutions. Select a separately validated method for chemically aggressive samples rather than assuming optical sensing makes every liquid suitable.

Original optical DO principle diagram showing blue excitation and red luminescence
Original manufacturer principle illustration: the blue LED excites the sensing layer and the photodiode detects red luminescence. This explains the design, not a test result or an exact immersion-depth drawing.

Calibrate in humid air, then measure below the immersion line

Align and secure the eight-pin probe connector, inspect the cap and check the storage sponge. The manual asks for approximately 30 seconds after power-on before operations. No electrochemical polarization warm-up is needed, but this is not an instant-reading guarantee. Select concentration units and enter the correct salinity before sampling.

For saturated-air calibration, dampen the sleeve sponge, attach the sleeve and tighten its locking cap. Keep water droplets off the sensing surface. Allow five to ten minutes for the sleeve atmosphere and temperature to stabilize, then enter calibration and confirm only when the stability symbol remains on. For best accuracy the manual recommends this check before each day of use, despite reduced-calibration marketing language.

Zero calibration is not normally required on first use because it is performed at the factory. Perform it after replacing a probe or cap, after prolonged non-use, or when low-range accuracy at 0 to 2.0 ppm is important. The manual specifies fresh oxygen-free solution made from 2 g anhydrous sodium sulfite in 100 mL distilled or deionized water, effective for one hour; follow its handling and calibration steps.

Remove the sleeve for measurement. Immerse above the probe line, move briefly to release bubbles, then hold still until stable. The 30-second specification describes 90% response at 25°C, not the complete field cycle. The manual describes roughly one minute when temperatures are similar and about three minutes when probe and sample temperatures differ substantially.

Original numbered DO803 sensor and calibration sleeve assembly diagram
Original manual diagram. Legend: 1 sleeve bottom cover; 2 water-storage sponge; 3 sensor cap; 4 calibration/storage sleeve; 5 locking cap; 6 optical probe; 7 O-ring. For saturated-air calibration keep the sponge damp, not dripping, and keep droplets off the sensing face.
Original DO803 immersion-line drawing
Original manual depth guide: during sampling the water must be above the marked immersion line. Remove the storage sleeve for measurement. This is not the humid-air calibration arrangement.

Understand the sensing end and connections.

DO803 optical probe sensing end with stainless-steel cap
DO803 sensing end, shown without its storage sleeve. Protect the optical coating from scratching; do not exceed 50°C.

Keep the cap humid, clean and protected

The optical cap needs humid storage, not pH-electrode KCl solution. Keep the DO8031 sleeve sponge damp with clean water, not dripping, and close the locking cap. The sensing cap should sit in humid air rather than a pool of water inside the sleeve. Replace a dirty or moldy sponge. For storage beyond 30 days, the manual permits clean-water storage or checking the sleeved sponge every 30 days.

If the sponge has dried or the probe has spent over eight hours in dry air, rehydrate before measuring. The detailed maintenance instructions specify 24 hours in clean water at room temperature, or 48 to 72 hours in cold water. During measurement, remove the sleeve and immerse above the marked immersion line. Do not confuse that sampling depth with the humid-air calibration arrangement.

Protect the cap coating from scratches and temperatures above 50°C. Clean gently with a soft clean cloth; do not use alcohol or organic solvents. The manual describes 3% hydrogen peroxide for 15 to 30 minutes when disinfection is needed, followed by a clean-water rinse. Do not routinely remove or swap sensor caps; keep the interior dry and uncontaminated.

DO8032 is the replacement luminescent cap. Its advertised 8,000-hour service figure is a design estimate, not a guaranteed interval or warranty duration. Replacement requires the correct cap calibration coefficients. The current replacement page describes a probe-connected data box and installation-program flash drive, while the meter manual refers to cap-specific calibration codes. Follow the supplied replacement instructions; neither source establishes a QR-code or RFID procedure.

DO8031 storage and calibration sleeve with sponge at its base
The DO8031 sleeve creates humid air around the sensing cap. Dampen the sponge with clean water; do not fill the sleeve so the sensing cap sits in water. Inspect and replace dirty or moldy sponges.
Original DO803 exploded photo with luminescent cap removed
Original DO8032 service illustration, not normal storage: remove the cap only for appropriate service, keep the interior dry and follow the replacement instructions. No conventional membrane or electrolyte refill is needed.
DO803 replacement-cap data box connected between probe and a computer
Replacement-cap programming illustration from the DO8032 accessory page. It shows a data box connected to the probe and a computer; it is not ordinary meter data export. Computer and cap-service equipment are not listed as included in the meter kit. Confirm the supplied cap procedure and host requirements.
Original DO850 LCD diagram with numbered status icons
Original manual legend: 1 measurement mode; 2 reading; 3 symbol field; 4 measurement units; 5 temperature unit; 6 temperature value; 7 HOLD; 8 ATC/MTC; 9 reading stability; 10 low battery. All-segment illustration, not an actual sample result.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Use HOLD for reading, not for a saved dataset

DO850 is the simpler display-and-record choice. Its documented controls provide stable-reading indication and optional HOLD, but no 500-record memory or USB data workflow. Write down the result, units, temperature, sampling location and relevant calibration information in your own field record.

Choose DO8500 instead if timestamped onboard storage, timed recording or the documented USB PC-Link workflow is necessary. Those are different-model functions; the shared optical probe does not add them to DO850.

Original DO850 screen showing HOLD on a stable reading
Original DO850 manual screen: HOLD is a reading lock after more than ten seconds of stability. It is not a saved record, data logger or USB output. Record the result separately.

Complement your water-quality workflow.

Related workflow: Apera TN420 Portable White-Light Turbidity Meter. Turbidity and dissolved oxygen describe different water-quality properties; this link is a separate workflow, not a compatible accessory or interchangeable measurement. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

DO850 buyer questions

Which SKU and cable are supplied?

This is AI480, the nominal 10-ft DO850 kit. The manual calls the DO803 cable 3 m. It is not AI48033 and does not include the 33-ft DO810 cable configuration.

What ranges does it measure?

DO850 measures 0 to 20.00 mg/L or ppm, 0 to 200.0% saturation and 0 to 50°C. These are DO and temperature functions, not pH or conductivity ranges.

Does it adjust for seawater automatically?

No. Temperature and pressure are automatic, but salinity must be determined separately and entered manually from 0 to 45 ppt.

Is HOLD the same as a data logger?

No. HOLD locks a stable screen reading. DO850 does not have the DO8500 model’s 500-record storage and USB output.

Does optical mean calibration-free?

No. Use saturated-air calibration and follow the manual’s daily recommendation for optimal accuracy. Zero calibration has specific replacement, storage and low-DO use cases.

Is the probe maintenance-free?

No. There is no electrolyte to refill, but the cap must remain humid in storage, clean and undamaged. Replace a deteriorated cap using its matching calibration-coefficient procedure.

Can it read immediately in hot or stagnant water?

No instant-reading promise applies. Optical measurement does not need continuous flow, but bubbles and temperature differences still matter. Never exceed the probe’s 50°C limit.

What warranty applies?

The current exact kit page states three years for the instrument, two years for the DO803 probe excluding its cap, and one year for the DO8032 cap, from purchase. Coverage concerns material or manufacturing defects; improper use, normal wear, accidental damage, storage, transportation and unauthorized repair are excluded. The service-hour estimate is not a warranty.

Confirm the exact configuration before ordering.

Review DO850 AI480 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / kit SKUDO850 / AI480
    MeasurementLuminescent optical dissolved oxygen and temperature
    DO concentration range0 to 20.00 mg/L (ppm)
    Saturation range0 to 200.0%
    Selectable resolution0.01 or 0.1 mg/L (ppm); 0.1 or 1%
    DO concentration accuracy±2% of reading or ±0.2 mg/L, whichever is greater
    Saturation accuracy±2% of reading or ±2% saturation, whichever is greater
    Response specification90% response within 30 seconds at 25°C; full stabilization takes longer
    CalibrationSaturated-air point and zero-oxygen point
    Temperature range / resolution / accuracy0 to 50°C / 0.1°C / ±0.5°C
    Temperature compensationAutomatic, 0 to 50°C
    Barometric compensationAutomatic, 60 to 120 kPa
    Power / ingress ratingThree AA batteries / IP57
    Probe / cableDO803 with built-in temperature sensor; 10-ft nominal cable (manual: 3 m)
    Salinity compensationManual entry, 0 to 45 ppt
    Data handlingStable-reading display and optional HOLD; no onboard logger or USB output
    Limited warrantyInstrument 3 years; DO803 excluding cap 2 years; DO8032 cap 1 year; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI480
    Blue Tiger SKUBTS-AI480
    Order unit1 exact listed meter-kit configuration
    Order contentsDO850 portable meter: One instrument, exact US kit SKU AI480.; DO803 optical DO probe: One probe with temperature sensor, fitted sensing cap and nominal 10-ft cable.; DO8031 calibration/storage sleeve: One sleeve for a humid-air calibration and storage environment.; Spare storage sponges: Four replacements; keep clean and damp.; Batteries and screwdriver: Three AA batteries and one small screwdriver, listed on the current exact kit page.; Carrying case and instructions: One case and one user manual. Replacement-cap programming equipment is not listed as part of this meter kit.

    Apera Manufacturer Limited Warranty

    The current exact kit page states three years for the instrument, two years for the DO803 probe excluding its cap, and one year for the DO8032 cap, from purchase. Coverage concerns material or manufacturing defects; improper use, normal wear, accidental damage, storage, transportation and unauthorized repair are excluded. The service-hour estimate is not a warranty.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

    DO850 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.