Apera LabSen 871 Refillable Double-Junction pH Electrode for Organic Solvents and Non-Aqueous Solutions, BNC pH Electrode Apera Instruments
Apera LabSen 871 Refillable Double-Junction pH Electrode for Organic Solvents and Non-Aqueous Solutions, BNC pH Electrode Apera Instruments

Apera LabSen 871 Refillable Double-Junction pH Electrode for Organic Solvents and Non-Aqueous Solutions, BNC

$349.00

    Refillable pH electrode for organic-solvent applications.

    • PHY glass membrane; double junction with movable sleeve
    • pH 1–13; electrode temperature range 0–80°C
    • BNC connector; no built-in temperature sensor
    • Solvent-specific methods; immiscible samples require water extraction

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / LABSEN 871 / AI3147

pH in organic solvents
and non-aqueous samples.

Measure pH in organic-solvent applications with the refillable Apera LabSen 871. Its robust PHY glass membrane, double-junction reference and movable sleeve support stable measurements in suitable non-aqueous samples. The electrode has a BNC connector and no built-in temperature sensor. Select the electrolyte and measurement procedure for your solvent class; water-immiscible samples use the prescribed water-extraction method.

Measurement range: pH 1–13. Electrode temperature range: 0–80°C. Use a compatible meter and temperature-compensation method within their respective limits. Manufacturer part number: AI3147.

Apera LabSen 871 pH electrode
Apera LabSen 871.
Choose your LabSen electrode: demanding chemistryClick or tap to compare 8 electrode familiesCompare the models below - click or tap here to close

Check the connector.

Connect the BNC plug to a compatible pH meter. LabSen 871 has no built-in temperature sensor; use a separate temperature probe supported by your meter or manual temperature entry where available. Observe the meter and temperature probe limits as well as the electrode’s 0–80°C rating.

What makes it work.

PHY glass membrane

LabSen’s most robust membrane, protecting the hydrated gel layer from organic solvents.

Double junction, 1M LiCl

Outer movable-sleeve junction, nominally 1M LiCl; inner 3M KCl bridge; Ag/AgCl reference. Outer electrolyte selection is method-dependent, not universal for all solvents.

Blue gel inner electrolyte

Specially formulated to prevent air bubbles and extend service life.

Check the specifications.

LabSen 871 has a lead-free glass body, PHY membrane, Ag/AgCl reference and refillable outer bridge with a movable-sleeve junction. The standard outer electrolyte is 1M LiCl; the inner bridge uses 3M KCl. Choose the outer electrolyte according to the measurement method.

The full specification table is in the Product Specifications tab.

Store it wet.
Keep it clean.

Choose the method for your solvent. The full LabSen 871 manual specifies 1M LiCl outer electrolyte for water-miscible solvents. For water-immiscible solvents, it specifies 3M KCl outer electrolyte and measurement of the separated water extract. Follow the complete preparation and calibration procedure in the linked manual.

Never store the electrode in pure, deionized or distilled water.

Keep the refill opening unplugged during measurement. Follow the manual’s emptying and rinsing procedure when changing electrolyte. For storage longer than 24 hours after using 1M LiCl, empty that electrolyte and soak the tip in 3M KCl storage solution as directed.

Clean according to the sample and full manual. After solvent cleaning, rinse promptly with purified water, recondition in 3M KCl for at least one hour and recalibrate. Use a chemically compatible sample container; solvents such as toluene can attack polycarbonate. Follow the laboratory’s solvent handling and ventilation procedures.

Related items.

Calibrate with fresh pH 7.00, pH 4.00 and pH 10.01 buffers.

LabSen 871 buyer questions

What is the LabSen 871 made for?

Organic-solvent methods, with different workflows for water-miscible and water-immiscible samples. The full LabSen 871 manual uses 1M LiCl for miscible solvents, but 3M KCl plus a separated water-extract method for immiscible solvents; it does not prescribe a single direct-test LiCl workflow for all solvents.

Is it refillable?

Yes. Refill the outer bridge with the electrolyte required by your method: the full manual specifies 1M LiCl for water-miscible solvents and 3M KCl for the water-extract method used with water-immiscible solvents. Follow its emptying/rinsing procedure when switching; do not confuse the refill electrolyte with external storage solution.

How should I store it?

For storage longer than 24 hours after using 1M LiCl, The LabSen 871 manual says to empty the LiCl outer electrolyte and soak the tip in 3M KCl storage solution. Follow the full emptying procedure and follow the full procedure. Never store it in pure, deionized or distilled water or leave it in the sample.

What warranty applies?

Apera warrants LabSen electrodes against defects in material and workmanship for six months from delivery. Accidental damage, improper use and normal wear are excluded.

Can I measure neat toluene or hexane directly?

Do not assume so. For water-immiscible solvents, the full LabSen 871 manual prescribes 3M KCl outer electrolyte and measurement of a separated water extract. The result belongs to that extraction method, not an unqualified direct pH measurement of the neat solvent. Confirm the applicable procedure with Apera and your laboratory before testing.

Does LabSen 871 include temperature compensation?

No temperature sensor is built in. It uses BNC for the pH signal; automatic temperature compensation requires a separate probe supported by your meter. The electrode is rated 0–80°C, but the meter and any temperature probe may have narrower limits.

How do I clean solvent residues?

Use the solvent-specific procedure in the full 871 manual. A water rinse is suitable after water-miscible samples; immiscible residues may need a compatible solvent cleaner with ventilation. Rinse promptly with distilled/deionized water after solvent cleaning, recondition in 3M KCl for at least one hour and recalibrate.

Can I use the plastic vial with every solvent?

No. The full LabSen 871 manual warns that solvents such as toluene can attack polycarbonate and recommends a compatible glass container that allows a sealed test. Check the sample-container materials and your laboratory method; the electrode’s glass body does not guarantee compatibility of every accessory.

Confirm the exact configuration before ordering.

Check the connector and catalog number (AI3147) against your meter and samples, then return to the live price and ordering controls.

Back to price and ordering ↑
    SpecificationDetail
    ModelLabSen 871
    Manufacturer part numberAI3147
    pH range1–13
    Electrode temperature range0–80°C (32–176°F)
    Temperature sensorNone; separate host-compatible probe or manual temperature entry required
    HousingLead-free glass
    MembranePHY glass
    JunctionDouble junction with movable sleeve
    ReferenceAg/AgCl
    Standard outer-bridge electrolyte1M LiCl; select electrolyte according to the solvent method
    Inner-bridge electrolyte3M KCl
    RefillableYes
    ConnectorBNC
    Body dimensionsØ12 × 130 mm
    Cable length3 ft

    The temperature range applies to the electrode. Observe host meter and temperature probe limits. Solvent-specific preparation, electrolyte changes and storage instructions are in the linked full manual.

    Ordering Information

    Ordering detailConfiguration
    Blue Tiger SKUBTS-AI3147
    Order unit1 electrode

    Warranty Information

    APERA INSTRUMENTS, LLC warrants LabSen electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

    Contact Blue Tiger Scientific for product selection, manufacturer support or warranty assistance. Return eligibility is subject to our current return policy; contact us before returning an item.

    LabSen 871 documentation

    Official LabSen 871 full user manual, English edition published by Apera Europe. Includes solvent-specific methods, electrolyte changes, cleaning and storage. Supplied accessories may vary by market; this manual is not an included-accessory list for this US listing.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat