Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301Pt-C – BNC, platinum ring ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301Pt-S – 8-pin, platinum ring ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301DJ-C – BNC, double junction ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301Pt-C – BNC, platinum ring ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301Pt-S – 8-pin, platinum ring ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin 301DJ-C – BNC, double junction ORP Electrode Apera Instruments
Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin ORP Electrode Apera Instruments

Apera 301 Series ORP Electrodes: 301Pt-C BNC or 301Pt-S 8-Pin

$98.00

    Platinum-ring ORP electrodes for water and wastewater.

    • 301Pt-C: BNC connector · AI1303
    • 301Pt-S: 8-pin for compatible Apera 400/400S meters · AI1315
    • Gel KCl electrolyte; no refilling required
    • Polycarbonate body and ceramic junction

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

APERA INSTRUMENTS / 301Pt-C · 301Pt-S / AI1303 · AI1315

A platinum ORP electrode
for water and wastewater.

Measure oxidation-reduction potential in general water solutions and wastewater with Apera’s 301Pt combination ORP electrodes. Both models use a platinum ring sensor, a ceramic junction and gel KCl electrolyte that requires no refilling. Choose 301Pt-C for an ORP-capable BNC meter or 301Pt-S for a compatible Apera 400/400S meter.

Select your connector above. The 301DJ-C option is currently unavailable; the specifications below apply to 301Pt-C and 301Pt-S.

Apera 301 ORP
Apera 301Pt-C ORP combination electrode.
Choose your Apera electrodeClick or tap to compare 6 electrode familiesCompare the models below - click or tap here to close

Pick the version
that fits your meter.

Version Key differences
301Pt-C · AI1303 Connector: BNC; Sensor: Platinum ring; Junction: Single ceramic.
301Pt-S · AI1315 Connector: 8-pin; Sensor: Platinum ring; Junction: Single ceramic.

301Pt-C uses a standard BNC connection to an ORP-capable meter. The 301Pt-S 8-pin version is specified for Apera PH400, PC400, PH400S and PC400S meters. Check the model and measurement mode before ordering.

Apera 301Pt-C
Apera 301Pt-C.

What makes it work.

Platinum sensor

The platinum ring senses the sample’s oxidation-reduction potential for routine water and wastewater testing.

Gel KCl, no refilling

Ag/AgCl reference with gel KCl electrolyte keeps maintenance simple.

Ceramic junction

A ceramic junction connects the Ag/AgCl reference system to the sample in both 301Pt models.

Apera 301Pt-S
Apera 301Pt-S.

Check the specifications.

Both 301Pt models have a polycarbonate body and platinum ring sensor. Their primary ordering difference is the connector: BNC on 301Pt-C and 8-pin on 301Pt-S.

See the Product Specifications tab for the confirmed 301Pt-C and 301Pt-S details.

Care and storage.

Keep the sensing tip in the specified KCl storage solution and the connector clean and dry. Rinse between samples with purified water; do not use pure water for long-term storage. Protect the platinum ring from abrasion.

Check performance using the appropriate ORP standard and the procedure in the exact-model manual. ORP verification uses a redox standard rather than pH-buffer calibration.

Related items.

Check the electrode against the appropriate ORP standard before use; select the connector and host meter according to the exact model documentation.

Check the electrode against Apera 222 mV ORP standard before measuring.

301 ORP buyer questions

What is the difference between 301Pt-C and 301Pt-S?

301Pt-C has a BNC connector; 301Pt-S has an 8-pin connector. Both use a platinum ring sensor, ceramic junction and non-refillable gel KCl reference electrolyte.

Which meters work with 301Pt-C?

Use an ORP-capable meter with a compatible BNC input. A BNC pH input alone does not establish that a meter supports ORP measurement.

Which meters work with 301Pt-S?

Apera lists PH400, PC400, PH400S and PC400S as compatible hosts for the 301Pt-S 8-pin electrode.

What samples are these electrodes designed for?

Apera specifies general water solutions and wastewater treatment. Choose the electrode and host meter for your sample and required ORP measurement range.

Do these electrodes require electrolyte refilling?

No. Both 301Pt-C and 301Pt-S use gel KCl electrolyte and do not require refilling.

How do I check ORP performance?

Use an appropriate ORP standard and follow the exact-model electrode and meter instructions. ORP standard checks are different from pH-buffer calibration.

How should I store the electrode?

Keep the sensing tip in its specified KCl storage solution with the cap closed. Keep the connector dry, and do not use pure water as long-term storage solution.

What warranty applies to 301Pt-C and 301Pt-S?

Apera provides a six-month limited warranty from delivery against defects in material and workmanship. Exclusions and support information are in Additional Information.

Confirm the exact configuration before ordering.

Choose 301Pt-C (AI1303) for BNC or 301Pt-S (AI1315) for a compatible Apera 8-pin meter, then return to the price and ordering controls.

Back to price and ordering ↑
    SpecificationDetail
    Models301Pt-C / 301Pt-S
    Manufacturer part numbers301Pt-C: AI1303; 301Pt-S: AI1315
    MeasurementOxidation-reduction potential (ORP / redox)
    Connector301Pt-C: BNC; 301Pt-S: 8-pin
    SensorPlatinum ring
    JunctionCeramic
    ReferenceAg/AgCl
    Reference electrolyteGel KCl; no refilling required
    HousingPolycarbonate
    Body dimensionsØ12 × 160 mm (both models)
    Meter compatibility301Pt-C: compatible ORP-capable BNC input; 301Pt-S: Apera PH400, PC400, PH400S and PC400S

    Ordering Information

    Ordering detailConfiguration
    Blue Tiger SKUBTS-AI1303 / BTS-AI1315
    Order unit1 selected electrode
    301DJ-C optionCurrently unavailable

    Warranty Information

    APERA INSTRUMENTS, LLC warrants 301Pt-C and 301Pt-S electrodes to be free from defects in material and workmanship for SIX MONTHS from the delivery.

    This limited warranty does NOT cover accidental damage, improper use, normal wear and tear, transportation, storage, failure to follow the product instructions, unauthorized maintenance, modification or repair, or external causes beyond Apera's reasonable control.

    Contact Blue Tiger Scientific for product selection, manufacturer support or warranty assistance. Return eligibility is subject to our current return policy; contact us before returning an item.

    301 ORP official documents

    Official English instruction sheets for 301Pt-C and 301Pt-S, published by Apera Europe. Use the matching electrode sheet together with your host meter manual. Select a card to open the PDF.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat