Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments
Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions Value Portable pH Meter Apera Instruments

Apera PH850-SA Portable pH Meter Kit with LabSen 843 for Strong Alkali and High-Salinity Solutions

$399.00

    Portable pH measurement for strong alkalis and high-salinity samples, with a refillable LabSen 843.

    • LabSen 843: HA-type glass for pH 10–14 samples
    • Silver-ion-trap reference and ceramic junction
    • Built-in temperature sensor through BNC/RCA leads
    • No memory: HOLD the reading and log it by hand

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH850-SA / AI5527

Strong alkali and high salinity.
Start with the right glass.

The PH850-SA pairs Apera’s portable PH850 meter with the Swiss LabSen 843 refillable pH/temperature electrode. Apera designs the 843 for high-precision pH measurement of strong alkaline solutions (pH 10–14) and high-salinity solutions, using an HA-type glass membrane to minimize alkaline error and a silver-ion-trap reference to prevent junction clogs.

Choose AI5527 when the sample chemistry, rather than portability alone, decides the electrode. Apera lists the LabSen 843 at 2–14 pH and 0–100°C for this kit. Those are the electrode’s working limits, not a promise about every caustic mixture. Automatic temperature compensation corrects the electrode response; it does not stop a caustic sample from absorbing carbon dioxide from air.

Apera PH850 portable meter with the supplied LabSen 843 pH/temperature electrode
PH850 meter with the supplied LabSen 843. Display values are illustrative, not a sample result.
Which 850 Value kit fits my sample?Click or tap to compare all nine configurations, including harsh-chemistry kitsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.

Harsh-chemistry kits

Choose the electrode for the sample.

HA-type glass for strong alkalis

Ordinary pH glass responds partly to sodium ions at high pH, so readings drift low. Apera specifies an HA-type membrane on the LabSen 843 to minimize that alkaline error in pH 10–14 samples. The membrane is a hemispherical bulb; protect it from impact and keep it hydrated.

Silver-ion-trap reference, ceramic junction

The reference system traps silver ions before they reach the ceramic junction, which Apera describes as preventing junction clogs. The junction still needs clean samples, rinsing and wet storage.

Refillable, with a built-in temperature sensor

The 843 uses 3M KCl reference solution that you top up through the refill hole, and a 30 kΩ NTC sensor wired to a separate RCA plug. Connect both the BNC and RCA leads so the meter can display sample temperature and apply automatic compensation.

Know what this configuration supplies.

Included item Order contents
PH850 portable meter One Value-series pH/mV/temperature meter with folding stand and IP57 enclosure.
LabSen 843 pH/temperature electrode One electrode (replacement AI3179) with storage bottle, BNC pH lead and RCA temperature lead.
pH buffer solutions pH 4.00, 7.00 and 10.01, 50 mL each, per the PH850 kit list. The pH 1.68 and 12.45 buffers are sold separately.
Portable carrying case Apera lists the case at 330 × 270 × 82 mm and 1.3 kg.
User manual Meter instructions; the electrode manual is linked under Manuals/Brochures.

Kit list follows the PH850 manual, with the specialty electrode supplied in place of the general-purpose 201T-F. Packing can vary slightly by production revision.

Apera LabSen HA glass membrane graphic
Apera graphic for the LabSen HA glass membrane: corrosion resistance for strong alkaline solutions and high-temperature resistance to 130°C.

Where this configuration fits.

Use the PH850-SA for strong alkaline solutions in the pH 10–14 region and for high-salinity samples where a general-purpose electrode is likely to read low. Typical examples are caustic cleaning and process solutions, alkaline reagents and brines, measured within the electrode’s 2–14 pH and 0–100°C limits.

If the sample is also hot, complex or an electroplating bath, compare the PH850-HT with LabSen 863. For strong acids and fluoride-containing samples, the PH850-HF with LabSen 833 is the matching configuration. Apera’s manual advises against using the 843 in strong acids and dehydrating media such as absolute ethanol and concentrated sulfuric acid.

PH850 manual Chart 4 three-point calibration mode
PH850 manual Chart 4. The first point is always 7.00 pH (6.86 NIST); the second and third points are chosen for the sample range.

Calibrate above pH 7.
Then measure a stable sample.

Connect the electrode’s BNC plug to the pH input and the black RCA plug to the temperature input. Twist off the storage bottle cap, pull out the electrode, rinse it with distilled or deionized water and open the blue rubber plug on the refill hole so the reference solution flows smoothly.

Apera specifies at least a two-point calibration before a new electrode is used. The PH850 always starts at 7.00 pH (6.86 pH in the NIST series). For alkaline work, add 10.01 pH or 12.45 pH as the second point; a three-point calibration can use 4.00, 7.00 and 10.01 or 12.45 pH. The kit supplies 4.00, 7.00 and 10.01 pH; add 12.45 pH buffer when samples sit near the top of the range.

Immerse the bulb and junction, stir gently and wait for the stability icon before reading. Strong bases absorb carbon dioxide from air and drift downward, so keep samples covered and measure promptly. Strong alkali is corrosive: wear eye and skin protection.

PH850 manual list of conditions that require recalibration
The PH850 manual requires recalibration after acid (pH < 2) or alkaline (pH > 12) samples, fluoride-containing solutions, a new or long-idle probe, and large temperature differences between sample and buffer.

Understand the sensing end and connections.

LabSen 843 manual diagram labeling the refill-hole plug, storage bottle cap, measuring tip, storage bottle and RCA and BNC connectors
LabSen 843 manual diagram: refill-hole rubber plug, storage bottle cap, measuring tip and storage bottle, with separate RCA (temperature) and BNC (pH) connectors.
Close-up of the LabSen 843 hemispherical HA glass bulb and ceramic junction
Actual LabSen 843 sensing end: the blue-filled hemispherical HA glass bulb and the ceramic junction above it. Keep both immersed during measurement.

Refill with 3M KCl.
Store the glass wet.

When the electrode is not in use, keep it in the storage bottle with 3M KCl soaking solution (Apera AI1107). Replace the solution if it becomes contaminated. Distilled and deionized water are rinse liquids, not storage liquids; never store the 843 in pure water.

The reference solution runs down with use. When it falls to about half the electrode height, unplug the blue rubber plug and add 3M KCl through the refill hole with a syringe or pipette. After measuring, return the electrode to its bottle, tighten the cap and close the refill hole.

Keep the BNC and RCA connectors clean and dry. Apera puts typical pH-electrode service life at 12–24 months and recommends replacement every 12–18 months; frequent strong-alkali work sits at the demanding end of that range. The replacement electrode is LabSen 843, AI3179.

LabSen 843 manual storage and refilling instructions
LabSen 843 manual: store in 3M KCl (AI1107), never in pure water, and refill with 3M KCl at half height.
LabSen 843 manual rinsing and cleaning instructions
For tough contamination, the manual specifies Apera cleaning solution AI1166 for 30 minutes, a soft brush, then at least one hour in 3M KCl before rinsing and recalibrating. Cleaning solution is sold separately.

A closer look at the LabSen 843 design.

Apera silver ion trap reference system graphic
Apera graphic: the silver ion trap absorbs exuded Ag⁺ so it does not clog the junction. The same reference system is used across the LabSen 833, 843 and 863.
Apera graphic comparing the LabSen 843 sturdy glass membrane with conventional membranes
Apera graphic: Apera rates the LabSen 843’s sturdy glass membrane ten times stronger than traditional glass membranes. It is still glass; avoid impact.
PH850 portable meter on its folding stand with electrode connected
Shared PH850 meter on its folding stand. Display values are illustrative.

Read it. Record it.
Keep your own sample log.

The PH850 is Apera’s Value-series portable: a backlit LCD with stability and calibration icons, folding stand, IP57 enclosure and automatic power-off. It measures 0.00 to 14.00 pH at 0.01 or 0.1 pH resolution with ±0.01 pH ±1 digit accuracy, ±1000 mV in mV mode, and temperature from 0 to 100°C with automatic or manual compensation.

There is no data memory, clock or computer output on the PH850. The HOLD function freezes a stable reading on screen; write the value, temperature, sample identity and calibration check into your own log. If stored, time-stamped records matter, see the Premium Series counterpart below.

LabSen 843 manual technical specifications table
LabSen 843 manual specification table. Apera’s kit page lists 0–100°C for the electrode in this kit, matching the meter’s compensation range.

Check the electrode limits.
Then the meter’s.

Apera lists the LabSen 843 in this kit at 2–14 pH and 0–100°C, with an HA hemispherical membrane, ceramic junction, silver-ion-trap reference, 3M KCl electrolyte, 30 kΩ NTC temperature sensor, lead-free glass body (Ø12 × 120 mm), membrane resistance below 500 MΩ, a 1 m cable and BNC plus RCA connectors.

The meter’s automatic temperature compensation covers 0–100°C. Keep samples, buffers and the electrode within those limits, and confirm suitability with Apera’s documentation before measuring unusual chemistries.

Compare the Premium Series counterpart.

Related configuration: Apera PH8500-SA Premium Series Kit with LabSen 843 (AI5523). It supplies the same electrode with the PH8500 meter, which adds 500-set data memory with date and time, a calibration reminder and USB export through PC-Link. Choose the PH850-SA when direct readings and a hand-kept log are enough.

PH850-SA buyer questions

Which electrode comes with PH850-SA?

The Swiss LabSen 843 refillable pH/temperature electrode, replacement SKU AI3179. It has an HA-type glass membrane, ceramic junction, silver-ion-trap reference, 3M KCl electrolyte and a built-in 30 kΩ NTC temperature sensor.

What pH and temperature range does the electrode cover?

Apera lists 2–14 pH and 0–100°C for the LabSen 843 in this kit, and designs it for strong alkaline solutions from pH 10 to 14. The meter’s wider display range does not extend the electrode’s limits.

Why does a strong-alkali sample need a special electrode?

At high pH and high sodium concentration, general-purpose pH glass responds partly to sodium ions and reads lower than the true pH. The 843’s HA-type membrane is formulated to minimize that alkaline error.

Which buffers should I use?

Start at pH 7.00, then use 10.01 pH, or 12.45 pH for samples near the top of the range. The kit includes pH 4.00, 7.00 and 10.01 buffers; pH 12.45 buffer is sold separately.

Is the electrode refillable, and how do I store it?

Yes. Refill the reference with 3M KCl (AI1107) when it falls to about half height, and store the electrode in its bottle with 3M KCl. Never store it in distilled or deionized water.

Can I use it in strong acids?

Apera’s manual says the 843 should avoid strong acids and dehydrating media. For strong acids and fluoride-containing samples, use the PH850-HF with LabSen 833.

Can the PH850 store readings?

No. The PH850 has no data memory, clock or computer output. HOLD freezes a stable reading on screen; record it in your own log. The PH8500 counterpart adds 500-set memory and USB export.

What warranty applies?

Apera provides a limited warranty of three years on the meter and six months on the electrode from delivery, excluding wear, misuse and the other causes listed in Apera’s terms. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific.

Confirm the exact configuration before ordering.

Review PH850-SA AI5527 against the sample chemistry, supplied LabSen 843 and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / catalogPH850-SA / AI5527
    Included electrodeLabSen 843; replacement AI3179
    Electrode operating range2–14 pH; 0–100°C
    Body / membraneLead-free glass / HA-type glass, hemispherical bulb
    Reference / junctionSilver ion trap / ceramic junction
    Reference fill / external storage3M KCl, refillable / 3M KCl, AI1107
    Temperature sensor / connectorsBuilt-in NTC 30 kΩ / BNC pH + RCA temperature
    Electrode dimensions / cableØ12 × 120 mm / 1 m
    Membrane resistance< 500 MΩ
    Meter pH range / resolution0.00 to 14.00 pH / 0.01 or 0.1 pH
    Meter pH accuracy±0.01 pH ±1 digit
    pH calibration1–3 points; first point 7.00 pH (6.86 NIST); USA or NIST buffer series
    Temperature compensation0–100°C, automatic or manual
    mV range / resolution / accuracy±1000 mV; 1 mV; ±0.2% F.S. ±1 digit
    Temperature range / resolution / accuracy0 to 100°C; 0.1°C; ±0.5°C ±1 digit
    Data storageNone; HOLD freezes the display, record by hand
    Output / softwareNone
    Power3 × AAA batteries (per the PH850 manual)
    ProtectionIP57 dustproof and waterproof
    Meter size / weight86 × 196 × 33 mm / 335 g
    Kit with case330 × 270 × 82 mm / 1.3 kg
    Manufacturer limited warrantyThree years for meter; six months for electrode, from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI5527
    Blue Tiger SKUBTS-AI5527
    Order unit1 PH850-SA portable pH meter kit
    Order contentsPH850 meter; LabSen 843 pH/temperature electrode with storage bottle; pH 4.00, 7.00 and 10.01 buffers (50 mL each); carrying case; user manual

    Apera Manufacturer Limited Warranty

    Apera Instruments provides a limited three-year warranty on the instrument and a six-month warranty on the supplied electrode, from delivery, covering defects attributable to the manufacturer under its stated conditions.

    Normal wear (including electrode membrane wear from aggressive samples), accidental damage, improper use or storage, transport damage, failure to follow instructions and unauthorized repair or modification are excluded. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific. Keep your order details when requesting service.

    PH850-SA official documents

    Manufacturer instructions for the meter and the supplied electrode. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat