Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 835 – 8-pin for PH60 PH60Z pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 831 – BNC pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 833 – BNC RCA with temp sensor pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 835 – 8-pin for PH60 PH60Z pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 831 – BNC pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions pH Electrode Apera Instruments
Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions LabSen 833 – BNC RCA with temp sensor pH Electrode Apera Instruments

Apera LabSen 831 / 833 / 835 pH Electrode for Strong Acids and HF-Containing Solutions

$159.00

    Hydrofluoric acid etches glass. This membrane resists it.

    • Strong acids, HF
    • 831/833: pH 0–11; 835: pH 0–12; electrode 0–100°C, subject to host/HF limits
    • Versions: 831 BNC; 833 BNC/RCA; 835 8-pin (PH60/PH60Z require installed socket/adapter)
    • HF glass; sample tests <0.1 mol/L, <1 minute; PTFE container

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / LABSEN 831 · 833 · 835 / AI3109 / AI3177 / AI3239

Hydrofluoric acid etches glass.
This membrane resists it.

LabSen 831, 833 and 835 measure strong acid samples and solutions containing hydrofluoric acid. Their HF glass membrane resists hydrofluoric corrosion, and a silver ion trap reference extends service life. The 831 (BNC) and 833 (BNC/RCA with temperature) are refillable with a ceramic junction and 3M KCl; the 835 is the non-refillable 8-pin version for PH60 and PH60Z testers fitted with the required 8-pin socket/adapter.

Listed operating envelope: pH 0–11 for 831/833 (conservative manual limits); pH 0–12 for 835; electrode/sample temperature 0–100°C, subject to host limits and the separate HF exposure restrictions. Choose the version that matches your meter’s connection and temperature requirements from the menu above. Apera warrants LabSen electrodes for six months from delivery.

Apera LabSen 831 · 833 · 835 pH electrode
Apera LabSen 831 · 833 · 835.
Choose your LabSen electrode: demanding chemistryClick or tap to compare 8 electrode familiesCompare the models below - click or tap here to close

Only published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.

Pick the version
that fits your meter.

Version Connector and build
LabSen 831 · AI3109 BNC connector, no temperature sensor; refillable; ceramic junction, 3M KCl electrolyte.
LabSen 833 · AI3177 BNC + RCA plugs, built-in 30 kΩ NTC temperature sensor; refillable; ceramic junction, 3M KCl electrolyte.
LabSen 835 · AI3239 8-pin connector, built-in 30 kΩ NTC temperature sensor; non-refillable; open junction, polymer electrolyte.

BNC versions connect to the pH input of BNC pH meters. They have no temperature sensor: use a separate temperature probe supported by the host meter (Apera’s MP500 only where the meter supports it), or manual temperature entry where available.

BNC/RCA versions carry a built-in 30 kΩ NTC temperature sensor on an RCA plug for automatic temperature compensation on Apera meters with BNC and RCA inputs, such as the PH700, PH850, PH8500, PH820, PH910 and PH9500. Apera notes they may not work with other brands’ meters because the thermistor might not be compatible.

The 8-pin version is a pH/temperature electrode for Apera meters with an 8-pin socket, including the PH60, PH60-Z, PH400, PH400S and the PC400, PC400S, SX736 and SX751. PH60 and PH60Z require the appropriate installed 8-pin socket/adapter; this cabled electrode does not replace the native tester probe directly. Confirm the adapter separately; its inclusion is not implied.

Temperature figures are electrode/sample ratings, not a complete-system rating. Use a meter and temperature-compensation method rated for the actual sample temperature; keep the meter body, cable connection and adapter within their own confirmed limits. Connector fit alone does not establish temperature or ATC compatibility.

What makes it work.

HF glass membrane

Designed for strong acid samples and resistant to hydrofluoric corrosion. Apera rates the 833 and 835 for about 1,000 HF measurements within its limits.

Silver ion trap reference

Keeps the reference free of silver ions that would clog the junction.

Apera’s HF limit

HF concentration below 0.1 mol/L (about 2000 ppm), with each measurement under one minute. Sample tests only, not continuous monitoring. Use a PTFE container for HF; the product graphics are not handling instructions.

Apera LabSen 831 feature graphic
From Apera’s LabSen product graphics.

Check the specifications.

Operating envelope: pH 0–11 for 831/833 (conservative manual limits); pH 0–12 for 835; electrode/sample temperature 0–100°C, subject to host limits and the separate HF exposure restrictions. Common construction: body lead-free glass.

Junction: 831 ceramic; 833 ceramic; 835 open.

Reference electrolyte: 831 3M KCl; 833 3M KCl; 835 polymer.

The full specification table is in the Product Specifications tab. The 831/833 product pages list pH 0–12, but their exact manuals list 0–11; this page adopts the narrower 0–11 for those two models. Older 831/833 manuals describe broader HF exposure conditions; this page retains the stricter current-page limits for all three. A concentration, time or temperature limit must not be treated as proof that every combination is suitable.

Apera LabSen 831 dimension drawing
LabSen 831 dimensions, from Apera.

Store it wet.
Keep it clean.

Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring.

Never store a pH electrode in pure, deionized or distilled water.

The 831 and 833 are refillable: keep the fill hole open while measuring and top up the reference electrolyte when the level drops.

The 835 is sealed and needs no refilling.

Apera’s manual advises avoiding strong alkaline solutions and dehydrating media; if exposure is unavoidable, keep immersion short and clean the electrode carefully afterward.

Rinse with distilled or deionized water between samples. For stubborn deposits, use Apera electrode cleaning solution, then recondition and recalibrate.

Related items.

Apera ships this electrode in these kits: PH850-HF (LabSen 833), PH8500-HF (LabSen 833), PH700-HF (LabSen 833), PH60-HF (LabSen 835), PH60Z-HF (LabSen 835).

Calibrate with fresh pH 7.00, pH 4.00 and pH 10.01 buffers, or pH 1.68 for the acid side.

LabSen 831 · 833 · 835 buyer questions

What is the LabSen 831 / 833 / 835 made for?

LabSen 831, 833 and 835 measure strong acid samples and solutions containing hydrofluoric acid.

Which version do I need?

831 has BNC for pH only; 833 adds an RCA-connected 30 kΩ NTC temperature sensor for a compatible Apera meter; 835 uses Apera’s 8-pin connection. PH60/PH60Z need the appropriate installed 8-pin socket/adapter, not a direct native-probe swap. Check host compatibility and adapter supply before ordering.

Will the BNC/RCA version work on another brand’s meter?

The pH signal uses BNC, but the built-in 30 kΩ NTC temperature sensor is not universally compatible. Apera lists meters with matching BNC/RCA inputs; verify the meter’s thermistor support and temperature range before relying on ATC.

Is it refillable?

The 831 and 833 are refillable; the 835 is sealed.

How should I store it?

Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring. Never use pure, deionized or distilled water.

How much HF can it handle?

Use only spot/sample measurements below 0.1 mol/L HF (about 2000 ppm), each under one minute, in a PTFE container. Do not leave the electrode in HF for continuous monitoring or storage. Older 831/833 manuals give broader conditions; this page deliberately uses the stricter current-page limits and does not extend those older instructions to 835.

What warranty applies?

Apera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.

Can I use the full 0–100°C range with my tester?

Not from the electrode rating alone. The 831/833 are listed here at pH 0–11 and 835 at pH 0–12; all have a 0–100°C electrode rating, but the host meter, ATC and connector have their own limits. PH60’s manual lists ATC at 0–50°C. Confirm the exact PH60Z configuration rather than treating a probe rating as a system rating; HF contact restrictions still apply.

Confirm the exact configuration before ordering.

Check the version, connector and catalog number (AI3109 / AI3177 / AI3239) against your meter and samples, then return to the live price and ordering controls.

Back to price and ordering ↑

    Temperature figures are electrode/sample ratings, not a complete-system rating. Use a meter and temperature-compensation method rated for the actual sample temperature; keep the meter body, cable connection and adapter within their own confirmed limits. Connector fit alone does not establish temperature or ATC compatibility.

    SpecificationDetail
    ModelLabSen 831 / 833 / 835
    Connector831: BNC; 833: BNC/RCA; 835: 8-pin
    Temperature sensor831: none; 833: 30 kΩ NTC; 835: 30 kΩ NTC
    pH range831/833: 0–11 (conservative exact-manual limits); 835: 0–12
    Temperature range0–100°C electrode/sample rating; host and HF exposure limits apply
    BodyLead-free glass
    Glass membrane831: HF, hemispherical; 833: HF, half-ball; 835: HF, hemispherical
    Junction831: Ceramic; 833: Ceramic; 835: Open
    Reference systemSilver ion trap
    Reference electrolyte831: 3M KCl; 833: 3M KCl; 835: Polymer
    Refillable831: Yes; 833: Yes; 835: No
    DimensionsØ12 × 120 mm
    Membrane impedance831: <400 MΩ; 833: <400 MΩ; 835: <500 MΩ
    Cable3 ft
    Manufacturer warrantySix months from delivery against defects in material and workmanship

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3109 / AI3177 / AI3239
    Blue Tiger SKUBTS-AI3109 / BTS-AI3177 / BTS-AI3239
    VersionsLabSen 831 – BNC: AI3109; LabSen 833 – BNC/RCA with temp sensor: AI3177; LabSen 835 – 8-pin for PH60/PH60Z with required installed socket/adapter: AI3239
    Order unit1 electrode

    Warranty Information

    APERA INSTRUMENTS, LLC warrants LabSen electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

    LabSen 831 · 833 · 835 official documents

    Model-specific manuals for 831 and 833 only; these are not a universal 835 manual. Each card opens a PDF. The 831/833 PDFs list pH 0–11, adopted here, and describe broader HF contact conditions than the current product pages. Use this listing’s stricter HF limits: below 0.1 mol/L and under one minute, sample tests only, in a PTFE container. Do not transfer older 831/833 HF conditions to 835.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat