Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Default Title Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Default Title Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments
Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes Portable Multiparameter Meter Apera Instruments

Apera SX723 Portable pH/Conductivity Meter Kit with 201T-S and 2301T-S Electrodes

$399.00

    Separate pH and conductivity probes, focused calibration routines and local manual memory.

    • 201T-S pH/temperature and 2301T-S K=1 conductivity/temperature probes
    • One- to three-point pH calibration; one-point conductivity calibration
    • EC, calculated TDS, salinity and resistivity selected sequentially
    • Current page: 300 stored sets; older manual says 400

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / SX723 / AI477

pH plus conductivity-derived readings.
One portable meter, two purpose-built probes.

SX723 provides pH, conductivity, calculated TDS, salinity, resistivity and temperature for compatible water-solution work. The kit supplies a 201T-S pH/temperature electrode and a 2301T-S conductivity/temperature electrode, each with an 8-pin plug. Change electrodes for the measurement family, then select the conductivity-derived parameter on the meter.

Choose AI477 when you need acidity and ionic-conductivity information during the same field visit without carrying two meters. This is not simultaneous pH and conductivity measurement. The supplied conductivity cell is the 2301T-S, not the BNC/RCA 2301T-F, and no ORP or dissolved-oxygen electrode is included.

SX723 connected to 201T-S pH electrode, cropped from exact manufacturer mode panel
Exact SX723 pH configuration cropped from the original manufacturer mode illustration without changing hardware or labels. The 2301T-S conductivity probe is also supplied and connects separately.
Which meter kit fits my measurement?Click or tap to compare all eight measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, ORP, conductivity and polarographic dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Apera SX711

SX711

AI460

pH and temperature

201T-S pH/temperature probe; ORP electrode separate.

View SX711 →
Apera SX721

SX721

AI463

pH and ORP kit

Separate pH and ORP probes; one connection at a time.

View SX721 →
Apera SX723

SX723

AI477

pH and conductivity kit

Separate 201T-S and 2301T-S probes; sequential tests.

Current item
Apera SX716

SX716

AI461

Polarographic dissolved oxygen

DO500 membrane probe; polarization and movement required.

View SX716 →
Apera SX725

SX725

AI465

pH and dissolved oxygen

Swap the pH and DO500 probes for sequential tests.

View SX725 →
Apera SX731

SX731

AI467

pH, ORP and conductivity

Three supplied sensor types; not simultaneous acquisition.

View SX731 →
Apera SX736

SX736

AI468

pH, conductivity and DO

Three probe workflows with distinct storage and calibration.

View SX736 →
Apera SX751

SX751

AI469

pH, ORP, conductivity and DO

Four probe workflows; one input and model-specific records.

View SX751 →

Choose the electrode for the sample.

Switch probes, then select the parameter

Automatic electrode recognition changes the meter to pH when the 201T-S is connected and to conductivity when the 2301T-S is connected. In conductivity mode, hold the confirmation/backlight key to cycle through TDS, salinity, resistivity and conductivity, releasing it at the desired parameter. These are selected views, not four independently connected sensors or a simultaneous multi-parameter display.

A platinum-black conductivity cell with its own thermistor

The supplied 2301T-S has a POM body, K=1 cell constant and built-in 30 kΩ temperature sensor. Its locking 8-pin plug differs from the 2301T-F’s BNC/RCA arrangement. The conductivity range reaches the 200 mS/cm class, but the current specification table ends at 199.9 mS/cm. Confirm a different cell constant and exact probe compatibility before planning very-low-conductivity work.

Keep calculated readings tied to a method

TDS, salinity and resistivity are derived from the conductivity response rather than independent chemical assays. Reference temperature is selectable at 18, 20 or 25°C; the compensation coefficient adjusts from 0.00 to 9.99%/°C. Document these settings when comparing results. The exact SX723 manual does not document a user-adjustable TDS conversion-factor menu, so one is not promised here.

Know what this configuration supplies.

Included item Order contents
SX723 handheld meter AI477 pH/conductivity configuration with silicone boot listed in the exact manual.
201T-S pH/temperature electrode AI1312, supplied 8-pin combination electrode with storage bottle; not a BNC 211 electrode.
2301T-S conductivity/temperature electrode AI1313, K=1 platinum-black cell in POM body; locking 8-pin connector and storage cap.
Three pH buffers pH 4.00, 7.00 and 10.01, one 50 mL bottle each. Recognition of additional values does not add bottles.
1413 µS/cm conductivity standard One 50 mL bottle; additional conductivity standard values are not included.
Field accessories Carrying case, mini screwdriver and user manual.
Backup AA batteries Two spare alkaline AA batteries are listed. The meter runs on two AA cells; no four-battery total is promised.
SX723 kit illustration with reversed pH-buffer references 4 and 5; read the bottle labels and live correction
Important artwork correction: the manufacturer illustration reverses pH-buffer references 4 and 5. Identify each buffer by its bottle label, not those printed references. The kit includes pH 4.00, 7.00 and 10.01 buffers, 50 mL each, plus the separately listed conductivity standard. See the itemized kit table for the verified contents.

Match the sample and preparation method.

Nutrient-solution and general water checks

Measure pH and conductivity as complementary observations in compatible hydroponic or water-treatment samples. Rinse and switch probes between measurements. Conductivity responds to the combined ionic content, while pH describes acidity; neither independently identifies which nutrient or dissolved substance is present.

Process rinses and field comparisons

Use consistent vessels, immersion, mixing and temperature settings when comparing rinse stages or locations. For conductivity, brief stirring helps dislodge trapped bubbles at the cell. Keep a worksheet that links each separate pH and conductivity record to the same sample rather than assuming the meter saves them as a synchronized pair.

Know the limit of pure-water claims

The meter has low-conductivity compensation functions, but that does not make the stock pH electrode suitable for low-ionic-strength water. The 201T-S guide specifically warns about distilled or deionized-water pH testing. For demanding pure-water work, establish the correct specialist probe, cell constant, sampling arrangement and method before purchase.

SX723 conductivity calibration photograph
Original conductivity-calibration view. SX723 uses one-point conductivity calibration; the supplied standard is 1413 µS/cm. The illustrative screen is not a certified standard value.

Two measurement families.
Two different calibration routines.

Connect the 201T-S with the notch aligned to the meter socket. Push straight in while holding the metal ring, then tighten that ring. Do not rotate the black rubber cable sleeve. Remove the storage bottle without spilling its KCl, rinse the tip with distilled or deionized water, and gently remove excess rinse water without rubbing the glass membrane.

For the supplied USA buffers, begin with pH 7.00. Press CAL, immerse the electrode, stir briefly and hold it still. Wait until the stability symbol stays on, then confirm as directed by the manual. Rinse between solutions and continue with pH 4.00 and pH 10.01 for three-point calibration. Use fresh, separate portions and never return used buffer to the original bottle.

The meter supports one, two or three calibration points. Select buffers that bracket the expected samples; a new pH electrode requires three-point calibration. The USA set lists 1.68, 4.00, 7.00, 10.01 and 12.45; NIST lists 1.68, 4.01, 6.86, 9.18 and 12.45. A China series is also selectable. The current page’s “13 kinds” wording describes recognition, not thirteen calibration points or thirteen included bottles. Match the selected series to the actual bottle labels.

For conductivity, connect the 2301T-S, confirm K=1 and return to conductivity mode before pressing CAL. Rinse the cell, immerse it in the supplied 1413 µS/cm standard, stir briefly to release bubbles and wait for stability before confirming. SX723 uses one-point conductivity calibration. The probe’s general PDF suggests multi-point calibration for other instruments; that generic instruction does not add multi-point capability to SX723.

The exact meter manual lists USA conductivity standards of 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.9 mS/cm; its China series lists 146.6 µS/cm, 1408 µS/cm, 12.85 mS/cm and 111.3 mS/cm. Eight recognized standards across two series do not mean eight calibration points. Only one 50 mL bottle of 1413 µS/cm is listed in this kit. Choose a suitable standard for the sample range.

SX723 pH calibration photograph
Use the 201T-S for pH and select the matching buffer series. One to three pH points are supported; this is separate from one-point conductivity calibration.

Understand the sensing end and connections.

2301T-S conductivity-cell and temperature-sensor annotated close-up
Original manufacturer sensor legend: conductivity cell and temperature sensor. The supplied K=1 2301T-S uses an 8-pin connector; it is not the 2301T-F BNC/RCA version.
201T-S pH sensing-tip manufacturer image
Original 201T-S sensing-tip photograph. Fast response, Accuracy and Stable describe design intent, not guaranteed performance in every sample. The current probe-page limits and sample restrictions still apply.
201T-S electrode with storage bottle and locking 8-pin plug
Supplied 201T-S, AI1312: the storage bottle hydrates the pH tip with 3M KCl. Native connection is 8-pin, not BNC. White padding preserves the original portrait without stretching.

Different sensors need different storage.
KCl for pH, clean water for conductivity.

Rinse the 201T-S before and after each measurement, then return it to its cap with enough Apera 3M KCl storage solution to cover the sensing tip. Pure water is appropriate for rinsing, not for storing this pH electrode. Keep the bottle upright and renew contaminated storage solution. The gel reference electrolyte is not user-refillable.

The current 201T-S page specifies 0 to 13 pH and 0 to 60°C, while its PDF specifies 0 to 14 pH and 0 to 80°C. Treat the narrower current-page limits as the buying guide and confirm demanding applications before ordering. The PDF additionally cautions against prolonged use above 50°C, frequent strong acid or alkali measurements, low-ionic-strength water and liquids that attack the polycarbonate housing. A wide meter display does not remove those probe limitations.

Clean according to the exact electrode guide, using a treatment suitable for the contamination rather than abrasive scrubbing. Rehydrate and recalibrate after cleaning. Keep plugs dry, clean and protected when disconnected. The IP57 rating is an enclosure protection specification, not a promise that an exposed connector or glass sensing bulb can tolerate immersion, drops, solvents or unrestricted chemical exposure.

Store the 2301T-S conductivity sensor in its cap filled with clean distilled or deionized water, replacing contaminated water. Do not use the pH electrode’s KCl storage solution in this cap. Rinse before and after use, avoid rubbing the platinum-black cell and follow the probe guide for residue-specific cleaning. Conductivity ATC covers 0 to 50°C; the probe guide separately lists a wider operating-temperature limit. That wider limit does not extend the compensated measurement range.

2301T-S with locking 8-pin connector and storage cap
Supplied 2301T-S, AI1313. Store this conductivity cell in a cap of clean distilled or deionized water, not the pH probe’s KCl storage solution.
Original 8-pin electrode disconnection instructions
Disconnection steps: loosen the metal ring to unlock, then hold that ring and pull straight out. Do not twist the black rubber sleeve; protect the unplugged connector from water and dirt.
Manufacturer panel comparing pH and conductivity electrode configurations
Two alternative configurations of the same SX723, not two supplied meters and not simultaneous measurement. Left: 201T-S pH/temperature. Right: 2301T-S conductivity/temperature.
Original 8-pin electrode connection instructions
Connection steps: align the notch, push straight in while holding the metal ring, then tighten the metal ring. Never twist the black rubber sleeve. The diagram shows one meter input.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Current-page memory: 300 sets.
Manual storage is not a timed logger.

The current SX723 page specifies 300 stored sets. Its exact v3.0 PDF specifies 400 in both the technical table and save-data instructions, while a current gallery memory illustration says 200. This listing follows the current 300-set product specification and explicitly discloses the conflicting legacy sources. Confirm unit-specific capacity if the size of a field round depends on it.

The documented workflow is a short press to save a stable measurement and a long press to recall saved readings. Records contain serial number, value, unit and temperature. The exact manual does not document scheduled intervals, real-time-clock timestamps, USB transfer, computer software or a phone app. The backlight and power-off timers are not data-logging settings.

Keep sample name, collection time, connected probe and compensation settings in a separate worksheet, then transcribe required readings before clearing memory. A TDS record and a pH record are separate observations, even when taken from the same vessel. On-meter recall does not provide an audit trail or establish any regulatory or laboratory accreditation claim.

SX723 exact-manual LCD and numbered status symbols
Original exact-manual LCD legend: 1 parameter; 2 value; 3 save/recall number; 4 unit; 5 temperature; 6 stability; 7 calibration ranges; 8 low battery. M+ is save and RM is recall; neither is a clock. This manual uses a family segment diagram: DO and other unused segments do not add capabilities to SX723. Refer to the listed measurement modes, not every printed segment.

Compare another measurement format.

Alternative format: Apera PC8500 Portable pH and Conductivity Meter Kit with USB Data Logging. The linked meter uses a different measurement format, supplied probe set or record workflow; compare its exact kit rather than assuming probe interchangeability. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

SX723 buyer questions

Which probes are supplied?

201T-S pH/temperature, AI1312, and 2301T-S conductivity/temperature, AI1313, both 8-pin. The similarly named 2301T-F uses different connectors and is not the supplied cell.

Does automatic recognition mean simultaneous pH and EC?

No. The exact manual shows one input and tells the operator to connect the relevant electrode. Conductivity, TDS, salinity and resistivity are then selected one at a time with the key control.

How many conductivity calibration points are supported?

One. The current page and exact SX723 manual specify one-point calibration, with eight recognized values across USA and China series. The supplied standard is 1413 µS/cm, 50 mL. The generic probe guide does not override this meter-specific method.

Is memory 200, 300 or 400 sets?

The current SX723 product page says 300. The v3.0 manual says 400, and an older gallery panel says 200. We use the current 300-set specification and retain this discrepancy rather than silently combining sources.

Can I export records or set timed logging?

No USB export, clock stamps, app connection or interval recording is documented for SX723. Saving and recall are manual; preserve timestamps, identifiers and settings in your own worksheet.

Can the supplied pH probe test ultrapure water or the full meter range?

Not as a general promise. The stock 201T-S is for general water solutions and warns against low-ionic-strength samples. Its current page specifies narrower pH and temperature limits than both the meter and the probe PDF.

Are ORP, DO or BNC adapters included?

No ORP or DO electrode and no BNC converter are listed in AI477. The current page allows compatible LabSen pH alternatives through a separately sold 8-pin converter, but each exact configuration needs verification.

What warranty applies to SX723?

The current US SX723 page and its exact v3.0 manual specify 36 months for the instrument and six months for the electrode from delivery. The limited warranty covers qualifying defects attributable to Apera. Exclusions include accidental damage, normal wear, improper use or storage, transport damage, failure to follow instructions, unauthorized repair or modification, and other stated external causes. This is not a probe-life guarantee.

Confirm the exact configuration before ordering.

Review SX723 AI477 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / SKUSX723 / AI477
    Measured and derived parameterspH, conductivity, calculated TDS, salinity, resistivity and temperature; sequential workflow
    pH electronics range-2.00 to 19.99 pH
    pH resolution0.1 or 0.01 pH
    pH accuracy basisManual: meter ±0.01 pH; overall ±0.02 pH. Current page: ±0.01 pH ±1 digit.
    Supplied pH electrode201T-S, AI1312; 8-pin; single fiber ceramic junction; Ag/AgCl reference; gel KCl
    Supplied pH probe limitsCurrent probe page: 0 to 13 pH, 0 to 60°C; PDF lists wider limits. Prolonged high-temperature use is restricted.
    pH calibration1 to 3 points; selectable USA, NIST and China recognition series
    pH temperature compensationAutomatic, meter specification 0 to 100°C; supplied-probe limits are separate
    Conductivity range0.00 to 199.9 mS/cm across five automatic ranges; marketed as 0 to 200 mS/cm
    Conductivity resolution0.01 / 0.1 / 1 µS/cm; 0.01 / 0.1 mS/cm
    Conductivity accuracy basisCurrent page ±1.0% FS; manual meter ±1.0% FS, overall ±1.5% FS
    TDS / salinity / resistivity ranges0 to 100 g/L / 0 to 100 ppt / 0 to 100 MΩ·cm
    Supplied conductivity cell2301T-S, AI1313; K=1; POM; platinum-black cell; 8-pin; 30 kΩ thermistor
    Conductivity calibration1 point; USA or China recognized-standard series
    Conductivity ATC / reference0 to 50°C / selectable 18, 20 or 25°C
    Cell constant selection0.1 / 1 / 10 cm⁻¹; supplied cell K=1
    Compensation coefficient0.00 to 9.99%/°C
    Current memory capacity300 sets on current page; manual 400 and old gallery graphic 200 conflict
    Memory record fieldsSerial number, measurement value, unit and temperature; no documented clock/date field
    Timed logging / exportNo documented interval logging, USB export, Bluetooth or app connection
    PowerTwo 1.5 V AA alkaline batteries; kit lists two backup/spare AA batteries
    Meter size / mass65 × 120 × 31 mm / 180 g; not shipping weight
    ProtectionIP57; keep connectors clean and dry
    Limited warranty36 months instrument, 6 months electrode, from delivery; exclusions apply
    Operating environment5 to 50°C; relative humidity ≤85%

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI477
    Blue Tiger SKUBTS-AI477
    Order unit1 exact listed meter-kit configuration
    Order contentsSX723 handheld meter: AI477 pH/conductivity configuration with silicone boot listed in the exact manual.; 201T-S pH/temperature electrode: AI1312, supplied 8-pin combination electrode with storage bottle; not a BNC 211 electrode.; 2301T-S conductivity/temperature electrode: AI1313, K=1 platinum-black cell in POM body; locking 8-pin connector and storage cap.; Three pH buffers: pH 4.00, 7.00 and 10.01, one 50 mL bottle each. Recognition of additional values does not add bottles.; 1413 µS/cm conductivity standard: One 50 mL bottle; additional conductivity standard values are not included.; Field accessories: Carrying case, mini screwdriver and user manual.; Backup AA batteries: Two spare alkaline AA batteries are listed. The meter runs on two AA cells; no four-battery total is promised.

    Apera Manufacturer Limited Warranty

    The current US SX723 page and its exact v3.0 manual specify 36 months for the instrument and six months for the electrode from delivery. The limited warranty covers qualifying defects attributable to Apera. Exclusions include accidental damage, normal wear, improper use or storage, transport damage, failure to follow instructions, unauthorized repair or modification, and other stated external causes. This is not a probe-life guarantee.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat