Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PC850 Value meter with its supplied electrodes
PC850 angled view showing the folding stand and protective sleeve
201T-F electrode with blue BNC lead, black RCA lead and storage bottle
2301T-S black conductivity electrode with 8-pin lead and storage cap
2301T-S sensing end with labeled platinum-black conductivity cell and temperature sensor
Close photograph of the 201T-F pH sensing end inside its blue protective shield
Open PC850 carrying case with meter, probes and calibration bottles
Apera PC850 Value meter with its supplied electrodes
PC850 angled view showing the folding stand and protective sleeve
201T-F electrode with blue BNC lead, black RCA lead and storage bottle
2301T-S black conductivity electrode with 8-pin lead and storage cap
2301T-S sensing end with labeled platinum-black conductivity cell and temperature sensor
Close photograph of the 201T-F pH sensing end inside its blue protective shield
Open PC850 carrying case with meter, probes and calibration bottles

Apera PC850 Portable pH/Conductivity Meter Kit with Two Electrodes

$499.00

    Separate pH and conductivity probes, practical controls and manual records.

    • 201T-F pH/temperature and 2301T-S conductivity/temperature probes
    • Automatic pH and conductivity calibration with stability indication
    • Conductivity to 200 mS/cm nominal; adjustable TDS factor
    • Three-year instrument and six-month probe limited warranty

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / PC850 / AI5514

Two sensing heads.
One portable water-testing kit.

Measure pH, conductivity and calculated TDS with the PC850 and two separate temperature-sensing electrodes. The 201T-F handles pH; the 2301T-S handles conductivity. A clear LCD and automatic calibration support field and bench water checks, with results documented in your own record system.

Choose catalog AI5514 when you need pH and EC/TDS in one portable kit without a data-logging workflow. Connected electrodes do not mean pH and conductivity appear together: select the measurement mode and read its value alongside temperature.

Apera PC850 Value meter with its supplied electrodes
PC850 with separate pH and conductivity electrodes.
Which 850 Value kit fits my sample?Click or tap to compare all six measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.

Choose the electrode for the sample.

Two electrodes, distinct connections

201T-F connects through BNC for pH and RCA for temperature. 2301T-S uses an 8-pin connection for conductivity and temperature. Each is replaceable. The supplied clip holds the pair; this is not one combined pH/conductivity sensing head.

Make EC and TDS comparisons meaningful

The platinum-black K=1 conductivity cell supports a broad working range. Set a TDS conversion factor from 0.40 to 1.00 for your method; TDS is calculated from conductivity, not a separate direct chemical measurement. Record the factor and reference temperature when comparing results between instruments.

A practical field display

The LCD pairs the selected measurement with temperature and shows stability and calibration icons. Optional automatic hold helps with transcription. The IP57 instrument, protective sleeve and folding stand suit field-to-bench work, but connectors still need protection and both sensing ends need appropriate care.

Know what this configuration supplies.

Included item Order contents
PC850 portable meter One instrument with protective sleeve and folding stand.
201T-F pH/temperature electrode One electrode with BNC/RCA leads and storage bottle.
2301T-S conductivity/temperature electrode One K=1 electrode with 8-pin connector and storage cap.
Electrode clip One clip for the separate probes.
pH calibration buffers 50 mL each of pH 4.00, 7.00 and 10.01.
Conductivity calibration standards 50 mL each of 84 µS/cm, 1413 µS/cm and 12.88 mS/cm.
Screwdriver One, listed for battery replacement.
Carrying case One fitted portable case.
User manual Operating instructions.
Open PC850 carrying case with meter, probes and calibration bottles
PC850 case with separate electrodes and six calibration bottles; see the itemized kit list.

Match the sample and preparation method.

Process-water spot checks

Track pH alongside conductivity in compatible water-treatment and process samples. Standardize sampling and temperature-compensation settings so changes in the method do not masquerade as changes in the water.

Hydroponic solution checks

Use pH for acidity and EC as an indicator of dissolved ionic content in general nutrient solutions. TDS depends on the conversion factor; it does not identify individual nutrients.

Environmental and teaching work

Compare suitable water samples using two clearly separated measurement methods. Very low-conductivity water and concentrated chemicals may need a different electrode or method.

Prepare. Calibrate. Measure.. Connect the correct leads, calibrate with fresh solutions, then record a stable value and temperature.
Connect the correct leads, calibrate with fresh solutions, then record a stable value and temperature.

Calibrate each channel.
Record each selected mode.

Connect both 201T-F leads and align the 2301T-S 8-pin plug before securing its ring. Remove the protective bottles, rinse the sensors and keep their storage liquids separate. Select pH or conductivity as required. Both electrodes can remain connected, but select and document each parameter separately.

Begin pH calibration with pH 7.00 in the USA series, then use additional buffers around the sample range. For conductivity, use fresh standards near the intended range and set the cell constant to K=1 for the supplied electrode. Rinse between solutions; wait for the stability indication before confirming calibration.

Immerse the relevant sensor fully enough to wet its sensing surfaces, stir gently to release bubbles and wait for a stable value. Capture the displayed unit: µS/cm and mS/cm differ by a factor of one thousand. Use the supplied conductivity probe within the 0 to 50°C compensated measurement range.

Understand the sensing end and connections.

201T-F electrode with blue BNC lead, black RCA lead and storage bottle
201T-F: BNC for pH, RCA for temperature, and a sealed gel reference.
2301T-S black conductivity electrode with 8-pin lead and storage cap
2301T-S is a separate K=1 conductivity/temperature electrode, not part of a single pH/EC head.

Different sensors.
Different storage liquids.

The 201T-F has a sealed gel reference that is not refillable. Keep its glass bulb and junction wet in the external bottle using Apera 3M KCl storage solution, AI1107. Replace contaminated liquid. Pure water is suitable for rinsing this pH probe, not for long-term storage.

The 2301T-S instructions specify distilled or deionized water in its storage cap. Rinse before and after testing and replace contaminated cap water. Do not transfer the pH probe’s KCl storage solution to the conductivity cap. Avoid rubbing the conductivity sensor or damaging its platinum-black coating.

Keep connectors clean and dry. Remove residues with compatible gentle cleaning, then rinse and recalibrate. Protect the polycarbonate pH housing from aggressive solvents. A damaged or persistently unstable electrode should be assessed or replaced rather than corrected by an arbitrary offset.

2301T-S sensing end with labeled platinum-black conductivity cell and temperature sensor
2301T-S: the conductivity cell and integrated temperature sensor are distinct sensing surfaces. Avoid rubbing the cell coating.
Close photograph of the 201T-F pH sensing end inside its blue protective shield
Protect the glass sensing end; rinse gently and do not rub the membrane.
Store each sensor correctly. 201T-F: store in Apera 3M KCl. 2301T-S: store in distilled or deionized water. Do not interchange liquids.
201T-F: store in Apera 3M KCl. 2301T-S: store in distilled or deionized water. Do not interchange liquids.
PC850 angled view showing the folding stand and protective sleeve
The folding stand supports bench use without changing the instrument’s field format.
Actual PC850 front photograph showing LCD, keys and model label
The main reading is paired with temperature. The photograph is a display illustration, not a sample result.

A stable reading is the start of the record.

Use the physical controls for on-meter measurement and calibration. HOLD temporarily locks a reading on screen; write the result and its sample context in your external worksheet or record system. Screen values in photographs are illustrative, not sample results.

Use calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Build a paired sample record.

PC850 lists data storage and storage content as not applicable. There is no stored sample history to recall. Automatic hold freezes a displayed reading temporarily; it is not a logger. USB export, PC-Link and Bluetooth are not documented features of this Value model.

For each sample, record its identifier, observation time, pH and temperature, then conductivity with its unit and temperature. If reporting TDS, also record the conversion factor. Add the conductivity reference temperature and compensation coefficient to document the method.

Check the paired entries before moving on. Note calibration standards and unusual sample conditions. Supply dates and times yourself; do not assume the meter creates timestamped files or that a photograph automatically preserves the method settings.

Make the record yourself. Record sample ID, date, time, pH and temperature; for PC850 add EC units and the TDS factor. Reading hold is not stored history.
Record sample ID, date, time, pH and temperature; for PC850 add EC units and the TDS factor. Reading hold is not stored history.

Compare the Premium Series counterpart.

Alternative format: Apera PC8500 Premium Series configuration. The Premium Series counterpart offers a different recordkeeping workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.

PC850 buyer questions

Is there one combined pH/EC probe?

No. AI5514 includes 201T-F pH/temperature, replacement AI1302, and 2301T-S conductivity/temperature, replacement AI1313. They use BNC/RCA and 8-pin connections respectively.

Does it display pH and EC together?

The documented workflow switches the main measurement mode and displays temperature with it. Simultaneous electrode connection is not a promise of concurrent pH and conductivity values on the screen.

