Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Default Title Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Default Title Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments
Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode Value Portable pH Meter Apera Instruments

Apera PH850-MT Portable Meat pH Meter Kit with LabSen 763 Blade Spear Electrode

$490.00

    Meat-focused blade protection, built-in temperature sensing and a simple portable pH workflow.

    • LabSen 763, AI3202, with integrated temperature sensing
    • Titanium blade sheath for prepared meat samples
    • Electrode range: 0 to 14 pH and 0 to 80°C
    • Sealed polymer reference; external 3M KCl storage

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH850-MT / AI5545

Meat sampling.
A protected blade spear, a clear record.

PH850-MT pairs the PH850 Value-series instrument with the LabSen 763 titanium-body blade spear pH/temperature electrode. The configuration is intended for direct measurement of prepared meat and fish samples, with a removable titanium blade sheath around the glass sensing tip.

Choose the meat-specific blade configuration for a controlled sampling station or portable quality workflow. The blade is protection for a glass sensor, not permission to force it through hard-frozen material, bone or tough connective tissue. Work within the probe limits and record results separately.

Apera PH850-MT with LabSen 763 blade spear electrode
Current manufacturer PH850-MT application composite. Food scenery is illustrative; screen values are demonstration graphics, not a food-test result.
Which 850 Value kit fits my sample?Click or tap to compare all nine configurations, including harsh-chemistry kitsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.

Harsh-chemistry kits

Choose the electrode for the sample.

A sheath designed around meat sampling

LabSen 763 combines a spear glass membrane with a titanium blade sheath. The blade can be unscrewed for separate cleaning when necessary, as described in the electrode manual. Avoid bending the spear while entering or withdrawing from a sample. Protective construction does not make any glass electrode breakproof.

Temperature travels with the pH probe

The integrated NTC 30 kΩ sensor supplies temperature through the RCA connector, while the BNC connector carries pH. This keeps temperature sensing in the electrode assembly rather than a separate loose probe. The supplied LabSen 763 is specified for 0 to 80°C, narrower than the meter temperature display range.

A sealed reference and readable instrument

Polymer electrolyte, a ceramic plus single-pore junction and the long-life reference system support direct sample contact without routine internal refilling. PH850 shows pH and temperature on a backlit screen, with stability and calibration indicators. Its IP57 instrument enclosure and protective sleeve support portable handling, not rough treatment of the glass tip.

Know what this configuration supplies.

Included item Order contents
PH850 Value-series meter One meter identified in the current PH850-MT kit illustration.
LabSen 763 blade spear pH/temperature electrode One specified electrode with BNC/RCA connections; current replacement catalog AI3202.
pH calibration solutions pH 4.00, 7.00 and 10.01 are each identified and pictured as one bottle. Exact bottle volumes are not confirmed for this specialty kit.
Carrying case, screwdriver and user manual All three are identified in the exact specialty-kit illustration; packaging may change.
Electrode storage bottle Shown protecting the electrode. Separate KCl bottle, spare supplies and battery inclusion are not verified.
Open PH850-MT carrying case with meter, LabSen 763 and calibration solutions
Photo portion of the exact PH850-MT kit illustration. It identifies the case, meter, LabSen 763, screwdriver, manual and pH 4.00, 7.00 and 10.01 buffers. Volumes, separate KCl and batteries are unconfirmed.

Match the sample and preparation method.

Prepared fresh-meat portions

Use a defined anatomical location or representative portion under your sampling plan. Avoid bone, hard inclusions and excessive resistance. Identify the cut, lot, sample temperature and preparation so differences between readings can be interpreted rather than attributed to the instrument alone.

Fish and meat-product development

The LabSen 763 manual identifies meat and fish applications. Compare like-for-like prepared samples and rinse thoroughly between portions. The meter measures pH, not protein content, pathogens or freshness, and does not replace the other tests required by your process.

Products received frozen

The manufacturer describes frozen-meat use, but the electrode specification starts at 0°C and warns against bending the spear. Prepare or condition a sacrificial portion by an appropriate procedure; do not force the probe into hard-frozen product or claim validated below-zero performance.

Protect the glass in the blade.
Protect the glass in the blade. Calibrate: Use fresh buffers. New LabSen 763: at least two points. Prepare: Use a prepared sacrificial portion. Never force frozen meat. Read: Stay within 0 to 80°C. Wait for pH and temperature stability.

Choose the sampling point.
Never lever the blade.

Attach the blue BNC and black RCA connectors securely while keeping both dry. Remove the storage bottle and rinse the sensing end with distilled or deionized water. With a newly connected LabSen 763, perform at least two-point calibration. PH850 supports one to three automatic points; in USA mode start at pH 7.00 and use an appropriate additional standard such as pH 4.00 for acidic measurements.

Set aside a representative sacrificial portion and follow your established handling and contamination-control procedure. Prepare an accessible contact path with a separate suitable tool if required. Keep insertion and withdrawal aligned with the probe rather than bending or twisting it. Stop when resistance is excessive; a blade sheath is not a guarantee against glass damage.

Let the electrode and sample equilibrate within 0 to 80°C, then read stable pH and temperature. Record the sampling position, preparation and sample ID immediately. Temperature compensation adjusts electrode response, not the meat chemistry itself. Do not compare measurements taken under different preparation conditions without accounting for those differences.

Understand the sensing end and connections.

LabSen 763 titanium blade sheath around the glass spear
Manufacturer photograph served on the exact LabSen 763 electrode page. Full probe view retained; cable extends beyond the source photograph.
Close view of LabSen 763 glass sensing tip and protective blade
Close view of the glass sensor inside the titanium blade sheath. Keep insertion aligned and avoid side-loading; protection does not make glass unbreakable.
Manufacturer dimension photograph for LabSen 763
Electrode section: Ø12 × 115 mm. Measuring tip: Ø6 × 50 mm. These are physical dimensions, not a prescribed penetration depth. Original manufacturer dimension labels retained.
LabSen 763 blue inner sensing gel comparison with convection arrows and conventional liquid-filled sensor
This comparison illustrates the LabSen 763 sensing gel, not a physical cross-section to scale. Left: blue gel inside the glass sensing tip. Centre: crossed arrows illustrate the non-flowing gel design. Right: a conventional liquid-filled sensor with a bubble. This internal gel is not storage liquid: keep the sensing end in external 3M KCl when not in use.
LabSen 763 ceramic and open junction explanatory close-ups with arrows
The enlarged circles identify the LabSen 763 ceramic junction on the left and open junction on the right. The manual lists ceramic plus single pore; the graphic labels that pore “Open Junction.” The blade sheath is omitted here to expose the sensing assembly. This is an explanatory composite, not a to-scale cross-section. The polymer reference electrolyte needs no routine refill, but the junction still needs cleaning and external 3M KCl storage.

Clean the blade and sensor.
Store the glass wet.

The LabSen 763 manual calls for washing the electrode and titanium sheath with soapy water after meat measurement. If needed, unscrew the blade sheath and clean it separately, handling the exposed glass carefully. Rinse away cleaning residues before use. This cleaning instruction is not a validated sanitation or sterilization protocol for your facility.

For persistent contamination, use the documented AI1166 cleaning-solution treatment for 30 minutes, followed by gentle soft-brush cleaning. Recondition in 3M KCl for at least one hour, rinse and recalibrate before measuring again. Inspect the blade and glass for damage; do not use a suspect probe in production sampling.

Store the sensing end in the electrode bottle with clean 3M KCl. The polymer reference is sealed and non-refillable; external KCl soaking remains necessary. Do not substitute pure water for storage. A small amount of transparent polymer may emerge after soaking; the manual permits gently wiping this excess with clean tissue. Keep connectors clean and dry.

Clean the sheath. Soak the tip.
Clean the sheath. Soak the tip. Clean: Wash probe and blade with soapy water, then rinse. Store: Keep the sensing end in clean 3M KCl, not pure water. Do not refill: Polymer reference is sealed. KCl is external storage care.
Internal Long-Life reference assembly illustration showing silver chloride marked AgCl
Inside the reference system: AgCl means silver chloride. This illustration shows the internal reference assembly, not the complete probe or a user-fillable reservoir. “Long-Life” is the reference design name, not a guaranteed lifespan. The polymer reference needs no routine refill; cleaning and external 3M KCl storage are still required.
Blue BNC pH plug and black RCA temperature plug for LabSen 763
BNC carries pH; RCA carries the integrated temperature sensor signal. Keep both plugs clean and dry. Manufacturer labels retained.
PH850 display, calibration keys and exact model label
Meter-only crop from an actual PH850 photograph. The general-purpose blue electrode has been excluded. Display values are illustrative, not a result from the supplied food probe.
PH850 LCD diagram with numbered stability, calibration and temperature indicators
Read the PH850 display: 1 is the smiley-face stability indicator; 2 marks completed low, middle and high pH calibrations (L/M/H); 3 is the simultaneous temperature reading. The numbers shown are examples. HOLD freezes the display temporarily; it does not save a measurement.

A stable reading is the start of the record.

Use the physical controls for on-meter measurement and calibration. HOLD temporarily locks a reading on screen; write the result and its sample context in your external worksheet or record system. Screen values in photographs are illustrative, not sample results.

Use calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Read the result.
Make the record yourself.

PH850 is a direct-reading Value-series instrument, not a stored-results logger. The current kit specification lists data storage, storage content and output as N/A. There is no supported computer-download or automated reporting workflow for this model.

Optional automatic HOLD freezes a stable displayed reading to help with transcription. It does not retain a batch record. Keep a notebook or worksheet with sample identity, pH, measured temperature, operator and your own date and time, alongside calibration details and any unusual drift.

Procurement note: the current US kit page lists three AA batteries, while the PH850 manual lists three AAA batteries. Confirm the supplied hardware revision and battery requirements; battery inclusion is not promised here. The current limited warranty is three years for the instrument and six months for the probe from delivery, subject to exclusions including accidental damage, misuse and normal wear.

HOLD is not memory.
HOLD is not memory. Read: Wait for stability. HOLD temporarily freezes the display. Write: Record sample ID, pH, temperature and your own timestamp. Retain: Keep your worksheet. PH850 storage and output are N/A.

Compare the Premium Series counterpart.

Alternative format: Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763. The Premium Series counterpart offers a different recordkeeping workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.

PH850-MT buyer questions

Which blade spear electrode is specified for this kit?

PH850-MT, AI5545, specifies LabSen 763. The current US electrode catalog number is AI3202. It has BNC and RCA connections and integrated NTC 30 kΩ temperature sensing; the related LabSen 761 is not the specified probe.

Can I push it straight into hard-frozen meat?

No. Do not force LabSen 763 through hard-frozen material. Although the manufacturer describes frozen-meat applications, its specified temperature range is 0 to 80°C and the manual warns against bending the spear. Prepare or condition a sacrificial portion within your validated method.

Is the titanium blade removable for cleaning?

Yes. The LabSen 763 manual says the blade can be screwed off and cleaned separately when necessary. It also calls for washing the electrode and sheath with soapy water after measurement. Handle exposed glass carefully and rinse away residue.

What is the working size of LabSen 763?

The electrode manual lists a 12 mm diameter by 115 mm electrode section and a 6 mm diameter by 50 mm measuring tip, with a 1 m cable. These dimensions are not a universal required insertion depth; establish suitable sample contact in your method.

Does KCl go inside this electrode?

No routine refill is required. LabSen 763 has polymer reference electrolyte. Use 3M KCl externally in its storage bottle to condition the glass membrane and junction; pure water is for rinsing, not storage.

What accuracy and calibration does PH850 provide?

The instrument specification is ±0.01 pH ±1 digit, with 0.01 or 0.1 pH resolution and one to three automatic calibration points. The LabSen 763 manual requires at least two points after connecting a new probe. Sample preparation remains part of measurement performance.

Can I download the measurements after a shift?

No. PH850 data storage and output are N/A. Optional HOLD temporarily freezes a reading only. Keep a separate record of lot, sampling location, pH, temperature, operator and your own time and date.

Which buffers and accessories are shown in the exact kit?

The PH850-MT manufacturer illustration shows the meter, LabSen 763, carrying case, screwdriver, manual and pH 4.00, 7.00 and 10.01 buffers. Exact liquid volumes, a separate KCl bottle and included batteries are unconfirmed. Do not infer quantities from the general PH850 kit list.

Confirm the exact configuration before ordering.

Review PH850-MT AI5545 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / current US SKUPH850-MT / AI5545
    Supplied electrode / current SKULabSen 763 / AI3202
    Instrument pH range0.00 to 14.00 pH
    pH resolution / accuracy0.01 or 0.1 pH / ±0.01 pH ±1 digit
    Calibration1 to 3 points; USA or NIST buffer series
    Electrode range0 to 14 pH; 0 to 80°C
    Meter temperature display / compensation0 to 100°C; automatic or manual compensation
    Temperature resolution / accuracy0.1°C / ±0.5°C ±1 digit
    Electrode temperature sensorIntegrated NTC 30 kΩ
    Body / membraneFood-grade titanium / blade-protected spear glass
    Reference / junctionSealed polymer / ceramic + single pore
    Electrode section / measuring tipØ12 × 115 mm / Ø6 × 50 mm
    Cable / connectors1 m / BNC for pH + RCA for temperature
    Storage solution3M KCl; external soaking, no internal refill
    Data storage / outputN/A; HOLD is temporary display lock only
    mV channel±1000 mV; separate ORP electrode required
    PowerCurrent US page: 3 AA; manual: 3 AAA. Confirm revision; inclusion unverified.
    Instrument enclosureIP57; keep connectors dry
    Limited warranty3 years instrument; 6 months probe from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI5545
    Blue Tiger SKUBTS-AI5545
    Order unit1 exact 850 Value Series kit
    Order contentsPH850 Value-series meter: One meter identified in the current PH850-MT kit illustration.; LabSen 763 blade spear pH/temperature electrode: One specified electrode with BNC/RCA connections; current replacement catalog AI3202.; pH calibration solutions: pH 4.00, 7.00 and 10.01 are each identified and pictured as one bottle. Exact bottle volumes are not confirmed for this specialty kit.; Carrying case, screwdriver and user manual: All three are identified in the exact specialty-kit illustration; packaging may change.; Electrode storage bottle: Shown protecting the electrode. Separate KCl bottle, spare supplies and battery inclusion are not verified.

    Apera Manufacturer Limited Warranty

    Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.

    Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.

    PH850-MT official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; battery and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.