Measure DO, account for salinity and keep up to 500 timestamped records.
Preparing Quote Cart. Your shopping cart stays unchanged.
APERA INSTRUMENTS / DO8500 / AI485
DO8500 adds timestamped storage and automatic salinity compensation to a portable optical DO workflow. The AI485 kit includes the DO803 optical probe with nominal 10-ft cable, a separate salinity electrode and a clip for measuring together. It is designed for general-water sampling where salinity changes and saved results both matter.
Choose DO8500 when manual or timed storage and a salinity input measured by the included electrode are useful. The salinity electrode supports DO compensation; this is not a general pH/EC multiparameter kit.
Each card opens that model page. Match the supplied electrode and documented sample method. pH, conductivity and optical dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.
AI5610
Benchtop pH with records
LabSen 211 pH-only electrode and separate MP500 temperature probe.
AI5612
Benchtop conductivity with records
2301T-F cell and model-specific USB record workflow.
AI5614
Benchtop pH and conductivity
Separate pH and EC probes, each with its own temperature input.
AI502
Straightforward conductivity bench
2301T-F cell and local 50-set recall, without documented USB export.
AI480
Direct optical dissolved oxygen
10-ft DO803 optical probe; stable display and external recordkeeping.
AI485
Optical DO with recording
10-ft optical probe plus salinity electrode and documented logging.
A blue LED excites the luminescent layer; a photodiode detects its red optical response. The probe does not consume oxygen, so measurement does not require continuous sample movement. Still remove bubbles, inspect the cap and allow temperatures to equalize. Optical design is not a guarantee of immediate readings in every sample.
The included 2301-3M conductivity electrode supplies the salinity input used for automatic DO compensation. Connect it and choose automatic mode; use the combined clip to measure with the DO probe. Manual entry from 0 to 45 ppt remains available. Do not assume the optical probe alone measures salinity.
The LCD distinguishes a stable reading, HOLD, M+ saving, RM recall, timed storage and USB communication. The manual shows salinity when its probe is connected and salinity exceeds 1 ppt. HOLD is a reading lock, separate from the commands that actually store records.
The IP57 instrument has a backlight and folding stand, and travels in a carrying case. The DO803 integrates temperature sensing and uses a replaceable optical cap. Protect connectors and seals, and keep the cable clear of sharp edges. The ingress rating does not make every accessory or connected computer waterproof.
Automatic salinity compensation reduces repeated manual entries when moving among waters of different salinity. It depends on the connected, functioning salinity electrode and the selected mode. Record sampling depth and temperature so comparisons reflect a consistent procedure.
Store readings with date and time at successive locations, then preserve location identifiers in your own records. Timed recording can follow a defined sampling interval; it does not by itself establish sample representativeness or replace an installed process sensor.
The stand and probe clip support repeated bench checks. Use compatible aqueous samples within 0 to 50°C. DO803 is not specified for strong acid, strong alkali or organic solutions; determine suitability before applying it to aggressive process liquids.
Connect the DO803 eight-pin plug, secure the connector and inspect the sensing cap. Allow about 30 seconds after power-on before operations. Check the clock if storing data. Select automatic or manual salinity compensation deliberately; automatic mode requires the salinity electrode to be connected, not merely a setting change.
The salinity electrode is factory calibrated. The manual calls for recalibration when it is replaced or has not been used for a long time. In automatic mode use the specified 12.88 mS/cm conductivity standard in the salinity calibration menu, allow the reading to stabilize, then confirm. This standard is for the salinity electrode, not the optical DO saturated-air point.
For DO calibration, use the storage sleeve with a damp, non-dripping sponge. Keep water droplets off the sensor cap and wait five to ten minutes for humidity and temperature to stabilize. Confirm the saturated-air calibration only after the stability icon remains visible. The manual recommends daily saturated-air calibration for optimal accuracy, despite promotional suggestions of infrequent calibration.
Zero calibration is factory performed and normally unnecessary on initial use. It is specified after probe or cap replacement, prolonged non-use, or for demanding work at 0 to 2.0 ppm. Follow the manual’s fresh sodium-sulfite solution procedure. For measurements remove the sleeve, immerse above the marked line, briefly dislodge bubbles and wait for stability. Full equilibration can take about one to three minutes; the 30-second specification is only 90% response at 25°C.
The optical cap needs humid storage, not pH-electrode KCl solution. Keep the DO8031 sleeve sponge damp with clean water, not dripping, and close the locking cap. The sensing cap should sit in humid air rather than a pool of water inside the sleeve. Replace a dirty or moldy sponge. For storage beyond 30 days, the manual permits clean-water storage or checking the sleeved sponge every 30 days.
If the sponge has dried or the probe has spent over eight hours in dry air, rehydrate before measuring. The detailed maintenance instructions specify 24 hours in clean water at room temperature, or 48 to 72 hours in cold water. During measurement, remove the sleeve and immerse above the marked immersion line. Do not confuse that sampling depth with the humid-air calibration arrangement.
Protect the cap coating from scratches and temperatures above 50°C. Clean gently with a soft clean cloth; do not use alcohol or organic solvents. The manual describes 3% hydrogen peroxide for 15 to 30 minutes when disinfection is needed, followed by a clean-water rinse. Do not routinely remove or swap sensor caps; keep the interior dry and uncontaminated.
DO8032 is the replacement luminescent cap. Its advertised 8,000-hour service figure is a design estimate, not a guaranteed interval or warranty duration. Replacement requires the correct cap calibration coefficients. The current replacement page describes a probe-connected data box and installation-program flash drive, while the meter manual refers to cap-specific calibration codes. Follow the supplied replacement instructions; neither source establishes a QR-code or RFID procedure.
Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.
Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.
DO8500 stores up to 500 groups with date and time. Use manual saving for individual samples or set the automatic timing interval for a series. Manual saving is unavailable while timed-storage mode is active. Check the clock before collecting a batch, review records with RM and export before clearing the complete memory.
The exact manual documents DO8500 PC-Link, a Windows driver and COM-port connection, Download and Export to a Microsoft Excel file. In connected real-time operation, readings are sent to the computer rather than retained in meter memory. Keep the computer session and exported file under your own record-retention procedure.
This is the legacy DO8500 workflow, not evidence of compatibility with 9500 software, 480-series software or a browser-based PC-Link service. Verify the delivered meter revision and host-system requirements before purchase if USB use is essential. No software installation, startup or compatibility test is implied, and the kit is not represented as compliance-certified data management.
Related workflow: Apera TN420 Portable White-Light Turbidity Meter. Turbidity and dissolved oxygen describe different water-quality properties; this link is a separate workflow, not a compatible accessory or interchangeable measurement. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.
AI485 is the nominal 10-ft DO8500 kit, with DO803 and a separate salinity electrode. The manual calls the optical cable 3 m. This is not the AI48533 33-ft configuration.
The meter covers 0 to 20.00 mg/L or ppm, 0 to 200.0% saturation and 0 to 50°C. Salinity compensation covers 0 to 45 ppt; automatic pressure compensation covers 60 to 120 kPa.
Included. The manual identifies the supplied electrode as 2301-3M and also lists a combined electrode clip. Automatic compensation requires that sensor to be connected and automatic mode selected.
No pH measurement is specified. The conductivity electrode supports salinity compensation of DO; do not treat this as a general-purpose pH/EC kit.
Up to 500 timestamped groups, using manual or timed storage. HOLD alone does not save a record. Connected real-time PC-Link acquisition is described as storing on the computer, not in the meter.
Browser support is not established by the exact DO8500 sources. Its manual documents legacy Windows PC-Link and a COM-port/driver workflow. Confirm current host compatibility for your meter revision.
No. That is a service-life design estimate, not a guaranteed duration. Coating damage, unsuitable cleaning and dry storage can affect performance. Replacement also requires the correct calibration coefficients.
The current exact kit page states three years for the instrument, two years for the DO803 probe excluding its cap, and one year for the DO8032 cap, from purchase. Coverage concerns material or manufacturing defects; improper use, normal wear, accidental damage, storage, transportation and unauthorized repair are excluded. The service-hour estimate is not a warranty. The linked DO8500 manual instead dates cap coverage from delivery; confirm the applicable terms for your purchase.
Review DO8500 AI485 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.
Apera Manufacturer Limited Warranty
Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.
Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.