Portable pH, practical calibration and a replaceable general-water electrode.
APERA INSTRUMENTS / PH850 / AI5510
The PH850 brings pH and temperature measurement to routine water checks. Its supplied 201T-F electrode combines a protected glass pH sensor and temperature sensing in one replaceable probe. Guided calibration and a stability indicator help you move between field and bench testing.
Choose catalog AI5510 for general aqueous samples and a straightforward, manually documented method. The PH850 is a pH meter, not a conductivity meter; specialized food, pure-water and aggressive-chemical testing needs a separately selected electrode.
Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.
AI5510
General portable pH
201T-F pH/temperature electrode; external measurement records.
AI5512
Portable conductivity and TDS
2301T-S conductivity/temperature probe; no pH claim.
AI5514
pH and EC in one kit
Two separate 201T-F and 2301T-S electrodes.
AI5541
Pure and low-ionic water
Refillable LabSen 803 with movable sleeve.
AI5531
Wastewater and suspensions
LabSen 333 with nonrefillable polymer reference.
AI5539
Small-volume samples
LabSen 243-6 and the conditional semi-micro-container method.
The LCD shows pH alongside temperature, with icons for completed calibrations and reading stability. Automatic hold can freeze a stabilized reading for transcription, but it does not save a sample record for later retrieval.
An IP57-rated instrument body, protective rubber sleeve and folding stand support field and bench work. Keep electrical connectors dry and protect the sensing end from knocks. The rating does not make the glass bulb unbreakable.
The 201T-F uses a lithium-glass sensing membrane, a fiber/ceramic junction and sealed gel reference electrolyte. Its removable shield protects the sensing end. The internal reference needs no refilling; the external storage bottle still needs the correct solution to keep the bulb and junction hydrated.
Make spot checks on compatible process and environmental water samples. Use a consistent sampling location and record temperature with pH to support meaningful comparisons.
Check general nutrient and culture-water solutions where pH guides routine management. This kit does not measure nutrient concentration or conductivity. Compare results against your system’s requirements.
Demonstrate calibration and compare aqueous samples using the stand and readable display. Distilled or deionized water needs a low-ionic-strength method and a more suitable electrode; it is not an ideal accuracy demonstration for the supplied general-water probe.
Connect the blue BNC lead to pH/mV and the black RCA lead to temperature. Remove the storage bottle and rinse the sensing end with distilled or deionized water. Shake off excess water gently without rubbing the glass. The RCA connection supplies the temperature signal needed for automatic compensation.
Use fresh, separate buffer portions. Start with pH 7.00 in the USA series, then add points around the expected sample range. The meter supports one to three calibration points; the electrode instructions call for three points when installing a new probe. Rinse between buffers and wait for the stability indicator before confirming.
Immerse the sensing end and junction, stir briefly to dislodge bubbles, then allow the reading to settle. Record pH and temperature together. Automatic compensation corrects electrode response, not every sample’s own temperature-dependent chemistry. Keep routine testing within the conservative probe limits of 0 to 13 pH and 0 to 60°C; avoid prolonged hot-sample exposure.
After testing, rinse away residue and return the 201T-F to its storage bottle with Apera 3M KCl storage solution, AI1107. Replace cloudy or contaminated solution and tighten the bottle. This is external wet storage, not refilling the sealed gel reference. A separate replenishment bottle is not confirmed as included.
Never use distilled, deionized, RO or tap water for long-term pH-electrode storage. Avoid rubbing the glass membrane or striking the bottom of a vessel. Keep the plug ends clean and dry, and inspect the shield and sensing end before the next calibration.
For persistent contamination, use a cleaning method compatible with both the deposit and the polycarbonate housing. Do not improvise harsh solvents or acid-renewal treatments. If cleaning, reconditioning and fresh buffers do not restore stable calibration, replace the electrode rather than relying on a drifting reading.
Use the physical controls for on-meter measurement and calibration. HOLD temporarily locks a reading on screen; write the result and its sample context in your external worksheet or record system. Screen values in photographs are illustrative, not sample results.
Use calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.
PH850 is a manual-record workflow: its current specification lists data storage and storage content as not applicable. There is no saved-measurement history to recall. Reading hold is a temporary display aid, not a logger or an automatic backup.
Write the sample ID, pH, temperature, operator and observation time in your notebook or chosen record system. Add buffer values and a calibration check before the testing round. Supply the date and time yourself rather than expecting a timestamped meter file.
Check that each value has units and belongs to the right sample. Transcribe or photograph the stable display while the result is available. USB export, PC-Link and Bluetooth are not documented features of this Value model; plan the recordkeeping separately.
Alternative format: Apera PH8500 Premium Series configuration. The Premium Series counterpart offers a different recordkeeping workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.
The kit uses 201T-F, replacement catalog AI1302, with integrated temperature sensing. Its pH connection is BNC and its temperature connection is RCA. It is not an 8-pin pH probe.
No. The internal reference contains gel KCl. Keep the external storage bottle topped up with the specified 3M KCl solution; these are different maintenance tasks.
No. The meter reads 0 to 14.00 pH and compensates from 0 to 100°C. The current probe listing is narrower at 0 to 13 pH and 0 to 60°C.
The USA series recognizes pH 1.68, 4.00, 7.00, 10.01 and 12.45, but a calibration uses at most three points. Recognition does not mean five bottles are supplied.
Yes, in mV mode with a 301Pt-C ORP electrode, sold separately. The supplied 201T-F is the pH/temperature electrode, not an ORP sensor.
No measurement storage is specified, and there is no documented saved-reading recall or export workflow. Use a separate notebook or recording system; automatic hold only freezes the display.
The current US page calls for three AA alkaline batteries, while the linked PH850 manual specifies three AAA; confirm the supplied revision. Battery inclusion is not confirmed. The probe has a storage bottle; a separate bottle of replenishment solution is not listed.
The current US limited warranty is three years for the instrument and six months for the probe from delivery. It covers qualifying defects attributable to Apera, not normal wear, accidental damage, improper storage or failure to follow product instructions.
Review PH850 AI5510 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.
Apera Manufacturer Limited Warranty
Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.
Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.
Use the meter and electrode documents for their stated model and scope. European English editions are labeled where supplied; current US calibration, battery and packing details can differ. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.