Does conductivity reach 1999 mS/cm?

No. This Value meter is specified to 200 mS/cm nominal, with its highest displayed range ending at 199.9 mS/cm. Do not confuse that with 1999 µS/cm. Confirm electrode choice above 100 mS/cm.

Is conductivity accuracy a percent of the reading?

No. The specification is ±1.0% of full scale, plus one digit. Full-scale accuracy is not interchangeable with percent-of-reading accuracy, near the bottom of a range.

Are salinity and resistivity supplied modes?

The current US Value specification supports conductivity and TDS, not a confirmed salinity or resistivity function. Do not select this model on the assumption that it includes those additional modes.

How many standards come with it?

The US kit lists three 50 mL pH buffers and three 50 mL conductivity standards. The recognized calibration values include additional standards; recognition is not an extra-bottle inclusion claim.

What are the supplied probe limits?

Use the narrower current 201T-F listing of 0 to 13 pH and 0 to 60°C. For the 2301T-S, distinguish the broad sensor range from the meter’s 0 to 50°C conductivity compensation range.

What warranty applies?

The current US limited warranty is three years for the instrument and six months for the probe from delivery. It covers qualifying defects attributable to Apera, not normal wear, accidental damage, improper storage or failure to follow product instructions.

Confirm the exact configuration before ordering.

Review PC850 AI5514 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / catalogPC850 / AI5514
    Supplied electrodes201T-F pH/temperature (AI1302) + 2301T-S conductivity/temperature (AI1313)
    ConnectionsBNC pH or ORP; RCA temperature; 8-pin conductivity/temperature
    pH probeSealed gel reference; polycarbonate; fiber-ceramic junction; 30 kΩ thermistor
    pH probe rating used here0 to 13 pH; 0 to 60°C, following the narrower current listing
    Conductivity probePlatinum black; K=1; POM body; 30 kΩ thermistor
    Conductivity probe listingCurrent listing: 0.5 µS/cm to 200 mS/cm; confirm electrode choice above 100 mS/cm; compensated measurement 0 to 50°C
    Instrument pH range0 to 14.00 pH
    pH resolution / accuracy0.1 or 0.01 pH / ±0.01 pH ±1 digit
    pH compensation / calibration0 to 100°C automatic or manual / 1 to 3 points, USA or NIST
    Conductivity meter range0 to 200 mS/cm nominal; highest displayed band 20.0 to 199.9 mS/cm
    Conductivity auto-ranges0 to 19.99 µS/cm; 20.0 to 199.9 µS/cm; 200 to 1999 µS/cm; 2.00 to 19.99 mS/cm; 20.0 to 199.9 mS/cm
    Conductivity accuracy±1.0% FS ±1 digit, not percent of reading
    Conductivity compensation0 to 50°C, automatic or manual
    TDS range / factor0 to 100 g/L / adjustable 0.40 to 1.00
    Selectable cell constants0.1 / 1 / 10 cm⁻¹; supplied electrode K=1
    ORP capability±1000 mV, 1 mV resolution, ±0.2% FS ±1 digit; separate electrode required
    Temperature display0 to 100°C; 0.1°C resolution; ±0.5°C ±1 digit
    Measurement storageNot applicable; manual recordkeeping
    Power requirementBattery-operated; current US page says three AA, manual says three AAA; confirm supplied revision. Battery inclusion is not confirmed.
    ProtectionIP57 instrument; protect connectors and sensing ends
    Limited warrantyThree years instrument / six months probe from delivery

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI5514
    Blue Tiger SKUBTS-AI5514
    Order unit1 exact 850 Value Series kit
    Order contentsPC850 portable meter: One instrument with protective sleeve and folding stand.; 201T-F pH/temperature electrode: One electrode with BNC/RCA leads and storage bottle.; 2301T-S conductivity/temperature electrode: One K=1 electrode with 8-pin connector and storage cap.; Electrode clip: One clip for the separate probes.; pH calibration buffers: 50 mL each of pH 4.00, 7.00 and 10.01.; Conductivity calibration standards: 50 mL each of 84 µS/cm, 1413 µS/cm and 12.88 mS/cm.; Screwdriver: One, listed for battery replacement.; Carrying case: One fitted portable case.; User manual: Operating instructions.

    Apera Manufacturer Limited Warranty

    Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.

    Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.

    PC850 official documents

    Use the meter and electrode documents for their stated model and scope. European English editions are labeled where supplied; current US calibration, battery and packing details can differ. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat