APERA INSTRUMENTS / PH700-BC / AI5018
Build a dedicated bench station for biological liquids, TRIS buffers and liquid food samples. PH700-BC pairs the PH700 meter with the refillable LabSen 823 pH/temperature electrode, bringing a silver-ion-trap reference, three ceramic junctions and Protelyte electrolyte to protein-containing samples.
Choose this configuration for its sample-facing reference system, not a different meter accuracy claim. The supplied glass electrode is intended for liquids, not penetration into solid foods.
Each card opens that product page. Different kits supply different probes and care methods. The 201T-F card is an electrode-only base-kit replacement, not an extra specialty electrode supplied with these kits.
AI501
General-water base kit
201T-F BNC/RCA probe; different from the specialty configurations.
AI5018
Protein / TRIS / biotech
LabSen 823; Protelyte refill and storage.
AI5012
Dirty liquids / suspensions
LabSen 333; nonrefillable polymer and KCl storage.
AI5015
Pure / low-ionic water
LabSen 803; movable sleeve and defined pure-water method.
AI5016
Viscous formulations
LabSen 853-H; sealed pre-pressurized reference.
AI5017
Precious small samples
LabSen 241-3SP; micro-container and manual-temperature method.
AI5013
Strong acid / HF
LabSen 833; HF-type glass, refillable 3M KCl.
AI5011
Strong alkali / high salinity
LabSen 843; HA glass for low alkaline error.
AI5019
Hot / caustic / plating baths
LabSen 863; PTFE junction, non-refillable gel.
AI1302
REPLACEMENT ELECTRODE ONLY
Compatible base PH700 sensor; not a complete meter kit.
The silver-ion-trap reference and Protelyte solution are designed to reduce protein-related junction fouling. Three ceramic junctions provide the reference contact with the sample; cleaning remains part of the method.
LabSen 823 combines pH and an NTC 30 kΩ temperature sensor. Connect blue BNC to pH/mV and black RCA to TEMP for automatic temperature compensation.
The visible glass body lets the operator check the reference-solution level. Maintain it with the specified Protelyte solution rather than treating this as a sealed, disposable reference system.
A focused option for protein-containing laboratory liquids. Match sample composition, cleaning and calibration to the work; suitability is not a clinical diagnostic claim.
Select the protein/TRIS-oriented reference system for compatible formulations. The kit does not replace a validated pharmaceutical test procedure.
Use for appropriate milk, yogurt, sauce and related liquid samples. Confirm consistency and immersion requirements rather than assuming every thick or solid food can be tested directly.
Before measurement, remove the storage vial, rinse the electrode and open the blue refill plug so reference solution can flow as intended. Secure the electrode in the simple holder without letting the glass tip strike the vessel.
Perform at least a two-point calibration before first use. Start at the neutral standard for the selected buffer series, then choose additional points around the expected sample. Use clean portions of buffer and rinse between standards and samples.
Immerse the sensing tip and junctions appropriately, then allow the reading to stabilize. Automatic temperature compensation addresses electrode response, not every temperature-dependent change in the sample. Strong chemistry, dehydrating media, pure water and extreme-temperature work require separate suitability review.
Use Protelyte AI1190 inside the refillable reference and in the external storage vial. When the reference level falls to about half the electrode height, replenish it through the refill opening as instructed. Do not substitute generic KCl.
After testing, rinse away sample residue, return the electrode to its Protelyte storage vial, tighten the cap and close the refill plug. Replace contaminated soaking solution. Distilled or deionized water is for rinsing, not long-term storage.
Protein deposits need attention before they affect the next measurement. Follow the electrode-specific cleaning, conditioning and recalibration instructions. Keep connectors clean and dry. Additional Protelyte and refill tools are maintenance purchases, not extra items promised in the kit.
PH700 supports 1-3 pH calibration points and 50 manually saved sets shared across pH/mV. The instrument display range is 0-14.00 pH with selectable 0.01/0.1 pH resolution and stated ±0.01 pH ±1 digit accuracy; these do not establish unrestricted probe/matrix accuracy.
M+ saves a stable result and RM recalls it. No documented USB/PC export, automatic interval recording, date/time field or certified audit trail is promised. Optional ORP needs a separate appropriate ORP electrode; the supplied pH electrode in mV mode gives its pH signal, not ORP.
This manufacturer electronics illustration refers to the PH700 instrument. Appropriate electrode selection, calibration and sample handling still govern the result. It does not establish extra logging/export features or a separately tested performance guarantee.
BC includes the refillable glass LabSen 823 with a silver-ion-trap reference and Protelyte for protein/TRIS work. The wastewater kit uses a different, nonrefillable open-junction electrode. Choose by sample type, not appearance.
Protelyte AI1190 serves both tasks: internal reference refill and external wet storage. Generic KCl and pure water are not substitutes. Keep the storage cap and refill plug closed between uses.
No. LabSen 823 includes temperature sensing. Its blue BNC connector carries pH/mV and its black RCA connector carries temperature. Both connect to the supplied PH700.
A BNC socket alone does not establish full compatibility. The other meter must also support the RCA temperature connection and the NTC 30 kΩ sensor. Confirm the complete interface first.
No. Check sample chemistry, consistency, temperature and cleaning requirements. The probe is not a universal solvent, solid-food, strong-acid or strong-alkali sensor.
No. The meter display interval is not an unrestricted probe or sample rating. Confirm electrode suitability before extreme-pH or extreme-temperature use; this configuration is not presented as a subzero system.
PH700, one LabSen 823 electrode, one holder, a 9V adapter, three 50 mL buffers at pH 4.00, 7.00 and 10.01, and the user manual. The electrode has a storage vial/cap.
No separate Protelyte bottle, syringe, pipette or ORP electrode is listed. Beakers, USB cables, carrying cases and a separate temperature probe are not supplied kit components.
Review PH700-BC AI5018 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.
APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.
This limited warranty does NOT cover any issues due to:
Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.