$754.99

    Optimize your boiler and cooling tower operations with the Hanna Instruments HI83305-01, a compact, multiparameter photometer designed for precise water quality testing in both lab and field environments. This advanced instrument accurately measures 18 key parameters, including critical oxygen scavengers and silica, ensuring system integrity and preventing costly damage.

    Comprehensive Water Analysis: Measures 18 essential water quality parameters for boiler and cooling tower systems.

    Dual Functionality: Acts as both a precise photometer and a professional digital pH meter, saving valuable bench space.

    Superior Accuracy: Features an innovative optical system for error-free, reliable results every time.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Overview: The Hanna Instruments HI83305 benchtop photometer is expertly engineered for comprehensive water quality analysis in boiler and cooling tower applications. Featuring an innovative optical system with LEDs, narrow band interference filters, and a focusing lens, it utilizes both an absorbance photodetector and a reference detector to ensure highly accurate and repeatable measurements for all 18 key water parameters across 30 distinct methods.

Maintaining optimal water conditions in boilers and cooling towers is crucial for preventing costly issues like corrosion, deposition, and microbial growth. This advanced instrument is specifically designed to monitor critical parameters such as oxygen scavengers and silica, ensuring system efficiency and longevity. The inclusion of a digital pH electrode input further enhances its versatility, allowing for precise pH measurements with automatic temperature compensation and smart probe recognition, eliminating the need for frequent recalibrations.

Beyond routine testing, the HI83305 offers a powerful absorbance measuring mode, enabling users to perform CAL Check™ validations and develop custom concentration curves across five selectable wavelengths (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm). With dual USB ports for seamless data transfer to flash drives or computers, and an internal rechargeable Li-polymer battery for extended field use, this photometer delivers both robust performance and convenient portability.

Note: Reagents are not included with the meter and can be purchased here.

IDEAL APPLICATIONS: Boiler Water Treatment, Cooling Tower Management, Industrial Water Quality Control, HVAC System Maintenance, Chemical Processing, Power Generation.

On-Screen Features

Method Selection

Method Selection

Effortlessly choose from 30 pre-programmed measurement methods using the intuitive dedicated METHOD button for simplified setup.

Data Logging

Data Logging

Store up to 1000 photometric and pH readings with optional user and sample IDs, easily accessible for complete data traceability.

pH Measurement Mode

pH Measurement Mode

Utilize the photometer as a professional pH meter, complete with temperature-compensated measurements, two-point auto calibration, and GLP tracking.

Key Features:

  • Digital pH Electrode Input: Seamlessly measure pH and temperature with a single digital probe that stores calibration data for hot-swapping.
  • Powerful Data Logging: Log up to 1000 photometric and pH readings with optional alphanumeric sample and user IDs for comprehensive record-keeping.
  • Versatile Connectivity: Transfer logged data quickly via USB-A to a flash drive or micro USB-B to a computer for easy analysis in .CSV format.
  • Intuitive Display & Feedback: Features a backlit 128 x 64 pixel graphic LCD for clear viewing, on-screen help, battery status, and diagnostic error messages for photometric and pH issues.
  • Built-in Reaction Timer: Ensures consistent and accurate photometric measurements by automatically initiating readings after the countdown timer expires.
  • Absorbance Measurement Mode: Use CAL Check™ cuvettes to validate system performance or develop custom concentration versus absorbance curves at five selectable wavelengths.

Key Benefits:

  • Enhanced Accuracy: Innovative optical system with a reference detector and focusing lens virtually eliminates errors from light source variations and cuvette imperfections.
  • Optimized System Performance: Crucial for boiler and cooling tower applications, preventing corrosion, scaling, and microbial growth by precisely monitoring key parameters.
  • Space-Saving Design: Combines a multiparameter photometer and a professional pH meter into one compact benchtop unit.
  • Educational & Research Ready: Supports advanced photometric principles like the Beer-Lambert Law, ideal for developing custom methods or educational purposes.
  • Increased Efficiency: Digital pH electrode hot-swapping saves calibration time, while automated features streamline testing procedures.
  • Field & Lab Versatility: Operates on an internal rechargeable battery for portability and includes USB connectivity for both power and data transfer.

Advanced Optical System

Innovative Design

The HI83305 features an innovative optical system incorporating a beam splitter. This design allows light to be directed for absorbance readings and to a dedicated reference detector, ensuring unparalleled performance and consistency.

High Efficiency LED Light Source

LEDs offer superior performance over traditional tungsten lamps, providing higher luminous efficiency, lower heat output, and consistent light across a wide array of wavelengths, including challenging blue/violet light.

High-Quality Narrow Band Interference Filters

Our highly efficient narrow band interference filters guarantee ±1 nm wavelength accuracy and allow up to 95% light transmission, resulting in a brighter, stronger light source, improved measurement stability, and reduced error.

Reference Detector for Stable Light Source

An internal reference detector within the HI83305's optical system continually monitors light intensity, compensating for drift caused by power fluctuations or ambient temperature changes, ensuring a stable light source for all measurements.

Large Cuvette Size

The HI83305 accommodates a round, glass cuvette with a 25 mm path length. This larger size, combined with advanced optical components, significantly minimizes rotation errors and allows for accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

A strategically placed focusing lens in the optical path collects all light exiting the cuvette and directs it precisely onto the silicon photodetector. This innovative approach effectively cancels out errors from cuvette imperfections, eliminating the need for cuvette indexing.

Parameters

Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code
Absorbance 0.000 to 4.000 Abs 0.001 Abs ±0.003Abs @ 1.000 Abs      
Aluminum 0.00 to 1.00 mg/L (as Al3+) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the aluminon method. 525 nm HI93712-01
Ammonia, Low Range 0.00 to 3.00 mg/L (as NH3-N) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. 420 nm HI93700-01
Ammonia, Medium Range 0.00 to10.00 mg/L (as NH3-N) 0.01 mg/L ±0.05 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93715-01
Ammonia, High Range 0.0 to 100.0 mg/L (as NH3-N) 0.1 mg/L ±0.5 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93733-01
Bromine 0.00 to 8.00 mg/L (as Br2) 0.01 mg/L ±0.08 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method 525 nm HI93716-01
Chlorine Dioxide 0.00 to 2.00 mg/L (as ClO2) 0.01 mg/L ±0.10 mg/L ±5% of reading Adaptation of the Chlorophenol Red method 575 nm HI93738-01
Chlorine Dioxide, Rapid Method 0.00 to 2.00 mg/L (as ClO2) 0.01 mg/L ±0.10 mg/L ±5% of reading Adapted from Standard Methods for the Examination of Water and Wastewater,18 ed., 4500 ClO2 D. 525 nm HI96779-01
Chlorine, Free 0.00 to 5.00 mg/L (as Cl2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93701-01
Chlorine, Total 0.00 to 5.00 mg/L (as Cl2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93711-01
Chromium (VI), Low Range 0 to 300 µg/L (as Cr(VI)) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method 525 nm HI93749-01
Chromium (VI), High Range 0 to 1000 µg/L (as Cr(VI)) 1 µg/L ±5 µg/L ±4% of reading at 25 °C Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method 525 nm HI93723-01
Copper, Low Range 0.000 to 1.500 mg/L (as Cu) 0.001 mg/L ±0.010 mg/L ±5% of reading Adaptation of the EPA method 575 nm HI95747-01
Copper, High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading Adaptation of the EPA method 575 nm HI93702-01
Hydrazine 0 to 400 µg/L (as N2H4) 1 µg/L ±4% of full scale reading Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminaminobenzaldehyde method 466 nm HI93704-01
Iron, Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading Adaptation of the TPTZ Method 575 nm HI93746-01
Iron, High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters 525 nm HI93721-01
Iron (II) - Ferrous 0.00 to 6.00 mg/L Fe2+) 0.01 mg/L ±0.10 mg/L ±2% of reading Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method 525 nm HI96776-01
Molybdenum 0.0 to 40.0 mg/L (as Mo6+) 0.1 mg/L ±0.3 mg/L ±5% of reading Adaptation of the mercaptoacetic acid method 420 nm HI93730-01
Nitrate 0.0 to 30.0 mg/L (as NO3-N) 0.1 mg/L ±0.5 mg/L ±10% of reading Adaptation of the cadmium reduction method 525 nm HI93728-01
Nitrite, Low Range 0 to 600 µg/L (as NO2-N) 1 µg/L ±20 µg/L ±4% of reading Adaptation of the EPA Diazotization method 354.1 466 nm HI93707-01
Nitrite, High Range 0 to 150 mg/L (as NO2-) 1 mg/L ±4 mg/L ±4% of reading Adaptation of the Ferrous Sulfate method 575 nm HI93708-01
Oxygen, Dissolved 0.0 to 10.0 mg/L (as O2) 0.1 mg/L ±0.4 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method 420 nm HI93732-01
Oxygen Scavengers (Carbohydrazide) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.01 mg/L ±0.02 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01
Oxygen Scavengers (Diethylhydroxylamine)(DEHA) 0 to 1000 µg/L (as DEHA) 1 µg/L ±5 µg/L ±5% of reading Adaptation of the iron reduction method 575 nm HI96773-01
Oxygen Scavengers (Hydroquinone) 0.00 to 2.50 mg/L (as Hydroquinone) 0.01 mg/L ±0.04 mg/L ±3% of reading Adaptation of the iron reduction method 575 nm HI96773-01
Oxygen Scavengers (Iso-ascorbic Acid) 0.00 to 4.50 mg/L (as Iso-ascorbic acid) 0.01 mg/L ±0.03 mg/L ±3 % of reading Adaptation of the iron reduction method 575 nm HI96773-01
pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Adaptation of the Phenol Red method 525 nm HI93710-01
Phosphate, Low Range 0.00 to 2.50 mg/L (as PO43-) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the Ascorbic Acid method 610 nm HI93713-01
Phosphate, High Range 0.0 to 30.0 mg/L(as PO43-) 0.1 mg/L ±1.0 mg/L ±4% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method 525 nm HI93717-01
Silica, Low Range 0.00 to 2.00 mg/L (as SiO2) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method 610 nm HI93705-01
Silica, High Range 0 to 200 mg/L (as SiO2) 1 mg/L ±1 mg/L ±5% of reading Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and Standard Method 4500-SiO2 466 nm HI96770-01
Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method 575 nm HI93731-01
    Specification Detail
    sku HI83305-01
    Wavelength Accuracy ±1 nm
    Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
    Spectral bandwidth 8 nm
    Input Channels 1 pH electrode input and 5 photometer wavelengths
    pH Electrode digital pH electrode (not included)
    Logging Type log on demand with user name and sample ID optional input
    Logging Memory 1000 readings
    Connectivity USB-A host for flash drive micro-USB-B for power and computer connectivity
    GLP calibration data for connected pH electrode
    Display 128 x 64 pixel LCD with backlight
    Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
    Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment 0 to 50.0 °C (32 to 122.0 °F) 0 to 95% RH, non-condensing
    Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)
    Weight 1.0 kg (2.2 lbs.)
    Photometer/Colorimeter Light Detector silicon photodetector
    Cuvette Type round, 24.6 mm
    Number of Methods 128 max.
    Ordering Information Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
    Warranty 2 years
    Note *Reagents are not included.

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI83305-01 Boiler & Cooling Tower Photometer Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)