Apera ORP60-E Replacement ORP Probe for ORP60 Default Title Replacement Probe Apera Instruments
Apera ORP60-E Replacement ORP Probe for ORP60 Default Title Replacement Probe Apera Instruments

Apera ORP60-E Replacement ORP Probe for ORP60

$60.00

    Renew the ORP sensor on your pocket tester.

    • ORP60-E · AI1207; one replacement probe
    • For ORP60; also listed for PH60, PH60F and PH60S for ORP use
    • Platinum ORP sensor; 30 kΩ thermistor; −1000 to 1000 mV
    • Six-month probe warranty

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / ORP60-E / AI1207

Renew the ORP sensor on your pocket tester.

Apera ORP60-E is the standard replacement probe for the ORP60 tester. Its platinum sensing element, single ceramic junction and built-in temperature sensor are designed for ORP testing in general water solutions. Apera also lists compatibility with PH60, PH60F and PH60S for ORP use.

This page supplies one ORP60-E replacement probe (AI1207), not a complete tester. Apera’s probe warranty is six months from delivery.

Apera ORP60-E replacement ORP probe
Apera ORP60-E replacement ORP probe.
Choose your replacement probeClick or tap to compare 6 probe familiesCompare the models below - click or tap here to close

Only published products are linked. Other cards provide model-comparison information and do not indicate current storefront availability.

Check the tester and measurement role.

Replacement probe Fit and sensing role
ORP60-E · AI1207 ORP60 replacement; also listed for PH60, PH60F and PH60S for ORP use. Platinum sensor; single ceramic junction; 30 kΩ thermistor.

ORP60-E is the replacement for ORP60. PH60, PH60F and PH60S are also named by Apera. It measures ORP rather than pH when fitted to these pH testers. Do not infer a PC60 or ZenTest -Z fit.

For ZenTest hosts, see Alternative format: ORP60-DE (dedicated replacement for ORP60-Z) or Alternative format: ORP60-DA (adds ORP to PH60-Z, PH60F-Z, PH60S-Z and PC60-Z). These are distinct host roles, not interchangeable suffixes or options on this page.

Apera ORP60-E replacement ORP probe
Apera ORP60-E replacement ORP probe.

What makes it work.

Platinum ORP sensing

A platinum sensing element measures oxidation-reduction potential in general aqueous samples.

Single ceramic junction

ORP60-E uses a single ceramic junction, an Ag/AgCl reference and gel KCl electrolyte.

Integrated temperature sensor

The exact ORP60-E instruction sheet specifies a 30 kΩ thermistor. Display and calibration behavior depend on the supported host tester.

Apera ORP60-E replacement ORP probe
Apera ORP60-E replacement ORP probe.

Check the specifications.

ORP60-E specifies −1000 to 1000 mV, 0–50°C operation, a platinum ORP element and a 30 kΩ thermistor. ORP checks use a temperature-appropriate reference value; they are not pH-buffer calibration.

See the Product Specifications tab for the exact-model specifications and ordering information.

Care and storage.

Rinse the ORP sensor after use and keep the probe cap secure. Use the supported host’s ORP conditioning and cleaning procedure; keep mating contacts dry. The ORP60 host manual specifies 3M KCl for activation, while the exact ORP60-E sheet recommends 15–30 minutes in 222 mV ORP standard to improve response.

Check the reading against the ORP standard’s value at the actual temperature. The ORP60 manual gives a host-specific ORP calibration procedure when needed. Do not apply a pH-buffer calibration or copy cleaning instructions for platinum-black conductivity rods onto the ORP sensor.

Related items.

Check readings against Apera 222 mV ORP standard.

ORP60-E buyer questions

Which tester is ORP60-E made for?

It is the replacement for ORP60. Apera’s exact product page also lists PH60, PH60F and PH60S for ORP use; these are Premium hosts, not ZenTest -Z bodies.

Does ORP60-E measure temperature?

Yes. The exact ORP60-E instruction sheet specifies a built-in 30 kΩ thermistor. This is different from the separately sold ORP60-DA sheet’s N/A temperature-sensor entry.

What are its measuring and operating ranges?

The probe sheet specifies −1000 to 1000 mV and 0–50°C operation. Overall accuracy and displayed functions depend on the supported tester.

Will it measure pH as well as ORP?

No. ORP60-E has a platinum ORP sensor, not a pH-glass measuring element. Fitting it to a compatible pH tester changes the installed sensing role to ORP.

Is ORP60-E the replacement for ORP60-Z?

No such E-to-Z fit is claimed here. ORP60-DE is the dedicated ORP60-Z replacement; ORP60-DA is the different ORP add-on for the named ZenTest PH/PC models. See the Alternative format links.

How do I replace ORP60-E?

Remove the cap, unscrew the probe ring, unplug the old probe, align and seat the replacement, then tighten the ring. Keep the electrical contacts clean and dry. Check/condition it as directed by the ORP60-E sheet and supported host manual.

Can 222 mV solution improve response?

Yes. The exact ORP60-E sheet recommends a 15–30-minute soak in 222 mV ORP standard to improve performance. Use the standard’s temperature-dependent value when checking the reading.

Does an ORP check use the pH calibration procedure?

No. Use the supported host’s ORP procedure. The ORP60 host manual explains checking with ORP standard and calibration when needed; do not use pH buffers or assume another model’s acceptance tolerance.

Confirm your model before ordering.

Order ORP60-E (AI1207) for the supported tester and sensing role listed above. This is one replacement probe.

Back to ordering ↑
    SpecificationDetail
    ModelORP60-E
    Compatible hostsORP60; PH60, PH60F and PH60S also listed by Apera for ORP use
    Measurement roleORP and temperature; not pH or conductivity
    ORP range−1000 to 1000 mV
    SensorPlatinum
    Junction / referenceSingle ceramic / Ag/AgCl
    ElectrolyteGel KCl
    Temperature sensor30 kΩ thermistor — specified in the ORP60-E instruction sheet
    Operating temperature0–50°C
    HousingPolycarbonate
    Manufacturer warrantySix months from delivery

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI1207
    Blue Tiger SKUBTS-AI1207
    Available modelORP60-E — AI1207
    Order unit1 replacement probe; tester not included

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this product to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat