Give us a call at (833)928-4437
Platinum-ring ORP electrodes for water and wastewater.
222 mV ORP standard is the catalogued check/calibration solution for this ORP head/electrode.
Swipe or use the arrows to browse.
APERA INSTRUMENTS / 301Pt-C · 301Pt-S / AI1303 · AI1315
Measure oxidation-reduction potential in general water solutions and wastewater with Apera’s 301Pt combination ORP electrodes. Both models use a platinum ring sensor, a ceramic junction and gel KCl electrolyte that requires no refilling. Choose 301Pt-C for an ORP-capable BNC meter or 301Pt-S for a compatible Apera 400/400S meter.
Select your connector above. The 301DJ-C option is currently unavailable; the specifications below apply to 301Pt-C and 301Pt-S.
Pick the measurement, then the connector your meter uses (BNC, BNC/RCA with temperature, or 8-pin) on that page. For application-specific pH electrodes, see the LabSen range.
201-C · 201DJ-C · 201T-S
General water pH
Economical PC-body pH electrode; BNC, double-junction or 8-pin.
301Pt-C · 301Pt-S
ORP / redox
Platinum ring ORP sensor; select BNC or compatible Apera 8-pin.
2301-C · 2301T-F · 2301T-S
Conductivity, K=1
POM body, platinum black sensor; BNC, BNC/RCA or 8-pin.
2401-C · 2401T-F
High-accuracy lab conductivity
Glass body, platinum chip in a cavity; BNC or BNC/RCA.
2310-C · 2310T-F
High range to 2,000 mS/cm
K=10 platinum black ring for brines and concentrates.
DJS-0.1-C · DJS-0.1-F
Pure and ultrapure water
K=0.1 with glass flow cell against airborne CO₂.
301Pt-C uses a standard BNC connection to an ORP-capable meter. The 301Pt-S 8-pin version is specified for Apera PH400, PC400, PH400S and PC400S meters. Check the model and measurement mode before ordering.
The platinum ring senses the sample’s oxidation-reduction potential for routine water and wastewater testing.
Ag/AgCl reference with gel KCl electrolyte keeps maintenance simple.
A ceramic junction connects the Ag/AgCl reference system to the sample in both 301Pt models.
Both 301Pt models have a polycarbonate body and platinum ring sensor. Their primary ordering difference is the connector: BNC on 301Pt-C and 8-pin on 301Pt-S.
See the Product Specifications tab for the confirmed 301Pt-C and 301Pt-S details.
Keep the sensing tip in the specified KCl storage solution and the connector clean and dry. Rinse between samples with purified water; do not use pure water for long-term storage. Protect the platinum ring from abrasion.
Check performance using the appropriate ORP standard and the procedure in the exact-model manual. ORP verification uses a redox standard rather than pH-buffer calibration.
Check the electrode against the appropriate ORP standard before use; select the connector and host meter according to the exact model documentation.
Check the electrode against Apera 222 mV ORP standard before measuring.
301Pt-C has a BNC connector; 301Pt-S has an 8-pin connector. Both use a platinum ring sensor, ceramic junction and non-refillable gel KCl reference electrolyte.
Use an ORP-capable meter with a compatible BNC input. A BNC pH input alone does not establish that a meter supports ORP measurement.
Apera lists PH400, PC400, PH400S and PC400S as compatible hosts for the 301Pt-S 8-pin electrode.
Apera specifies general water solutions and wastewater treatment. Choose the electrode and host meter for your sample and required ORP measurement range.
No. Both 301Pt-C and 301Pt-S use gel KCl electrolyte and do not require refilling.
Use an appropriate ORP standard and follow the exact-model electrode and meter instructions. ORP standard checks are different from pH-buffer calibration.
Keep the sensing tip in its specified KCl storage solution with the cap closed. Keep the connector dry, and do not use pure water as long-term storage solution.
Apera provides a six-month limited warranty from delivery against defects in material and workmanship. Exclusions and support information are in Additional Information.
Choose 301Pt-C (AI1303) for BNC or 301Pt-S (AI1315) for a compatible Apera 8-pin meter, then return to the price and ordering controls.
APERA INSTRUMENTS, LLC warrants 301Pt-C and 301Pt-S electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.
This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.
Contact Blue Tiger Scientific for product selection, manufacturer support or warranty assistance. Return eligibility is subject to our current return policy; contact us before returning an item.
Official English instruction sheets for 301Pt-C and 301Pt-S, published by Apera Europe. Use the matching electrode sheet together with your host meter manual. Select a card to open the PDF.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.