Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201-C – BNC combination pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201DJ-C – BNC double junction pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201T-S – 8-pin pH temperature pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201-C – BNC combination pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201DJ-C – BNC double junction pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S pH Electrode Apera Instruments
Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S 201T-S – 8-pin pH temperature pH Electrode Apera Instruments

Apera 201 Series PC-Body pH Electrode: 201-C, 201DJ-C or 201T-S

$36.00

    The everyday PC-body pH electrode.

    • General water pH
    • Versions: 201-C, 201DJ-C, 201T-S
    • Lithium glass membrane
    • Warranty: six months from delivery

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / 201-C · 201DJ-C · 201T-S / AI1301 / AI3115 / AI1312

The everyday PC-body
pH electrode.

Apera’s 201 series are economical polycarbonate-body pH electrodes for general pH measurement of water solutions in research, environmental monitoring and quality control. All three use Apera’s low-impedance lithium glass membrane and gel KCl electrolyte, so there is nothing to refill. The 201-C is a BNC combination electrode; the 201DJ-C adds a double junction for long-term testing in turbid water; the 201T-S is a 3-in-1 pH/temperature electrode with an 8-pin connector for Apera portable meters.

Choose the version from the menu above. Apera’s warranty: six months from delivery.

Apera 201 PC-Body pH
Apera 201-C · 201DJ-C · 201T-S.
Choose your Apera electrodeClick or tap to compare 6 electrode familiesCompare the models below - click or tap here to close

Pick the version
that fits your meter.

Version Key differences
201-C · AI1301 Connector: BNC; Temperature sensor: None; Junction: Single ceramic.
201DJ-C · AI3115 Connector: BNC; Temperature sensor: None; Junction: Double junction.
201T-S · AI1312 Connector: 8-pin; Temperature sensor: 30 kΩ thermistor (ATC); Junction: Single ceramic.

201-C and 201DJ-C fit pH meters with a BNC input. They have no built-in temperature sensor: use a separate sensor specifically supported by your meter or manual temperature entry. Apera explicitly lists PH400, PC400, PH400S and PC400S for the 8-pin 201T-S.

Apera 201-C
Apera 201-C.

What makes it work.

Lithium glass membrane

Apera’s proprietary low-impedance lithium glass for fast, stable readings in general water solutions.

Gel KCl, no refilling

A sealed gel reference keeps maintenance to rinsing and storage. A detachable cap keeps the sensor hydrated.

Double junction (201DJ-C)

Reduces junction clogs and extends service life for long-term testing in wastewater, pools, hydroponics and environmental monitoring.

Apera 201DJ-C
Apera 201DJ-C.

Check the specifications.

All three use Ag/AgCl references, gel KCl electrolyte and polycarbonate bodies measuring Ø12 × 160 mm. For all three models, the conservative current-US published measurement envelope is 0–13 pH and 0–60°C (32–140°F). The linked exact-model manuals publish broader 0–14 pH and 0–80°C limits; this listing uses only the narrower bounds supported by both sources, not a claim that every sample in that range is suitable. Broader limits depend on the supplied revision and are not offered here. Do not use for strong acids or bases, highly corrosive liquids, or prolonged/continuous hot-sample testing; retain the model-specific polycarbonate-body and connector precautions. The model-specific connector, temperature sensor and cable details are in the Product Specifications tab.

The full specification table, version by version, is in the Product Specifications tab.

Care and storage.

Keep the sensor wet in its cap with a little 3M KCl storage solution between uses, and never store it in pure, deionized or distilled water.

Rinse with distilled or deionized water between samples. For oily or sticky deposits, use Apera electrode cleaning solution, then re-soak and recalibrate.

Apera does not recommend these electrodes for low-ion solutions such as DI or distilled water, strong acids and strong bases (pH above 12), highly corrosive liquids, and continuous testing in high-temperature solutions.

Related items.

For a BNC/RCA pH/temperature configuration, use the separately listed 201T-F (AI1302), not the 8-pin 201T-S. Confirm the exact host meter before ordering.

For the BNC/RCA pH/temperature version used in the PH700, PH850 and PH8500 kits, see the 201T-F pH/temperature electrode (AI1302).

201 PC-Body pH buyer questions

Which 201 electrode matches a BNC pH meter?

201-C and 201DJ-C use BNC connectors. The 201T-S uses an 8-pin connector instead; it is not a BNC substitute.

What does the 201DJ-C add over the 201-C?

201DJ-C has a double junction designed to reduce clogging in turbid water, including wastewater and pool water. The 201-C has a single ceramic junction for general aqueous samples.

Does the 201-C measure temperature?

No. Neither 201-C nor 201DJ-C contains a temperature sensor. Use a separate temperature probe supported by your meter, or enter temperature manually if your meter allows it.

Which Apera meters are explicitly listed for 201T-S?

Apera lists PH400, PC400, PH400S and PC400S for the 201T-S. Its 8-pin plug carries pH and the signal from its 30 kΩ thermistor; connector appearance alone does not establish compatibility with other meters.

How large are the 201 electrodes, and how long is the cable?

The 201-C, 201DJ-C and 201T-S manuals specify a 12 mm diameter, 160 mm body length and 3 ft cable.

Can I use a 201 electrode for distilled water or strong chemicals?

These are general-water electrodes, not the first choice for low-ionic-strength DI or distilled water, strong acids or bases, or chemicals that attack polycarbonate. Choose an application-specific electrode for those samples.

Do I need to refill the electrolyte?

No. The 201-C, 201DJ-C and 201T-S use gel KCl reference electrolyte. Keep the sensing end in the specified KCl storage solution between uses; do not store it in pure water.

What should I do after fitting a replacement 201 electrode?

Keep the connector clean and dry, rinse the sensing end, and perform the three-point pH calibration specified in the electrode manual before relying on measurements.

Confirm the exact configuration before ordering.

Check the version and catalog number (AI1301 / AI3115 / AI1312) against your meter, then return to the live price and ordering controls.

Back to price and ordering ↑
    SpecificationDetail
    Model201-C / 201DJ-C / 201T-S
    Connector201-C: BNC; 201DJ-C: BNC; 201T-S: 8-pin
    Temperature sensor201-C: None; 201DJ-C: None; 201T-S: 30 kΩ thermistor (ATC)
    Junction201-C: Single ceramic; 201DJ-C: Double junction; 201T-S: Single ceramic
    ReferenceAg/AgCl, gel KCl (no refilling)
    BodyPolycarbonate
    DimensionsØ12 × 160 mm
    Cable201-C: 3 ft; 201DJ-C: 3 ft; 201T-S: 3 ft
    Manufacturer warrantySix months from delivery
    Conservative current-US measurement envelope201-C / 201DJ-C / 201T-S: 0–13 pH; 0–60°C (32–140°F)

    Operating scope and qualification: For all three models, the conservative current-US published measurement envelope is 0–13 pH and 0–60°C (32–140°F). The linked exact-model manuals publish broader 0–14 pH and 0–80°C limits; this listing uses only the narrower bounds supported by both sources, not a claim that every sample in that range is suitable. Broader limits depend on the supplied revision and are not offered here. Do not use for strong acids or bases, highly corrosive liquids, or prolonged/continuous hot-sample testing; retain the model-specific polycarbonate-body and connector precautions.

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI1301 / AI3115 / AI1312
    Blue Tiger SKUBTS-AI1301 / BTS-AI3115 / BTS-AI1312
    Versions201-C – BNC combination: AI1301; 201DJ-C – BNC double junction: AI3115; 201T-S – 8-pin pH/temperature: AI1312
    Order unit1 electrode

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this product to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

    201 PC-Body pH official documents

    Exact-model documents are identified below. Regional instruction sheets and host-tester manuals are labelled by scope; use the host manual for meter operation and calibration. Each whole card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat