Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Default Title Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX731 Portable pH/ORP/Conductivity Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX731 Portable pH/ORP/Conductivity Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Default Title Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX731 Portable pH/ORP/Conductivity Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX731 Portable pH/ORP/Conductivity Meter Kit Portable Multiparameter Meter Apera Instruments
Apera SX736 Portable pH/Conductivity/DO Meter Kit Portable Multiparameter Meter Apera Instruments

Apera SX751 Portable pH/ORP/Conductivity/DO Meter Kit

$795.00

    Swap probes, confirm stability and save selected readings in 400-set internal memory.

    • 201T-S, 301Pt-S, 2301T-S and DO500 supplied with 8-pin connections
    • Single electrode input with automatic mode recognition
    • 400 stored sets with manual save and recall
    • Polarographic DO with membrane caps and electrolyte

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / SX751 / AI469

Four measurement methods.
One portable kit.

SX751 combines pH, ORP, conductivity and dissolved oxygen testing in a battery-powered carrying-case kit. Connect the appropriate supplied electrode, let the meter recognize its mode, and take one measurement at a time. Conductivity also supports TDS, salinity and resistivity displays; these are related outputs, not additional independent probes. Temperature accompanies supported electrode measurements.

Choose AI469 for sequential spot checks with replaceable 201T-S, 301Pt-S, 2301T-S and DO500 electrodes and on-meter recall. The kit includes polarographic DO500, not an optical oxygen sensor. A dedicated 301Pt-S ORP electrode is supplied as well. It is not a simultaneous multichannel logger or a wireless app-based tester.

SX751 meter with its supplied probes, shown together for identification. One probe connects at a time; this is not a simultaneous multi-channel arrangement. Screen values are manufacturer examples.
SX751 meter with its supplied probes, shown together for identification. One probe connects at a time; this is not a simultaneous multi-channel arrangement. Screen values are manufacturer examples.
Which meter kit fits my measurement?Click or tap to compare all eight measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, ORP, conductivity and polarographic dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Apera SX711

SX711

AI460

pH and temperature

201T-S pH/temperature probe; ORP electrode separate.

View SX711 →
Apera SX721

SX721

AI463

pH and ORP kit

Separate pH and ORP probes; one connection at a time.

View SX721 →
Apera SX723

SX723

AI477

pH and conductivity kit

Separate 201T-S and 2301T-S probes; sequential tests.

View SX723 →
Apera SX716

SX716

AI461

Polarographic dissolved oxygen

DO500 membrane probe; polarization and movement required.

View SX716 →
Apera SX725

SX725

AI465

pH and dissolved oxygen

Swap the pH and DO500 probes for sequential tests.

View SX725 →
Apera SX731

SX731

AI467

pH, ORP and conductivity

Three supplied sensor types; not simultaneous acquisition.

View SX731 →
Apera SX736

SX736

AI468

pH, conductivity and DO

Three probe workflows with distinct storage and calibration.

View SX736 →
Apera SX751

SX751

AI469

pH, ORP, conductivity and DO

Four probe workflows; one input and model-specific records.

Current item

Choose the electrode for the sample.

Recognize the electrode, then select the display

Automatic recognition selects the measurement family for the connected probe. Use the keypad to choose conductivity, TDS, salinity or resistivity, and the desired resolution or units. This changes the displayed result, not the number of sensors connected. The backlit LCD includes temperature, stability, calibration and memory indicators.

Keep instrument range separate from probe suitability

The pH meter spans -2.00 to 19.99 pH, but the current US 201T-S probe page specifies 0 to 13 pH and 0 to 60°C. It is intended for general aqueous samples, not every solution within the meter display range. Older probe instructions show wider limits; use the conservative current probe specification when selecting an application. The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.

Conductivity with an identifiable cell

The supplied 2301T-S uses a K=1 platinum-black cell and a temperature sensor. Current US documentation rates the probe to 200 mS/cm; the meter display ends at 199.9 mS/cm. K=0.1 and K=10 settings accommodate other suitable cells, not extra electrodes in this kit. Verify high-range work against an appropriate standard.

Know what this configuration supplies.

Included item Order contents
SX751 meter One handheld meter and one carrying case.
201T-S pH/temperature electrode One AI1312 electrode with storage vial.
2301T-S conductivity/temperature electrode One AI1313 K=1 cell with storage cap.
301Pt-S ORP electrode One AI1315 electrode with storage vial.
DO500 polarographic electrode One AI4110 electrode with calibration/storage sleeve and working membrane.
DO maintenance supplies Three spare DO503 membrane caps; one 30 mL DO502 refill; two cathode-polishing papers.
pH calibration buffers pH 4.00, 7.00 and 10.01; one 50 mL bottle each.
Conductivity standard 1413 µS/cm; one 50 mL bottle.
Batteries and tools Two AA cells listed as spare; screwdriver and user manual. No additional installed pair promised.
Actual SX751 carrying-case kit photograph. Use the itemized kit list for quantities; the battery requirement is two AA cells, not a promise of four supplied batteries.
Actual SX751 carrying-case kit photograph. Use the itemized kit list for quantities; the battery requirement is two AA cells, not a promise of four supplied batteries.
Original manufacturer numbered kit graphic. Live legend: 1 meter; 2 DO500; 3 pH probe; 4 ORP probe; 5 conductivity probe; 6 manual; 7 cathode polishing paper; 8 conductivity standard; 9 pH 10.01 buffer; 10 pH 4.00 buffer; 11 pH 7.00 buffer; 12 spare DO membranes; 13 DO refill; 14 two AA batteries; 15 screwdriver. The manual calls the two listed AA cells spare; installed-cell quantity is not independently confirmed.
Original manufacturer numbered kit graphic. Live legend: 1 meter; 2 DO500; 3 pH probe; 4 ORP probe; 5 conductivity probe; 6 manual; 7 cathode polishing paper; 8 conductivity standard; 9 pH 10.01 buffer; 10 pH 4.00 buffer; 11 pH 7.00 buffer; 12 spare DO membranes; 13 DO refill; 14 two AA batteries; 15 screwdriver. The manual calls the two listed AA cells spare; installed-cell quantity is not independently confirmed.

Match the sample and preparation method.

Routine water and treatment checks

Compare compatible water samples using consistent containers, immersion and temperature equilibration. Record the selected parameter and units with every result. Conductivity measures aggregate ionic response; calculated TDS is not a gravimetric solids test, and an ORP or pH reading alone cannot establish drinking-water safety.

Field rounds with deliberate sample records

The IP57-rated handheld format and carrying case suit spot-check routes where the operator can rinse probes between sites. Use the 400-set memory alongside a sample log. Protect the connector from contamination, keep spare solutions closed, and respect the stated 5 to 35°C instrument working environment.

Aquatic systems

For ponds, aquaculture or surface-water checks, allow time for DO polarization and sample flow. Do not treat a stationary oxygen probe as an unattended monitor. Use representative sampling and separately document pH and conductivity rather than implying all readings occurred at exactly the same instant.

Original pH calibration photograph with the supplied 201T-S electrode. Select the correct buffer series and wait for stability before accepting each point. Screen values are illustrative.
Original pH calibration photograph with the supplied 201T-S electrode. Select the correct buffer series and wait for stability before accepting each point. Screen values are illustrative.

Prepare each probe.
Calibrate each method separately.

Align the 8-pin plug notch with the single meter socket, push straight in and tighten only the metal locking ring. Do not twist the black rubber cable section. Rinse the selected electrode with distilled or deionized water before testing, remove excess water gently and avoid contaminating fresh standards.

For pH, use the selected USA, NIST or China buffer series and one to three recognized calibration points. The supplied bottles are pH 4.00, 7.00 and 10.01. The manual calls for three-point calibration with a new pH electrode. Match calibration and sample temperatures where practical; automatic temperature compensation corrects electrode response, not every chemical temperature effect.

For conductivity, calibrate in conductivity mode with one recognized standard close to the sample range. The kit supplies 1413 µS/cm, not every supported standard. Reference temperature choices are 18, 20 or 25°C; the linear coefficient adjusts from 0.00 to 9.99%/°C, default 2.00. Record settings before comparing batches.

For ORP, connect the 301Pt-S and wait for a stable mV value. The manual requires no ORP calibration; use a suitable 222 mV standard to check performance when needed, observing its temperature-dependent reference value. Do not apply the pH automatic-temperature-compensation claim to ORP or assume a clean pH electrode validates this separate probe.

For DO500, polarize for five minutes after power-on before calibration or testing. Use 30 minutes after replacing a membrane cap or inner solution. Calibrate at saturation in the sleeve with a moist, non-dripping sponge and wait for stability. Temperature and salinity compensation are automatic; barometric pressure is entered manually.

Routine DO calibration is saturation calibration. Optional zero-oxygen calibration follows the exact model manual and requires separately obtained supplies. Sodium sulfite and the 12.88 mS/cm standard for salinity-sensor recalibration are not listed kit supplies. DO502 is electrode electrolyte, not a calibration standard.

Original conductivity calibration photograph with the 2301T-S cell. Calibrate in conductivity mode using a suitable recognized standard. The pictured display is an example, not a certified result.
Original conductivity calibration photograph with the 2301T-S cell. Calibrate in conductivity mode using a suitable recognized standard. The pictured display is an example, not a certified result.
Original DO calibration photograph: the DO500 sits in its calibration sleeve, which maintains water-saturated air with a moist sponge. Polarize first and allow stabilization. The screen is an example, not a recorded sample result.
Original DO calibration photograph: the DO500 sits in its calibration sleeve, which maintains water-saturated air with a moist sponge. Polarize first and allow stabilization. The screen is an example, not a recorded sample result.

Understand the sensing end and connections.

Original SX751 ORP and DO configuration graphic. These are alternative single-probe connections, not two simultaneous channels. Display values are examples.
Original SX751 ORP and DO configuration graphic. These are alternative single-probe connections, not two simultaneous channels. Display values are examples.
201T-S pH/temperature electrode, AI1312, shown with its 8-pin connector and storage vial. Store in 3M KCl rather than pure water.
201T-S pH/temperature electrode, AI1312, shown with its 8-pin connector and storage vial. Store in 3M KCl rather than pure water.
2301T-S conductivity/temperature electrode, AI1313, K=1, with an 8-pin connector. Its storage cap uses clean distilled or deionized water, not pH storage solution.
2301T-S conductivity/temperature electrode, AI1313, K=1, with an 8-pin connector. Its storage cap uses clean distilled or deionized water, not pH storage solution.
DO500 polarographic electrode, AI4110, shown with its calibration sleeve and replacement membrane caps. This is a membrane/electrolyte probe, not an optical DO803 sensor.
DO500 polarographic electrode, AI4110, shown with its calibration sleeve and replacement membrane caps. This is a membrane/electrolyte probe, not an optical DO803 sensor.
301Pt-S ORP electrode, AI1315. The original photograph shows the 8-pin plug and storage vial. The included ORP probe is separate from the pH electrode.
301Pt-S ORP electrode, AI1315. The original photograph shows the 8-pin plug and storage vial. The included ORP probe is separate from the pH electrode.

Different probes need
different storage and maintenance.

Keep the 201T-S glass bulb hydrated in its 3M KCl storage solution. Do not store a pH electrode in distilled or deionized water. By contrast, the 2301T-S conductivity cap uses clean distilled or deionized water. Rinse between samples and keep the electrical plug dry; never interchange these storage routines.

The low-conductivity nonlinear compensation function is described for readings below 10 µS/cm. It does not make the supplied pH electrode suitable for ultrapure water. For very low ionic strength pH samples, select an appropriate specialist electrode. Low-range conductivity may require a compatible K=0.1 cell and a controlled flow-cell method.

DO500 consumes oxygen during measurement. In still water, the manual requires continuous slow swirling above 5 cm/s, including while recording. Keep the temperature sensor submerged and the probe at 45 to 75 degrees to the surface. Inspect the membrane and electrolyte for damage or bubbles; use DO503 caps and DO502 refill rather than treating it as a no-refill optical probe.

The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.

DO500 is intended for general water solutions, not strong acidic, strong alkaline or organic solutions. Its probe operating temperature is 0 to 50°C, distinct from DO compensation at 0 to 45°C and meter operating conditions.

DO503 replacement membrane caps, AI4113, shown as a three-piece service pack. The kit lists three spare caps, in addition to the working cap on the DO500. Avoid touching the sensitive membrane.
DO503 replacement membrane caps, AI4113, shown as a three-piece service pack. The kit lists three spare caps, in addition to the working cap on the DO500. Avoid touching the sensitive membrane.
DO502 inner solution, AI4112: one 30 mL refill bottle is listed in the kit. Refill without trapped bubbles, then allow 30 minutes of polarization after replacing solution or membrane.
DO502 inner solution, AI4112: one 30 mL refill bottle is listed in the kit. Refill without trapped bubbles, then allow 30 minutes of polarization after replacing solution or membrane.
Original 301Pt-S sensing-end close-up from its exact probe page. The protected platinum sensing surface is shown without the storage vial; inspect and clean this electrode separately from the pH probe. No pixels or labels have been invented.
Original 301Pt-S sensing-end close-up from its exact probe page. The protected platinum sensing surface is shown without the storage vial; inspect and clean this electrode separately from the pH probe. No pixels or labels have been invented.
Original DO500 annotated component photograph, not a sample reading. Live legend: integrated salinity sensor; temperature sensor; silver anode; gold cathode; replaceable membrane cap. Keep the membrane sound, refill electrolyte when needed and polarize after service.
Original DO500 annotated component photograph, not a sample reading. Live legend: integrated salinity sensor; temperature sensor; silver anode; gold cathode; replaceable membrane cap. Keep the membrane sound, refill electrolyte when needed and polarize after service.
Original DO500 maintenance schematic. Legend: 1 probe; 2 sleeve cap; 3 sleeve; 4 moist sponge; 5 sleeve bottom lid; 6 temperature sensor; 7 replaceable membrane cap; 8 gold cathode; 9 silver anode; 10 salinity sensor. This is not an optical sensor.
Original DO500 maintenance schematic. Legend: 1 probe; 2 sleeve cap; 3 sleeve; 4 moist sponge; 5 sleeve bottom lid; 6 temperature sensor; 7 replaceable membrane cap; 8 gold cathode; 9 silver anode; 10 salinity sensor. This is not an optical sensor.
Original manual connection schematic. Align the notch, push the 8-pin plug straight into the single input, then tighten the metal ring. Never twist the black rubber cable section. Disconnect before changing probes.
Original manual connection schematic. Align the notch, push the 8-pin plug straight into the single input, then tighten the metal ring. Never twist the black rubber cable section. Disconnect before changing probes.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Save the readings you choose.
Keep sample identity in your own log.

The exact SX751 manual documents 400 stored sets. A short memory-key press saves a stabilized result; a long press enters recall. Records contain a serial number, measurement value, unit and temperature. The stated capacity is not a promise of 400 records for every mode or simultaneous complete-parameter datasets.

M+ and RM identify saving and recall. The manual does not document a date/time clock, timed-interval storage, USB export, Bluetooth, browser export or an electronic GLP audit trail. Record sample identity and collection time separately. Deleting memory clears all saved records, so transcribe the required values before using that command.

Original manual LCD schematic, not a real reading and not simultaneous parameters. Legend: 1 parameter; 2 result; 3 record number and M+/RM store/recall status; 4 units; 5 temperature; 6 stability; 7 calibration indicators; 8 low battery. No clock is shown.
Original manual LCD schematic, not a real reading and not simultaneous parameters. Legend: 1 parameter; 2 result; 3 record number and M+/RM store/recall status; 4 units; 5 temperature; 6 stability; 7 calibration indicators; 8 low battery. No clock is shown.

Compare another measurement format.

Related workflow: Apera DO8500 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI485. The linked optical DO kit has a different sensor technology and maintenance workflow; its probe or cap is not interchangeable with DO500. It is a DO-workflow option, not a replacement for this kit’s other parameters. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

SX751 buyer questions

What exactly is included with SX751 / AI469?

The supplied electrode models are 201T-S, 301Pt-S, 2301T-S and DO500. All connect through the single 8-pin input. DO500 is polarographic, with replaceable membrane and electrolyte. SX751 includes the separate 301Pt-S for ORP.

Can it measure every parameter at once?

No. Change the connected electrode for a different measurement family. Recognition selects that probe’s mode; conductivity-derived TDS, salinity and resistivity are display choices, not extra independent sensors. Temperature can accompany supported measurements.

What are the replacement probe part numbers?

201T-S is AI1312; 2301T-S is AI1313; 301Pt-S is AI1315; DO500 is AI4110. DO502 refill is AI4112 and DO503 membrane caps are AI4113. Choose the S-version 8-pin connection, not a T-F BNC/RCA substitute. The optional AI7103 adapter is not supplied.

Does the complete kit cover the full displayed pH and EC ranges?

Not without considering electrode limits and sample chemistry. The current 201T-S page narrows its range to 0 to 13 pH and 0 to 60°C; older manuals differ. The 2301T-S is rated 0.5 µS/cm to 200 mS/cm. Optional cell constants and low-ion compensation do not remove sample-specific limitations. The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.

How much memory is available, and can I export it?

The exact manual and specification table state 400 sets, saved and recalled manually, with result, units, temperature and serial number. No timed logging, clock timestamps or electronic export is documented.

Is the DO probe optical or maintenance-free?

No. DO500 is polarographic. It needs polarization, sound membranes, electrolyte and water movement. It automatically compensates temperature and salinity, but pressure compensation is manual. A 30-second 90% response specification at 25°C is not a guarantee of a finished field result in 30 seconds.

How many solution bottles, spare caps and batteries are supplied?

Three 50 mL pH buffers and one 50 mL 1413 µS/cm conductivity standard are listed. The DO kits also list three spare DO503 caps, one 30 mL DO502 refill and two cathode-polishing papers. The manual lists two spare AA cells; it does not independently establish an additional installed pair, so four batteries are not promised.

What warranty applies to the instrument, probes and consumables?

The current US product page and exact model manual specify three years for the instrument and six months for electrodes, both from delivery. Coverage concerns defects attributable to Apera, with repair or replacement at its option. Exclusions include normal wear, improper use, transport/storage damage, failure to follow instructions or preventive maintenance, unauthorized changes or repair, and external causes. No separate extended warranty term for membranes or refill solution is stated; routine consumable replacement is not promised.

Confirm the exact configuration before ordering.

Review SX751 AI469 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / SKUSX751 / AI469
    Supplied measurement familiespH, ORP, conductivity and dissolved oxygen
    Electrode inputOne 8-pin socket; sequential probe changes
    pH meter range / resolution-2.00 to 19.99 pH / 0.01 or 0.1 pH
    pH accuracy, manualMeter ±0.01 pH; overall ±0.02 pH
    pH temperature compensationAutomatic, 0 to 100°C meter range; observe narrower probe limits
    201T-S current US probe limits0 to 13 pH; 0 to 60°C; general aqueous samples The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.
    EC ranges0.00-19.99, 20.0-199.9, 200-1999 µS/cm; 2.00-19.99, 20.0-199.9 mS/cm
    EC accuracy, manualMeter ±1.0% F.S.; overall ±1.5% F.S.
    Derived displaysTDS 0-100 g/L; salinity 0-100 ppt; resistivity 0-100 MΩ·cm
    EC temperature compensationAutomatic 0-50°C; reference 18/20/25°C
    EC constants / calibrationK=0.1, 1, 10; supplied K=1; one-point recognized calibration
    ORP range / resolution-1999 to +1999 mV / 1 mV
    ORP accuracy, manualMeter ±0.1% F.S.; overall ±15 mV
    DO range / resolution0-19.99 mg/L (ppm), 0-200.0%; 0.01/0.1 mg/L, 0.1/1%
    DO accuracy / type±0.30 mg/L including electrode error; polarographic
    DO compensationTemperature 0-45°C automatic; salinity 0-45 ppt automatic; pressure 66-200 kPa manual
    DO response / polarization90% response ≤30 s at 25°C; 5 min routine, 30 min after membrane/electrolyte service
    Internal memory400 sets; manual save/recall; no documented timestamps or export
    PowerTwo 1.5 V AA alkaline batteries
    Meter size / weight65 × 120 × 31 mm / 180 g
    Environment / protection5-35°C; ≤85% RH; IP57
    US limited warrantyInstrument 3 years; electrodes 6 months from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI469
    Blue Tiger SKUBTS-AI469
    Order unit1 exact listed meter-kit configuration
    Order contentsSX751 meter: One handheld meter and one carrying case.; 201T-S pH/temperature electrode: One AI1312 electrode with storage vial.; 2301T-S conductivity/temperature electrode: One AI1313 K=1 cell with storage cap.; 301Pt-S ORP electrode: One AI1315 electrode with storage vial.; DO500 polarographic electrode: One AI4110 electrode with calibration/storage sleeve and working membrane.; DO maintenance supplies: Three spare DO503 membrane caps; one 30 mL DO502 refill; two cathode-polishing papers.; pH calibration buffers: pH 4.00, 7.00 and 10.01; one 50 mL bottle each.; Conductivity standard: 1413 µS/cm; one 50 mL bottle.; Batteries and tools: Two AA cells listed as spare; screwdriver and user manual. No additional installed pair promised.

    Apera Manufacturer Limited Warranty

    The current US product page and exact model manual specify three years for the instrument and six months for electrodes, both from delivery. Coverage concerns defects attributable to Apera, with repair or replacement at its option. Exclusions include normal wear, improper use, transport/storage damage, failure to follow instructions or preventive maintenance, unauthorized changes or repair, and external causes. No separate extended warranty term for membranes or refill solution is stated; routine consumable replacement is not promised.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat