Refillable pH electrode for organic-solvent applications.
Preparing Quote Cart. Your shopping cart stays unchanged.
For LabSen 871 measurements in water-miscible solvents, use 1 M LiCl in ethanol to refill the outer reference chamber.
Swipe or use the arrows to browse.
APERA INSTRUMENTS / LABSEN 871 / AI3147
Measure pH in organic-solvent applications with the refillable Apera LabSen 871. Its robust PHY glass membrane, double-junction reference and movable sleeve support stable measurements in suitable non-aqueous samples. The electrode has a BNC connector and no built-in temperature sensor. Select the electrolyte and measurement procedure for your solvent class; water-immiscible samples use the prescribed water-extraction method.
Measurement range: pH 1–13. Electrode temperature range: 0–80°C. Use a compatible meter and temperature-compensation method within their respective limits. Manufacturer part number: AI3147.
Start with what makes your sample difficult. Published families link to their product pages. Other models are shown for comparison only; confirm the exact connector and host before choosing.
AI3141 / AI3153
Proteins, dairy, biotech
Protelyte electrolyte and triple ceramic junction.
AI3109 / AI3177 / AI3239
Strong acids, HF
HF-resistant glass; spot measurements below 0.1 mol/L HF.
AI3145 / AI3179 / AI3237
pH 12–14, salinity >0.5%
HA glass minimizes alkaline error; silver ion trap.
AI3110
Skincare, cosmetics, coatings
Conical membrane with Protelyte and triple ceramic junction.
AI3165
Coatings, syrups, resin, glue
Pre-pressurized gel KCl with low-impedance S membrane.
AI3168 / AI3180 / AI3243
Viscous, alkaline or salty
Pre-pressurized gel KCl and HA glass; BNC, BNC/RCA or 8-pin.
AI3167 / AI3176 / AI3241
Hot, caustic, electroplating
PHY glass and PTFE ring junction, rated to 130°C.
AI3147
Organic solvents
PHY glass, double junction with 1M LiCl outer bridge.
Connect the BNC plug to a compatible pH meter. LabSen 871 has no built-in temperature sensor; use a separate temperature probe supported by your meter or manual temperature entry where available. Observe the meter and temperature probe limits as well as the electrode’s 0–80°C rating.
LabSen’s most robust membrane, protecting the hydrated gel layer from organic solvents.
Outer movable-sleeve junction, nominally 1M LiCl; inner 3M KCl bridge; Ag/AgCl reference. Outer electrolyte selection is method-dependent, not universal for all solvents.
Specially formulated to prevent air bubbles and extend service life.
LabSen 871 has a lead-free glass body, PHY membrane, Ag/AgCl reference and refillable outer bridge with a movable-sleeve junction. The standard outer electrolyte is 1M LiCl; the inner bridge uses 3M KCl. Choose the outer electrolyte according to the measurement method.
The full specification table is in the Product Specifications tab.
Choose the method for your solvent. The full LabSen 871 manual specifies 1M LiCl outer electrolyte for water-miscible solvents. For water-immiscible solvents, it specifies 3M KCl outer electrolyte and measurement of the separated water extract. Follow the complete preparation and calibration procedure in the linked manual.
Never store the electrode in pure, deionized or distilled water.
Keep the refill opening unplugged during measurement. Follow the manual’s emptying and rinsing procedure when changing electrolyte. For storage longer than 24 hours after using 1M LiCl, empty that electrolyte and soak the tip in 3M KCl storage solution as directed.
Clean according to the sample and full manual. After solvent cleaning, rinse promptly with purified water, recondition in 3M KCl for at least one hour and recalibrate. Use a chemically compatible sample container; solvents such as toluene can attack polycarbonate. Follow the laboratory’s solvent handling and ventilation procedures.
Calibrate with fresh pH 7.00, pH 4.00 and pH 10.01 buffers.
Organic-solvent methods, with different workflows for water-miscible and water-immiscible samples. The full LabSen 871 manual uses 1M LiCl for miscible solvents, but 3M KCl plus a separated water-extract method for immiscible solvents; it does not prescribe a single direct-test LiCl workflow for all solvents.
Yes. Refill the outer bridge with the electrolyte required by your method: the full manual specifies 1M LiCl for water-miscible solvents and 3M KCl for the water-extract method used with water-immiscible solvents. Follow its emptying/rinsing procedure when switching; do not confuse the refill electrolyte with external storage solution.
For storage longer than 24 hours after using 1M LiCl, The LabSen 871 manual says to empty the LiCl outer electrolyte and soak the tip in 3M KCl storage solution. Follow the full emptying procedure and follow the full procedure. Never store it in pure, deionized or distilled water or leave it in the sample.
Apera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.
Do not assume so. For water-immiscible solvents, the full LabSen 871 manual prescribes 3M KCl outer electrolyte and measurement of a separated water extract. The result belongs to that extraction method, not an unqualified direct pH measurement of the neat solvent. Confirm the applicable procedure with Apera and your laboratory before testing.
No temperature sensor is built in. It uses BNC for the pH signal; automatic temperature compensation requires a separate probe supported by your meter. The electrode is rated 0–80°C, but the meter and any temperature probe may have narrower limits.
Use the solvent-specific procedure in the full 871 manual. A water rinse is suitable after water-miscible samples; immiscible residues may need a compatible solvent cleaner with ventilation. Rinse promptly with distilled/deionized water after solvent cleaning, recondition in 3M KCl for at least one hour and recalibrate.
No. The full LabSen 871 manual warns that solvents such as toluene can attack polycarbonate and recommends a compatible glass container that allows a sealed test. Check the sample-container materials and your laboratory method; the electrode’s glass body does not guarantee compatibility of every accessory.
Check the connector and catalog number (AI3147) against your meter and samples, then return to the live price and ordering controls.
The temperature range applies to the electrode. Observe host meter and temperature probe limits. Solvent-specific preparation, electrolyte changes and storage instructions are in the linked full manual.
APERA INSTRUMENTS, LLC warrants LabSen electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.
This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.
Contact Blue Tiger Scientific for product selection, manufacturer support or warranty assistance. Return eligibility is subject to our current return policy; contact us before returning an item.
Official LabSen 871 full user manual, English edition published by Apera Europe. Includes solvent-specific methods, electrolyte changes, cleaning and storage. Supplied accessories may vary by market; this manual is not an included-accessory list for this US listing.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.