PH850-BR pairs the PH850 Value-series portable meter with the refillable LabSen 213 glass pH/temperature electrode. It is the beverage-oriented configuration for beer, wine, juice, kombucha, coffee and compatible general aqueous solutions, with direct readings rather than electronic sample storage.
Choose BR for a repeatable beverage sampling routine and a separately maintained production or laboratory log. LabSen 213 provides integrated temperature measurement and a maintainable 3M KCl reference. This is a glass liquid-sample electrode, not a spear probe for grain beds, fruit or solid ingredients.
Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.
AI5543
Food and semi-solids
LabSen 753 spear; prepared sacrificial samples.
AI5545
Meat sampling
LabSen 763 blade-spear; a controlled preparation method.
AI5535
Protein-containing and liquid-food samples
Refillable LabSen 823 with specified Protelyte care.
AI5533
Beverage making
LabSen 213 glass electrode with 3M KCl care.
AI5537
Prepared moist soil
LabSen 553; direct and slurry methods stay distinct.
AI5560
Wet flat surfaces
LabSen 373; wet the sensing glass and junction.
Harsh-chemistry kits
AI5529
Strong acid & HF
LabSen 833: HF-type glass, ceramic junction.
AI5527
Strong alkali & high salinity
LabSen 843: HA (high-alkali) glass, ceramic junction.
AI5564
Hot, complex & caustic liquids
LabSen 863: PHY glass, PTFE ring junction.
LabSen 213 combines an S-type hemispherical sensing membrane, a ceramic junction and a Long-Life reference. The refillable 3M KCl system supports routine aqueous sample measurement. Its lead-free glass body is 12 mm in diameter with a 120 mm specified length; handle it as laboratory glassware rather than a stirring tool.
LabSen 213 incorporates an NTC 30 kΩ temperature sensor. The meter displays temperature alongside pH and supports automatic compensation. This corrects the electrode response, not the sample’s chemistry. A warm sample can genuinely differ from the same sample after cooling, so report temperature with pH.
The LCD provides a stability symbol and completed-calibration indicators. A protective sleeve, fold-out stand and IP57 instrument enclosure support portable use. Automatic buffer recognition and selectable stability criteria help standardize operation, while the operator remains responsible for calibration quality, clean connections and a separate record of each result.
Follow pH in collected beer, wort or kombucha samples using a consistent sampling and temperature routine. Avoid pressing the glass electrode into a grain bed or using it to break up solids. Sampling stage, treatment and temperature should be recorded so that readings can be compared meaningfully.
Measure suitable aqueous wine and juice samples after calibration with buffers appropriate to the expected range. Rinse between samples to reduce carryover, and inspect the junction for residues. The electrode is not intended for prolonged exposure to dehydrating media such as absolute ethanol.
The specified operating envelope permits suitable warm liquid measurements up to 100°C. The maximum rating is not a recommendation to test every drink at boiling temperature. Establish a repeatable sample temperature, handle hot liquid safely and wait for both temperature and pH to stabilize.
Connect the blue BNC plug for pH and the black RCA plug for temperature. Remove the storage bottle, rinse the sensing end with distilled or deionized water, and open the blue refill plug so electrolyte can flow. Inspect the reference level before starting. A newly connected LabSen 213 requires at least a two-point calibration before measurement.
The PH850 recognizes USA or NIST buffers and supports one to three calibration points. In USA mode, begin with pH 7.00 and add suitable points for the expected sample range. Use fresh portions of buffer and rinse between solutions. Do not pour used buffer back into its bottle; a displayed calibration indicator cannot establish that a contaminated standard was valid.
Use the same collection point, preparation and target measurement temperature when comparing beverage batches. Where your method calls for cooling or degassing, perform it consistently rather than changing treatment between samples. Immerse the sensing membrane and junction adequately, allow the reading to settle, and use the stability symbol as an aid rather than an automatic pass/fail decision.
When the reference solution falls to about half the electrode height, refill through the opening with 3M KCl. The LabSen 213 instructions specify 3M KCl for both reference refill and external soaking, with AI1107 identified for storage. Do not substitute Protelyte solely because another beverage or food electrode uses it.
Rinse sample residue from the electrode before and after use. Return it to the storage bottle containing clean 3M KCl, tighten the cap and close the refill plug. Replace contaminated or insufficient solution. Pure water is appropriate for rinsing, not long-term storage. Keep the BNC and RCA connectors clean and dry even though the instrument itself has an IP57 rating.
For tough contamination, the exact electrode manual specifies Apera AI1166 cleaner for 30 minutes, gentle removal with a soft brush, then at least one hour in 3M KCl. Rinse and recalibrate before measuring again. Do not scrape the glass membrane. The electrode manual advises avoiding strong acids, strong alkalis and dehydrating media such as absolute ethanol. Do not assume compatibility from the stated pH range alone.
Use the physical controls for on-meter measurement and calibration. HOLD temporarily locks a reading on screen; write the result and its sample context in your external worksheet or record system. Screen values in photographs are illustrative, not sample results.
Use calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.
PH850 is a direct-reading Value-series instrument. Its current specification lists reading storage, storage content and output as N/A. Choose a separate recordkeeping method before starting a sample series; this meter does not supply stored-reading recall or a computer export workflow.
Optional automatic HOLD freezes a stable reading on the display. It helps with transcription but does not save the sample or create a timestamped entry. Record sample identity, pH, measured temperature, operator and your own date and time while the result is still associated with the correct vessel.
Retain buffer details, calibration checks and electrode-care observations alongside the sample result. For work governed by a quality procedure, use the organization’s approved worksheet and acceptance rules. The kit does not itself establish traceability, food safety, pharmaceutical release status or regulatory compliance.
Alternative format: Apera PH8500-BR Portable pH Meter Kit with LabSen 213 Electrode. The Premium Series counterpart offers a different recordkeeping workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.
The current US PH850-BR kit specifies LabSen 213, catalog AI3121. It combines pH and temperature sensing with BNC and RCA plugs. It is LabSen 213, not LabSen 223 or 211. Match the model and connections when ordering a replacement.
Use 3M KCl for both reference refill and external wet storage. LabSen 213’s current manual identifies AI1107 for the soaking solution. Refill when the reference level falls to about half height.
The model-specific manufacturer illustration lists the PH850, LabSen 213, carrying case, manual, screwdriver, pH 4.00/7.00/10.01 buffers and reference soaking solution, specified as 3M KCl by the probe manual. Exact bottle volumes and battery inclusion are not confirmed.
Suitable liquids may be measured within 0 to 100°C for this kit. Choose a consistent temperature for comparisons and handle hot samples carefully. Automatic compensation does not convert a beverage’s actual hot pH into its room-temperature chemistry.
The meter spans 0 to 14 pH with selectable 0.01 or 0.1 pH resolution and stated accuracy of ±0.01 pH ±1 digit. The supplied electrode also spans 0 to 14 pH. These specifications do not guarantee the same uncertainty in every sample or method.
No. HOLD only freezes the display. Reading memory and output are N/A for PH850, so write down the sample identity, pH, temperature and your own timestamp. No data-download workflow is included.
Confirm the supplied revision before purchasing replacements: the current US product page says three AA batteries, while the PH850 manual specifies three AAA. Battery inclusion is not established by those power specifications.
The current US page and PH850 manual specify a three-year limited instrument warranty and six months for the probe, from delivery. Coverage is for qualifying defects; accidental damage, misuse, normal wear, improper storage and other listed exclusions are not covered.
Review PH850-BR AI5533 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.
Apera Manufacturer Limited Warranty
Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.
Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.
Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; battery and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.