Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Default Title Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Default Title Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments
Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763 Specialty Portable pH Meter Apera Instruments

Apera PH8500-MT Portable Meat pH Meter Kit with LabSen 763

$675.00

    A blade-spear meat probe with temperature sensing and USB records.

    • LabSen 763 pH/temperature electrode, AI3202
    • BNC pH plus RCA temperature connections
    • Sealed polymer reference; 3M KCl wet storage
    • 500 dated sets with manual or interval logging

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH8500-MT / AI5558

A blade-protected probe.
A consistent meat-testing method.

PH8500-MT pairs the PH8500 portable meter with the LabSen 763 titanium blade-spear pH/temperature electrode for meat and fish. Its protective blade supports direct sample insertion, while the built-in temperature sensor supplies automatic temperature compensation. Choose a prepared test portion that respects the probe’s temperature and mechanical limits.

This is the AI5558 configuration with LabSen 763, catalog AI3202. It is not the PH60-MT configuration with LabSen 765. The blade is a preparation aid, not permission to force a probe into rock-hard frozen food.

PH8500-MT meter with LabSen 763 probe and illustrative food samples
PH8500-MT with LabSen 763. Food samples are illustration props, not kit contents.
Which 8500 portable configuration fits my work?Click or tap to compare all nine configurations, including harsh-chemistry kitsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.

Harsh-chemistry kits

Choose the electrode for the sample.

Reference contact for food samples

Ceramic and open junction contact works with a sealed polymer reference electrolyte. The Long-Life reference uses silver and silver chloride. Blue gel inside the sensing system is a different material; neither is replaced by pouring storage solution into the electrode.

Temperature travels with the reading

LabSen 763 includes an NTC 30 kΩ temperature sensor. Connect blue BNC to pH and black RCA to temperature. Automatic compensation adjusts electrode response; it does not make samples measured at different temperatures chemically identical.

Portable controls, readable results

A backlit LCD shows pH, temperature, calibration indicators and stability status. The silicone sleeve supports handling, and an integrated fold-out stand supports bench use. The IP57 meter housing does not remove the need to keep electrical connectors clean and dry.

Know what this configuration supplies.

Included item Order contents
PH8500 meter Portable pH/mV/temperature instrument with integrated fold-out stand
LabSen 763 electrode AI3202; blade spear pH/temperature probe with BNC/RCA connections
Calibration solutions pH 4.00, 7.00 and 10.01
USB cable Meter-to-computer connection
Software flash drive PC-Link software media
Screwdriver Kit accessory
Carrying case Protective transport and storage case
User manual Meter operation and setup instructions
Open PH8500-MT carrying case with meter, probe, calibration bottles and accessories
Model-specific case photograph. The verified supplied pieces are listed below; no buffer volume or battery inclusion is inferred.

Match the sample and preparation method.

Meat and fish portions

Use a consistent sampling location and a portion that permits straight insertion. Allow the sample and temperature reading to settle before recording.

Chilled or previously frozen samples

Prepare or temper the test portion within the probe’s 0 to 80 °C range. Record preparation and temperature so chilled and thawed results are not treated as interchangeable.

Repeated process measurements

Use the same preparation, calibration and stabilization rules across runs. If your procedure requires a homogenate or slurry, follow that method instead of assuming direct-insertion results are equivalent.

LabSen 763 blade spear shown entering a meat portion, with tip detail inset
Manufacturer application illustration. Prepare overly hard portions and keep measurements within the probe’s 0 to 80 °C range.

Prepare the portion before the probe enters.

Connect both LabSen 763 plugs, remove the storage bottle and rinse with distilled or deionized water. Perform at least a two-point calibration when first connecting the electrode, using fresh portions of appropriate buffers. Rinse between buffers and samples; do not return used buffer to its original bottle.

Insert the blade-spear straight without bending or levering the tip. The LabSen 763 manual includes raw and frozen meat, but its specified operating range starts at 0 °C. Do not interpret “frozen” as unrestricted subzero operation. Prepare or temper hard portions before measurement; stop if insertion would require excessive force.

Wait for a stable pH indication and settled temperature, then save the reading with the sample identity in your working record. Use a sacrificial test portion and discard it after testing rather than returning it to food for consumption. A pH reading alone does not establish food safety or pathogen control.

Food sample decision guide: use moist penetrable portions, prepare hard samples, respect probe limits
Original workflow diagram. Follow the established sampling procedure; direct insertion and slurry results are not automatically interchangeable.

Understand the sensing end and connections.

LabSen 763 titanium blade-spear probe with dimensional callouts
LabSen 763: 115 mm electrode and 50 mm measuring-tip dimensions are not minimum insertion depths.
Blue BNC pH plug and black RCA temperature plug
BNC carries pH; RCA connects the built-in NTC 30 kΩ temperature sensor. Not an 8-pin connection.

Clean the contact surfaces. Keep the tip wet.

After meat testing, wash the electrode and titanium sheath with soapy water, then rinse thoroughly. The LabSen 763 blade can be unscrewed for separate cleaning when necessary. Avoid bending the spear during handling and follow your laboratory’s contamination-control procedure between samples.

For stubborn contamination, the probe manual specifies Apera AI1166 cleaning solution for 30 minutes, followed by gentle brushing. Then soak in 3M KCl for at least one hour, rinse and recalibrate. Cleaning and storage are separate steps; neither replaces checking calibration after treatment.

Store the electrode in its bottle with 3M KCl, never distilled or deionized water. Replace contaminated storage solution. This is a non-refillable polymer-reference electrode. A small amount of polymer may swell at the junction during KCl soaking; the manual permits wiping that excess with clean tissue.

Care guide separating 3M KCl wet storage from sealed polymer reference electrolyte
Original care diagram. Storage solution keeps the tip wet; it does not refill the sealed polymer reference.
PH8500 front panel with LCD and calibration, mode, memory and setup keys
PH8500 controls and display. The photographed MTC screen is an example, not a sample result.

A stable reading is the start of the record.

Use the physical meter controls for measurement and calibration, then record or save a stable result. A held display and a stored record are different functions. Screen values in photographs are illustrative, not measurements of your sample.

Choose the correct buffer family and calibration points for the intended work. Temperature compensation addresses electrode response; it does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the exact probe instructions before extending the method to a new sample.

Record locally.
Transfer deliberately.

The PH8500 can retain up to 500 sets with date, time, measurement value, unit, temperature and the last calibration record. Manual saving follows a stable indication. Timed logging can be configured from one minute to 99 hours 59 minutes. Keep the clock and sample identification procedure consistent; deleting stored values cannot be undone.

The current Web PC-Link workflow uses USB with a compatible desktop Chrome or Edge browser on Windows or Mac. It supports CSV output and browser-print reporting. Check the exact instructions and connection before relying on a field data workflow; do not assume Firefox, Bluetooth or ZenTest support.

When connected to PC-Link, new records go to software rather than meter memory. Export and back up important records before closing the tool. This does not establish automatic permanent backup, an immutable audit trail, electronic signatures, regulatory compliance or guaranteed background operation.

Data flow diagram separating meter memory from new USB-connected PC-Link logs
Original data-flow diagram. Connected readings go to software rather than meter memory; export and back up before closing.

Compare a general-water configuration.

Alternative configuration: Apera PH8500 general-water kit with 201T-F. That kit supplies a different electrode. Choose the sample-facing sensor and method rather than treating a common meter body as universal sample compatibility.

PH8500-MT buyer questions

Which probe is actually supplied?

PH8500-MT, SKU AI5558, supplies LabSen 763, catalog AI3202. The 763 uses a titanium blade sheath, built-in temperature sensor and BNC/RCA plugs. It is not the 8-pin LabSen 765.

Can it pierce any solid or frozen sample?

No. The LabSen 763 blade supports meat insertion, but avoid bending and forcing the tip. Prepare overly hard portions and keep measurement within 0 to 80 °C; deep-frozen, subzero performance is not specified.

How deep must I insert the probe?

No numeric minimum insertion depth is specified in the exact probe manual. Establish full sample contact with the sensing tip and junction. The 50 mm tip and 115 mm electrode dimensions are not minimum-immersion instructions.

Does the meter’s range equal the probe’s range?

No. The current meter manual specifies -2.00 to 16.00 pH and -10 to 110 °C temperature display. The supplied probe is specified for 0 to 14 pH and 0 to 80 °C; stay within those narrower limits.

Does 3M KCl refill the electrode?

No. Use 3M KCl to keep the tip wet in its storage bottle. The polymer reference is sealed and non-refillable. Do not substitute pure water for storage or mistake blue sensing gel for a refillable liquid reservoir.

How are readings saved?

The meter stores 500 dated and timed sets. Use manual M+ saving or timed logging from one minute to 99 hours 59 minutes. Set the clock and select a logging interval that suits the sampling procedure.

What happens when I connect USB?

PC-Link transfers readings to a computer. New connected logs go to the software instead of meter memory. Use desktop Chrome or Edge for Web PC-Link, export CSV before closing, and manage backups. This is not Bluetooth or ZenTest.

What warranty applies?

Apera’s limited warranty runs from delivery: three years for the instrument and six months for the probe. Covered defects are repaired or replaced at Apera’s option. Exclusions include accidental damage, misuse, normal wear, transport or storage damage, failure to follow instructions, unauthorized work or combinations, and external causes beyond Apera’s control.

Confirm the exact configuration before ordering.

Review PH8500-MT AI5558 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Kit / current SKUPH8500-MT / AI5558
    Supplied electrode / catalogLabSen 763 / AI3202
    Probe pH / temperature limits0 to 14 pH / 0 to 80 °C
    Meter pH range / resolution-2.00 to 16.00 pH / 0.01 or 0.1 pH
    Meter pH accuracy±0.01 pH ±1 digit
    Meter temperature range / accuracy-10 to 110 °C / ±0.5 °C
    Temperature compensationAutomatic or manual, 0 to 100 °C; probe limits still apply
    CalibrationAutomatic 1 to 3 points; USA, NIST or custom buffers
    Probe body / junctionFood-grade titanium blade sheath / ceramic + single pore (open)
    Reference / electrolyteLong-Life silver/AgCl / sealed polymer, non-refillable
    Sensor / connectorsNTC 30 kΩ / BNC pH and RCA temperature
    Probe dimensions / cableElectrode Ø12 × 115 mm; tip Ø6 × 50 mm; 1 m cable
    Storage solution3M KCl; for wet storage, not internal refill
    Data / interface500 sets with date/time; USB PC-Link
    Power / meter protection3 AA batteries or USB power / IP57
    Limited warrantyThree years instrument; six months probe; from delivery

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI5558
    Blue Tiger SKUBTS-AI5558
    Order unit1 exact specialty meter kit
    Order contentsPH8500 meter: Portable pH/mV/temperature instrument with integrated fold-out stand; LabSen 763 electrode: AI3202; blade spear pH/temperature probe with BNC/RCA connections; Calibration solutions: pH 4.00, 7.00 and 10.01; USB cable: Meter-to-computer connection; Software flash drive: PC-Link software media; Screwdriver: Kit accessory; Carrying case: Protective transport and storage case; User manual: Meter operation and setup instructions

    Apera Manufacturer Limited Warranty

    Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.

    Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.

    PH8500-MT official documents

    Use the common meter instructions for meter operation and the exact electrode instructions for its contact, cleaning and storage method. Generic base-kit packing lists do not establish specialty-kit contents. Each card opens a verified PDF in a new tab.