Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 801 – BNC pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 803 – BNC RCA with temp sensor pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 805 – 8-pin for PH60 PH60Z pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 801 – BNC pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 803 – BNC RCA with temp sensor pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions LabSen 805 – 8-pin for PH60 PH60Z pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments
Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions pH Electrode Apera Instruments

Apera LabSen 801 / 803 / 805 pH Electrode for Pure Water and Low Ionic Strength Solutions

$216.00

    Pure water barely conducts. This glass is built for it.

    • Pure, DI and RO water
    • pH 1–11, 0–80°C
    • Versions: 801 BNC; 803 BNC/RCA; 805 8-pin
    • L-type glass membrane

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / LABSEN 801 · 803 · 805 / AI3108 / AI3137 / AI3233

Pure water barely conducts.
This glass is built for it.

LabSen 801, 803 and 805 measure pH in pure water such as distilled, deionized and RO water and other low ionic strength solutions, where ordinary electrodes drift. All three use Apera’s L-type low-resistance glass (<50 MΩ) and read pH 1–11. The 801 (BNC) and 803 (BNC/RCA with temperature) are refillable with a movable sleeve junction; the 805 is the non-refillable 8-pin version with triple ceramic junctions for the PH60 and PH60Z testers.

It reads pH 1 to 11 from 0 to 80°C. Choose the version that matches your meter’s connector from the menu above. Apera warrants LabSen electrodes for six months from delivery.

Apera LabSen 801 · 803 · 805 pH electrode
Apera LabSen 801 · 803 · 805.
Choose your LabSen electrode: water and labClick or tap to compare 7 electrode familiesChoose an item below - click or tap here to close

Pick the version
that fits your meter.

Version Connector and build
LabSen 801 · AI3108 BNC connector, no temperature sensor; refillable; movable sleeve junction, 3M KCl electrolyte.
LabSen 803 · AI3137 BNC + RCA plugs, built-in 30 kΩ NTC temperature sensor; refillable; movable sleeve junction, 3M KCl electrolyte.
LabSen 805 · AI3233 8-pin connector, built-in 30 kΩ NTC temperature sensor; non-refillable; ceramic × 3 junction, KCl electrolyte.

BNC versions plug into any pH meter with a BNC input. They have no temperature sensor, so pair them with a separate temperature probe such as Apera’s MP500 for automatic temperature compensation, or enter the temperature manually.

BNC/RCA versions carry a built-in 30 kΩ NTC temperature sensor on an RCA plug for automatic temperature compensation on Apera meters with BNC and RCA inputs, such as the PH700, PH850, PH8500, PH820, PH910 and PH9500. Apera notes they may not work with other brands’ meters because the thermistor might not be compatible.

The 8-pin version is a pH/temperature electrode for Apera meters with an 8-pin socket, including the PH60, PH60-Z, PH400, PH400S and the PC400, PC400S, SX736 and SX751.

Apera LabSen 805 pH electrode
LabSen 805.

What makes it work.

L-type glass membrane

Low-resistance formula below 50 MΩ. Apera expects stable readings in about 30–60 seconds in low ionic strength solutions.

Sleeve or triple-ceramic junction

The 801 and 803 use a movable sleeve whose outflow adjusts with sleeve tightness; the 805 uses three ceramic junctions for faster electrolyte discharge.

Silver ion trap

On the 801 and 803, a silver ion trap added to the reference system reduces junction clogging.

Apera LabSen 801 feature graphic
LabSen 801 sensing tip.

Check the specifications.

All versions share: pH range 1–11; temperature range 0–80°C; body lead-free glass.

Junction: 801 movable sleeve; 803 movable sleeve; 805 ceramic × 3.

Reference electrolyte: 801 3M KCl; 803 3M KCl; 805 KCl.

Dimensions: 801 Ø12 × 130 mm; 803 Ø12 × 130 mm; 805 Ø12 × 120 mm.

The full specification table is in the Product Specifications tab.

Store it wet.
Keep it clean.

Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring.

Never store a pH electrode in pure, deionized or distilled water.

The 801 and 803 are refillable: keep the fill hole open while measuring and top up the reference electrolyte when the level drops.

The 805 is sealed and needs no refilling.

Apera’s manual advises avoiding strong acids, strong alkalis and dehydrating media such as absolute ethanol or concentrated sulfuric acid; if exposure is unavoidable, keep immersion short and clean the electrode carefully afterward.

Rinse with distilled or deionized water between samples. For stubborn deposits, use Apera electrode cleaning solution, then recondition and recalibrate.

Related items.

Apera ships this electrode in these kits: PH700-PW (LabSen 803), PH8500-PW (LabSen 803), PH850-PW (LabSen 803), PH60-PW (LabSen 805), PH60Z-PW (LabSen 805).

Calibrate with fresh pH 7.00, pH 4.00 and pH 10.01 buffers.

LabSen 801 · 803 · 805 buyer questions

What is the LabSen 801 / 803 / 805 made for?

LabSen 801, 803 and 805 measure pH in pure water such as distilled, deionized and RO water and other low ionic strength solutions, where ordinary electrodes drift.

Which version do I need?

Match the connector to your meter: BNC for any BNC pH meter (no temperature sensor), BNC/RCA for Apera meters with BNC and RCA inputs (built-in temperature sensor), or 8-pin for the PH60 and PH60Z testers and other Apera 8-pin meters.

Will the BNC/RCA version work on another brand’s meter?

The pH signal is standard BNC, but Apera notes the temperature thermistor may not be compatible with other brands’ meters. Use it on Apera meters with BNC and RCA inputs.

Is it refillable?

The 801 and 803 are refillable; the 805 is sealed.

How should I store it?

Keep the tip in its cap with 3M KCl storage solution whenever it is not measuring. Never use pure, deionized or distilled water.

What warranty applies?

Apera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.

Confirm the exact configuration before ordering.

Check the version, connector and catalog number (AI3108 / AI3137 / AI3233) against your meter and samples, then return to the live price and ordering controls.

Back to price and ordering ↑
    SpecificationDetail
    ModelLabSen 801 / 803 / 805
    Connector801: BNC; 803: BNC/RCA; 805: 8-pin
    Temperature sensor801: none; 803: 30 kΩ NTC; 805: 30 kΩ NTC
    pH range1–11
    Temperature range0–80°C
    BodyLead-free glass
    Glass membrane801: L-type, cylindrical; 803: L-type; 805: L-type, olive
    Junction801: Movable sleeve; 803: Movable sleeve; 805: Ceramic × 3
    Reference system801: Silver ion trap; 803: Silver ion trap; 805: Long-Life
    Reference electrolyte801: 3M KCl; 803: 3M KCl; 805: KCl
    Refillable801: Yes; 803: Yes; 805: No
    Dimensions801: Ø12 × 130 mm; 803: Ø12 × 130 mm; 805: Ø12 × 120 mm
    Membrane impedance<50 MΩ
    Cable3 ft
    Manufacturer warrantySix months from delivery against defects in material and workmanship

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3108 / AI3137 / AI3233
    Blue Tiger SKUBTS-AI3108 / BTS-AI3137 / BTS-AI3233
    VersionsLabSen 801 – BNC: AI3108; LabSen 803 – BNC/RCA with temp sensor: AI3137; LabSen 805 – 8-pin for PH60/PH60Z: AI3233
    Order unit1 electrode

    Warranty Information

    APERA INSTRUMENTS, LLC warrants LabSen electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

    LabSen 801 · 803 · 805 official documents

    Apera user manuals for the LabSen 801 · 803 · 805. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat