Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Default Title Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX716 Portable Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Polarographic Dissolved Oxygen Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Default Title Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Multiparameter Meter Apera Instruments
Apera SX716 Portable Dissolved Oxygen Meter Kit with DO500 Polarographic Probe Portable Polarographic Dissolved Oxygen Meter Apera Instruments

Apera SX725 Portable pH and Dissolved Oxygen Meter Kit with DO500 Polarographic Probe

$595.00

    Polarographic DO, automatic temperature and salinity compensation, and 300 manually saved records.

    • DO500 and 201T-S electrodes; sequential 8-pin connection
    • One- to three-point pH calibration with three included buffers
    • 300 stored sets with on-meter recall
    • Three spare membrane caps and 30 mL electrolyte included

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / SX725 / AI465

Two water checks.
One probe connection at a time.

SX725 pairs a DO500 polarographic oxygen probe with a 201T-S pH/temperature electrode for sequential testing of general water solutions. Change electrodes to change measurement tasks. Its backlit screen, 300-set memory and fitted carrying case support a practical field workflow.

Choose AI465 when you need pH and DO in one case, not simultaneous multi-channel monitoring. The 8-pin input recognizes the connected electrode; temperature accompanies the selected measurement. The included probes are for general aqueous samples, not every liquid the meter can display a number for.

SX725 meter connected to its DO500 probe
SX725 shown in its DO configuration. Disconnect this electrode before connecting the 201T-S for pH; this is not concurrent pH/DO measurement.
Which meter kit fits my measurement?Click or tap to compare all eight measurement configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH, ORP, conductivity and polarographic dissolved oxygen are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Apera SX711

SX711

AI460

pH and temperature

201T-S pH/temperature probe; ORP electrode separate.

View SX711 →
Apera SX721

SX721

AI463

pH and ORP kit

Separate pH and ORP probes; one connection at a time.

View SX721 →
Apera SX723

SX723

AI477

pH and conductivity kit

Separate 201T-S and 2301T-S probes; sequential tests.

View SX723 →
Apera SX716

SX716

AI461

Polarographic dissolved oxygen

DO500 membrane probe; polarization and movement required.

View SX716 →
Apera SX725

SX725

AI465

pH and dissolved oxygen

Swap the pH and DO500 probes for sequential tests.

Current item
Apera SX731

SX731

AI467

pH, ORP and conductivity

Three supplied sensor types; not simultaneous acquisition.

View SX731 →
Apera SX736

SX736

AI468

pH, conductivity and DO

Three probe workflows with distinct storage and calibration.

View SX736 →
Apera SX751

SX751

AI469

pH, ORP, conductivity and DO

Four probe workflows; one input and model-specific records.

View SX751 →

Choose the electrode for the sample.

Compensate for the water you are testing

DO500 contains temperature and salinity sensors. DO compensation is automatic over 0 to 45°C and 0 to 45 ppt; barometric pressure is entered manually over 66 to 200 kPa. The P3 example of 101.3 means kPa, not mbar. These corrections do not remove the need for calibration, clean sensors or adequate water movement.

Recognize the electrode, then select the task

Connect the 201T-S for pH and temperature or the DO500 for dissolved oxygen and temperature. Automatic electrode recognition is not simultaneous pH/DO acquisition. The manual also specifies an mV mode, but an ORP electrode and any required connection accessory are not included.

Replace the membrane, not the whole workflow

The DO503 cap holds a sensitive membrane over the gold cathode and silver anode. DO502 inner solution completes the serviceable assembly. Keep spare caps clean and avoid touching their membrane faces. The kit includes the maintenance materials and a screwdriver; replacement frequency depends on condition, not a promised fixed service interval.

Know what this configuration supplies.

Included item Order contents
SX725 meter One handheld instrument.
DO500 polarographic DO electrode One 8-pin probe with temperature/salinity sensors and calibration/storage sleeve.
201T-S pH/temperature electrode One 8-pin combination electrode with KCl storage bottle.
pH calibration buffers pH 4.00, 7.00 and 10.01; one 50 mL bottle each.
DO502 inner solution One 30 mL bottle of DO electrolyte.
DO503 membrane caps Three spare caps.
DO504 polishing paper Two pieces for the gold cathode.
Service and transport items One screwdriver, two spare AA batteries, operation manual and carrying case.
Numbered SX725 carrying-case contents
Kit legend: 1 SX725; 2 201T-S; 3 DO500; 4 pH 7.00 buffer; 5 pH 10.01 buffer; 6 pH 4.00 buffer; 7 three spare DO503 caps; 8 two polishing-paper pieces; 9 DO502, 30 mL; 10 two AA batteries; 11 screwdriver; 12 manual. Each buffer is 50 mL.
Open SX725 case with both electrodes and accessories
Separate compartments hold the two electrodes, three pH buffers, electrolyte, spare caps and service tools.

Match the sample and preparation method.

Aquaculture and surface-water rounds

Compare oxygen conditions in compatible pond, aquarium or surface-water samples. Let the probe approach sample temperature and maintain flow across the membrane. Record location and collection time separately so readings remain meaningful after on-meter recall.

Water-treatment pH and oxygen checks

Use the two electrodes in separate measurement steps. Rinse between solutions and calibrate each method independently. Conductivity, TDS and resistivity are not included measurement channels; the DO salinity sensor provides oxygen compensation.

Training with visible maintenance steps

The replaceable membrane, sleeve and original electrode figures make preparation and care easy to explain. A field reading does not establish potability, regulatory compliance or biological safety. Strong acidic or alkaline water and organic solutions are outside DO500’s listed suitable samples.

Original SX725 saturated-oxygen calibration illustration
Use the moist-sponge sleeve for routine 100% calibration. After polarization, allow three to five minutes or longer until stable before confirming. The pictured reading is an illustration, not the target value to enter manually.

Polarize first.
Calibrate, then keep the water moving.

Connect DO500 to the powered meter and allow five minutes of polarization after every power-on. After changing the membrane cap or electrolyte, allow 30 minutes instead. The response specification is no more than 30 seconds to 90% response at 25°C, not a guarantee of a fully stable result in 30 seconds.

For routine 100% calibration, moisten the sleeve sponge with several drops of distilled water without making it drip. Insert the probe, tighten the sleeve cap and enter CAL. Allow three to five minutes, longer if unstable, then confirm only after stabilization. Keep calibration and sample temperatures within 10°C; for a larger difference, precondition the probe in sample water for about ten minutes.

Immerse above the temperature sensor and hold the probe at 45° to 75° to the water surface. In flowing water, wait for stability and swirl slowly if needed. In static water, keep swirling faster than 5 cm/s for one to five minutes and continue while recording. A large temperature difference requires more than three minutes. Stopping motion lets the electrode deplete nearby oxygen.

The specification also lists air-saturated water, but the detailed routine procedure uses water-saturated air in the sleeve. Optional zero calibration is intended for demanding work below 1.0 ppm. Follow the manual’s fresh sodium-sulfite solution, 15-minute polarization and acceptance checks. Arbitrary custom DO calibration points are not documented. Salinity is factory-calibrated; after electrode replacement, the P2 procedure uses separately purchased 12.88 mS/cm standard.

For pH, rinse the 201T-S, briefly stir in buffer, then hold still until stable. Use one, two or three points from the selected USA, NIST or China series; the kit supplies pH 4.00, 7.00 and 10.01. Calibrate a new pH electrode at all three points. Do not apply the DO requirement for continuous swirling to a pH reading.

Original temperature, salinity and pressure display examples
Temperature and salinity compensation are automatic; P3 barometric pressure is entered manually. The illustrated 101.3 is kPa, equal to 1013 mbar, not 101.3 mbar. The artwork does not guarantee accuracy under unsuitable sample conditions.

Understand the sensing end and connections.

SX725 connected to the 201T-S pH electrode
The 201T-S supplies pH and temperature through one 8-pin connection. Its KCl storage bottle is removed before testing.
Manufacturer panel showing separate SX725 pH and DO configurations
Left: 201T-S for pH and temperature. Right: DO500 for oxygen and temperature. These are alternative connections, not simultaneous channels.
Labeled DO500 temperature and salinity sensors, anode, cathode and membrane cap
Original DO500 anatomy: temperature and salinity sensors sit above the replaceable membrane cap; the silver anode and gold cathode are inside. This is an oxygen-consuming polarographic system, not an optical sensing cap.

Keep the membrane clean.
Keep the sleeve sponge moist.

Between uses, protect DO500 in its calibration/storage sleeve with the sponge moist from a few drops of distilled water, not dripping. Do not fill this sleeve with pH KCl storage solution. Rinse the probe after testing and inspect the membrane and electrolyte for damage or bubbles. Keep the electrical connector clean and dry.

Replace a wrinkled, cracked or damaged membrane, or investigate slow response and obvious errors. Unscrew the cap, rinse the exposed electrode with distilled water and shake off excess. Wipe the gold cathode with clean tissue. Slowly add fresh DO502 to a new DO503 cap without bubbles, stand it on a table and screw the electrode vertically into it. Wipe expelled electrolyte, rinse and check again for bubbles; reassemble if necessary.

For a contaminated gold cathode, use DO504 polishing paper lightly along the curved gold surface, then clean, rinse and refill as instructed. Never brush the platinum-black salinity sensor; swirl it in pure water instead. Re-polarize after fresh electrolyte and recalibrate before measurement. Handle electrolyte with appropriate protection and consult its safety instructions.

The 201T-S needs different storage: keep its glass bulb in the supplied KCl storage bottle, never in pure water. Its gel reference electrolyte is not refillable. Rinse before and after pH use; never rub the glass membrane. Do not transfer DO500 electrolyte or cathode-polishing instructions to the pH electrode.

The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.

Three replacement DO503 membrane caps
Three spare DO503 caps are supplied. Avoid touching the membrane faces; replace damaged, wrinkled or cracked membranes and investigate slow response.
DO502 inner-solution refill bottle
DO502 is the 30 mL electrolyte refill for the membrane assembly, not a calibration standard or pH storage liquid. Fill slowly without bubbles and re-polarize after refilling.
Original numbered DO500 sleeve and electrode diagram
Original diagram legend: 1 DO500; 2 sleeve cap; 3 sleeve; 4 water-moistened sponge; 5 bottom lid; 6 temperature sensor; 7 membrane cap; 8 gold cathode; 9 silver anode; 10 salinity sensor. Keep the sponge moist, not dripping.
Original manual display diagram with numbered indicators
Display legend: 1 parameter; 2 result; 3 record number and M+/RM; 4 unit; 5 temperature; 6 stability smile; 7 calibration status; 8 low battery. The all-segment diagram explains the screen and is not a sample reading.
Original electrode connection and locking-ring illustration
Align the notches and push straight in while holding the metal ring, then tighten the ring. To remove, loosen the ring and pull straight out. Never twist the black rubber part. One electrode connects at a time.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Save 300 sets.
Recall locally and keep a separate field log.

When the smile remains on screen, a short press of M+/RM stores the reading. SX725 holds up to 300 sets containing serial number, measurement value, unit and temperature. The manual states 300 sets for the meter, not 300 per mode; it does not specify a per-mode allocation.

A long press recalls the last saved record; use the review keys to browse. The manual’s delete operation in recall mode clears all saved data, so transcribe needed readings first. No date/time fields, real-time clock setting, timed automatic logging, USB, Bluetooth or PC-Link export workflow is documented for this model. “Data logging” here means operator-initiated save and recall.

M plus and RM record indicators from the original LCD diagram
M+ accompanies a manually saved reading; RM identifies a recalled reading. Record numbers are not timestamps. 300 sets are available on this model; no timed logging or computer export is documented.

Compare another measurement format.

Related workflow: Apera DO850 Portable Optical Dissolved Oxygen Meter Kit, 10-ft Cable | AI480. The linked optical DO kit has a different sensor technology and maintenance workflow; its probe or cap is not interchangeable with DO500. It is a DO-workflow option, not a replacement for this kit’s other parameters. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

SX725 buyer questions

Is this an optical dissolved oxygen meter?

No. The included DO500 uses a polarographic membrane system with electrolyte, a gold cathode and silver anode. It consumes oxygen and requires polarization and water movement. DO803 optical-probe claims, no-flow claims and optical-cap warranty terms do not apply.

How long does a DO measurement take?

Allow five minutes after power-on, or 30 minutes after fresh electrolyte or a new cap. The ≤30-second specification is 90% response at 25°C. The manual’s field procedure typically takes one to five minutes and requires actual stability, temperature equilibration and continuous movement in still water.

What calibration solutions are included?

DO502 is 30 mL of electrode electrolyte, not a DO calibration standard. Routine oxygen calibration uses the moist sleeve. Sodium sulfite for optional zero calibration and 12.88 mS/cm salinity standard are not listed in the kit. SX725 also includes 50 mL each of pH 4.00, 7.00 and 10.01 buffer.

Can pH and DO be measured at the same time?

No concurrent pH/DO workflow is documented. Connect one 8-pin electrode at a time; recognition selects the appropriate parameter. Temperature is read with that electrode. ORP requires a separately purchased suitable electrode; no ORP probe is in AI465.

Which temperature limits matter?

The meter’s operating environment is 5 to 35°C at ≤85% humidity. DO compensation covers 0 to 45°C, while the current DO500 listing gives a 0 to 50°C probe range. These are different limits. The current 201T-S listing specifies 0 to 13 pH and 0 to 60°C; its PDF lists wider ranges. Use the narrower current probe limits and avoid prolonged high-temperature work. The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.

Are the caps, electrolyte and service tools supplied?

Yes: three spare DO503 membrane caps, one 30 mL DO502 refill, two pieces of DO504 cathode-polishing paper, a screwdriver, two spare AA batteries, manual and case accompany the meter and DO500. The probe includes its calibration/storage sleeve. AI465 adds a 201T-S electrode and three 50 mL pH buffers.

Can I export records or automatically log a time series?

The exact manual documents 300 manually saved sets with on-meter recall. It does not document timestamps, a logging interval, USB, Bluetooth or computer export. Preserve time, sample identity and readings in your own field record. Do not assume separate 300-record banks for different units or modes.

What warranty applies to the meter, probes and consumables?

The current US SX725 listing and v3.0 meter manual state three years for the instrument and six months for the probes from delivery, for covered material or workmanship defects, with repair or replacement at Apera’s option. They exclude normal wear, accidental damage, improper use or storage, transportation damage, neglected instructions or maintenance, unauthorized repair or modifications and external causes. No separate fixed warranty duration is published for DO503 membrane caps or DO502 refill in the reviewed product pages; do not assume optical-cap coverage or free routine consumable replacement.

Confirm the exact configuration before ordering.

Review SX725 AI465 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    pH meter range / resolution-2.00 to 19.99 pH / 0.1 or 0.01 pH
    pH accuracyCurrent listing: ±0.01 pH ±1 digit; manual: meter ±0.01, overall ±0.02 pH
    pH calibration1 to 3 points; USA, NIST or China buffer series
    pH automatic temperature compensation0 to 100°C meter capability; supplied probe limits apply
    201T-S current probe range0 to 13 pH; 0 to 60°C The current 201T-S listing excludes low-ion water, strong-base samples above pH 12 and highly corrosive liquids. Its probe guide also cautions against frequent testing below pH 2 or above pH 12 and prolonged exposure above 50°C; 0 to 60°C is not a continuous-use guarantee.
    mV mode, optional electrode-1999 to 1999 mV; 1 mV resolution; manual meter accuracy ±0.1% FS; overall ±15 mV
    DO range0 to 19.99 mg/L (ppm); 0 to 200.0%
    DO resolution0.01 or 0.1 mg/L (ppm); 0.1 or 1%
    DO accuracy±0.30 mg/L (ppm), including electrode error
    DO response≤30 seconds at 25°C to 90% response
    DO sensorDO500 polarographic; 8-pin connector
    DO automatic temperature compensation0 to 45°C
    Automatic salinity compensation0 to 45 ppt
    Manual pressure compensation66 to 200 kPa (660 to 2000 mbar equivalent)
    DO calibrationRoutine 100% water-saturated air; optional 0% per manual
    DO500 probe operating range0 to 50°C; temperature accuracy ±0.5°C
    Meter operating environment5 to 35°C; ≤85% humidity; IP57
    Internal storage300 sets; serial number, value, unit and temperature
    PowerTwo AA alkaline batteries, 1.5 V each
    Meter size / weight65 × 120 × 31 mm / 180 g

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI465
    Blue Tiger SKUBTS-AI465
    Order unit1 exact listed meter-kit configuration
    Order contentsSX725 meter: One handheld instrument.; DO500 polarographic DO electrode: One 8-pin probe with temperature/salinity sensors and calibration/storage sleeve.; 201T-S pH/temperature electrode: One 8-pin combination electrode with KCl storage bottle.; pH calibration buffers: pH 4.00, 7.00 and 10.01; one 50 mL bottle each.; DO502 inner solution: One 30 mL bottle of DO electrolyte.; DO503 membrane caps: Three spare caps.; DO504 polishing paper: Two pieces for the gold cathode.; Service and transport items: One screwdriver, two spare AA batteries, operation manual and carrying case.

    Apera Manufacturer Limited Warranty

    The current US SX725 listing and v3.0 meter manual state three years for the instrument and six months for the probes from delivery, for covered material or workmanship defects, with repair or replacement at Apera’s option. They exclude normal wear, accidental damage, improper use or storage, transportation damage, neglected instructions or maintenance, unauthorized repair or modifications and external causes. No separate fixed warranty duration is published for DO503 membrane caps or DO502 refill in the reviewed product pages; do not assume optical-cap coverage or free routine consumable replacement.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

    SX725 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat