DO850 combines a portable meter with the DO803 luminescent optical probe and a nominal 10-ft cable. It measures dissolved oxygen concentration, percent saturation and temperature without consuming oxygen at the sensor. This AI480 kit suits spot checks where an operator records the result, rather than needing an onboard data logger.
Choose DO850 for general-water DO measurements with automatic temperature and barometric compensation, manual salinity entry and optional reading hold. It is not a pH or conductivity meter, and HOLD does not create a stored record.
Each card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.
AI5610
Benchtop pH with records
LabSen 211 pH-only electrode and separate MP500 temperature probe.
AI5612
Benchtop conductivity with records
2301T-F cell and model-specific USB record workflow.
AI5614
Benchtop pH and conductivity
Separate pH and EC probes, each with its own temperature input.
AI502
Straightforward conductivity bench
2301T-F cell and local 50-set recall, without documented USB export.
AI480
Direct optical dissolved oxygen
10-ft DO803 optical probe; stable display and external recordkeeping.
AI485
Optical DO with recording
10-ft optical probe plus salinity electrode and documented logging.
A blue LED excites the sensing layer and a photodiode reads its red luminescence. Oxygen changes that optical response. This avoids the oxygen-consuming reaction of galvanic or polarographic probes and removes their continuous-flow requirement. It does not eliminate bubbles, fouling, temperature equilibration or the need to check calibration.
The probe supplies temperature for automatic compensation over 0 to 50°C. The meter also compensates barometric pressure over 60 to 120 kPa. Salinity is entered manually from 0 to 45 ppt, so determine the sample salinity independently before relying on mg/L or ppm in brackish or marine water.
DO and temperature appear together on the backlit LCD. Wait for the stability symbol to remain visible. Optional auto-lock holds a reading after more than ten seconds of stability. This helps with reading the screen in the field, but is not memory storage or a USB export function.
The DO803 has a built-in temperature sensor and eight-pin connector. Its DO8032 luminescent cap and DO8031 storage/calibration sleeve are distinct service parts. There is no electrolyte refill or conventional membrane replacement, but cleaning, humid storage, calibration and eventual cap replacement remain necessary.
Compare DO at defined locations and times without continuously stirring the sample to feed an electrochemical reaction. Record water temperature and salinity assumptions alongside the result. A surface reading alone does not establish oxygen conditions throughout a tank or pond.
The carrying case and cable support portable sampling of compatible general water. Keep a consistent immersion depth, avoid entrained bubbles, and wait for thermal stability. The kit is not an unattended installation or proof of compliance with a particular analytical method.
Use the probe within its 0 to 50°C operating range. The current DO803 specification excludes strong acidic or alkaline water and organic solutions. Select a separately validated method for chemically aggressive samples rather than assuming optical sensing makes every liquid suitable.
Align and secure the eight-pin probe connector, inspect the cap and check the storage sponge. The manual asks for approximately 30 seconds after power-on before operations. No electrochemical polarization warm-up is needed, but this is not an instant-reading guarantee. Select concentration units and enter the correct salinity before sampling.
For saturated-air calibration, dampen the sleeve sponge, attach the sleeve and tighten its locking cap. Keep water droplets off the sensing surface. Allow five to ten minutes for the sleeve atmosphere and temperature to stabilize, then enter calibration and confirm only when the stability symbol remains on. For best accuracy the manual recommends this check before each day of use, despite reduced-calibration marketing language.
Zero calibration is not normally required on first use because it is performed at the factory. Perform it after replacing a probe or cap, after prolonged non-use, or when low-range accuracy at 0 to 2.0 ppm is important. The manual specifies fresh oxygen-free solution made from 2 g anhydrous sodium sulfite in 100 mL distilled or deionized water, effective for one hour; follow its handling and calibration steps.
Remove the sleeve for measurement. Immerse above the probe line, move briefly to release bubbles, then hold still until stable. The 30-second specification describes 90% response at 25°C, not the complete field cycle. The manual describes roughly one minute when temperatures are similar and about three minutes when probe and sample temperatures differ substantially.
The optical cap needs humid storage, not pH-electrode KCl solution. Keep the DO8031 sleeve sponge damp with clean water, not dripping, and close the locking cap. The sensing cap should sit in humid air rather than a pool of water inside the sleeve. Replace a dirty or moldy sponge. For storage beyond 30 days, the manual permits clean-water storage or checking the sleeved sponge every 30 days.
If the sponge has dried or the probe has spent over eight hours in dry air, rehydrate before measuring. The detailed maintenance instructions specify 24 hours in clean water at room temperature, or 48 to 72 hours in cold water. During measurement, remove the sleeve and immerse above the marked immersion line. Do not confuse that sampling depth with the humid-air calibration arrangement.
Protect the cap coating from scratches and temperatures above 50°C. Clean gently with a soft clean cloth; do not use alcohol or organic solvents. The manual describes 3% hydrogen peroxide for 15 to 30 minutes when disinfection is needed, followed by a clean-water rinse. Do not routinely remove or swap sensor caps; keep the interior dry and uncontaminated.
DO8032 is the replacement luminescent cap. Its advertised 8,000-hour service figure is a design estimate, not a guaranteed interval or warranty duration. Replacement requires the correct cap calibration coefficients. The current replacement page describes a probe-connected data box and installation-program flash drive, while the meter manual refers to cap-specific calibration codes. Follow the supplied replacement instructions; neither source establishes a QR-code or RFID procedure.
Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.
Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.
DO850 is the simpler display-and-record choice. Its documented controls provide stable-reading indication and optional HOLD, but no 500-record memory or USB data workflow. Write down the result, units, temperature, sampling location and relevant calibration information in your own field record.
Choose DO8500 instead if timestamped onboard storage, timed recording or the documented USB PC-Link workflow is necessary. Those are different-model functions; the shared optical probe does not add them to DO850.
Related workflow: Apera TN420 Portable White-Light Turbidity Meter. Turbidity and dissolved oxygen describe different water-quality properties; this link is a separate workflow, not a compatible accessory or interchangeable measurement. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.
This is AI480, the nominal 10-ft DO850 kit. The manual calls the DO803 cable 3 m. It is not AI48033 and does not include the 33-ft DO810 cable configuration.
DO850 measures 0 to 20.00 mg/L or ppm, 0 to 200.0% saturation and 0 to 50°C. These are DO and temperature functions, not pH or conductivity ranges.
No. Temperature and pressure are automatic, but salinity must be determined separately and entered manually from 0 to 45 ppt.
No. HOLD locks a stable screen reading. DO850 does not have the DO8500 model’s 500-record storage and USB output.
No. Use saturated-air calibration and follow the manual’s daily recommendation for optimal accuracy. Zero calibration has specific replacement, storage and low-DO use cases.
No. There is no electrolyte to refill, but the cap must remain humid in storage, clean and undamaged. Replace a deteriorated cap using its matching calibration-coefficient procedure.
No instant-reading promise applies. Optical measurement does not need continuous flow, but bubbles and temperature differences still matter. Never exceed the probe’s 50°C limit.
The current exact kit page states three years for the instrument, two years for the DO803 probe excluding its cap, and one year for the DO8032 cap, from purchase. Coverage concerns material or manufacturing defects; improper use, normal wear, accidental damage, storage, transportation and unauthorized repair are excluded. The service-hour estimate is not a warranty.
Review DO850 AI480 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.
Apera Manufacturer Limited Warranty
Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.
Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.