Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93731 Zinc Reagents, 100 or 300 Tests Photometer Reagents Hanna Instruments
Hanna HI93731 Zinc Reagents, 100 or 300 Tests Photometer Reagents Hanna Instruments

Hanna HI93731 Zinc Reagents, 100 or 300 Tests

$87.99

    A zinc refill is more than a powder packet. Replenish HI97731 water-sample testing with the complete matched powder/liquid reagent set.

    • HI93731-01: 100 tests; HI93731-03: 300 tests
    • HI97731: 0.00 to 3.00 mg/L as Zn
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI93731

A zinc refill is more than a powder packet.

Plan for both parts of the HI97731 zinc procedure. These complete reagent sets pair powder reagent A with liquid reagent B, so the replenishment matches the actual method rather than the generic packet image alone.

Choose HI93731-01 for 100 tests or HI93731-03 for 300 tests. Pack size changes your test supply, not the method or measurement range.

Official Hanna HI93731 reagent reference image
Official Hanna generic reagent image; the zinc set also uses liquid reagent B. Printed expiration dates are illustrative, not the dates of supplied stock.

Check the meter, method and reporting basis

Primary reference: HI97731 — 0.00 to 3.00 mg/L as Zn. Both packs are also documented for HI83300, HI83305, HI83306, HI83308, HI83399. Select the matching method in your exact instrument manual; do not assume every Hanna photometer uses these reagents.

What the chemistry measures

The Zincon colorimetric chemistry changes the sample response from brownish-green toward blue. The HI97731 measures that response as zinc in water samples over 0.00 to 3.00 mg/L as Zn. Its instruction manual identifies the 18th-edition Standard Methods adaptation; the current reagent-page description cites the 20th edition. Follow the procedure for your exact instrument.

What arrives — and what stays separate

The complete set supplies HI93731A-0 powder and HI93731B-0 liquid for the selected test count. It is not a powder-only refill; the manufacturer photograph is generic reagent artwork, not a complete contents photograph.

The photometer, cuvettes, stoppers, caps, graduated sample-preparation glassware and dispensing accessories are not included. CAL Check standards are separate instrument-verification products, not reagents for reacting with a water sample.

The HI97731 workflow at a glance

Measure 20 mL of sample in a graduated glass vial. Add one packet of HI93731A-0, close and invert until the powder dissolves. Transfer 10 mL of that mixture to a cuvette, fit the stopper and cap, align it and zero the HI97731. Remove the cuvette, add 0.5 mL of HI93731B-0, close and swirl gently for 15 seconds. Return it to the meter and use the 3-minute 30-second Read countdown.

Use the linked method manual for the full procedure and temperature guidance. Keep cuvette exteriors clean and dry, avoid bubbles and maintain the specified alignment in the holder.

Water samples: check the matrix before relying on a result

The HI97731 manual lists potential interference from iron above 7 mg/L, aluminum above 6 mg/L, copper, manganese or nickel above 5 mg/L, and cadmium above 0.5 mg/L.

This is not a universal seawater, brine or high-interference-matrix claim. Confirm the sample composition against the exact instrument method before testing; a larger pack does not overcome an interference.

Choose a test supply you can use

HI93731-01 is the 100-test refill; HI93731-03 is the 300-test refill for a larger sampling workload. Each order quantity is one complete selected pack, not one test. Check the lot and expiration markings on the supplied packets and bottles and plan consumption accordingly.

Handling and shipping

The US SDS identifies potassium cyanide among the ingredients in reagent A and identifies reagent B as cyclohexanone, a flammable liquid. Reagent A must not contact acids, which can release very toxic gas. Review both SDS for suitable ventilation, protective equipment, incompatibilities and waste handling. Keep reagent B away from heat, sparks and flames.

Hanna classifies these packs as Dangerous Goods for ground shipment only. Review the component SDS before ordering and using the set; the brief workflow above is not a substitute for the complete safety documents.

Frequently Asked Questions

Should I choose the 100- or 300-test pack?

HI93731-01 supplies reagent for 100 tests; HI93731-03 supplies reagent for 300 tests. Choose by expected workload and marked expiration dates. Both are complete method reagent sets, and neither changes the analytical range.

Is this a powder-only zinc test?

No. The HI97731 method needs HI93731A-0 powder and HI93731B-0 liquid. One determination uses one packet of A and 0.5 mL of B. The generic manufacturer packet photograph does not show every supplied component.

When do I zero the HI97731?

Prepare 20 mL of sample with one packet of A, then transfer 10 mL of that mixture to a cuvette and zero the instrument. Add 0.5 mL of B only after zeroing. Zeroing untreated sample instead would change the documented procedure.

How long do I mix and wait after reagent B?

Swirl gently for 15 seconds after adding B, then use the HI97731 3-minute 30-second measurement countdown. Follow the complete manual for preparation, cuvette alignment and temperature guidance.

What handling checks matter for this formulation?

Reagent A contains potassium cyanide; contact with acids can release very toxic gas. Reagent B is cyclohexanone and is flammable. Read both linked US SDS and use their specified ventilation, protection, storage and disposal controls. This is not a harmless single-packet substitute.

Which instruments are documented for HI93731?

Both packs are documented for HI83300, HI83305, HI83306, HI83308, HI83399, HI97731. The procedure and range summarized here are for HI97731; use the matching method and full manual for another named instrument.

Can I use it in any water matrix?

The HI97731 manual lists potential interference from iron above 7 mg/L, aluminum above 6 mg/L, copper, manganese or nickel above 5 mg/L, and cadmium above 0.5 mg/L. Validate the matrix against the method rather than assuming seawater or brine compatibility.

Does my order include the meter, cuvettes or standards?

No. This is a complete reagent set only, in the selected 100- or 300-test size. Supply the compatible meter, cuvettes with stoppers and caps, preparation and dispensing accessories separately. CAL Check standards are also separate and cannot replace sample reagents.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterZinc
    Catalog numbersHI93731-01; HI93731-03
    Reagent formatMixed powder/liquid set: HI93731A-0 powder and HI93731B-0 liquid
    MethodHI97731: adaptation of Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
    Reference instrumentHI97731
    Range and units on HI977310.00 to 3.00 mg/L as Zn
    Other documented modelsHI83300, HI83305, HI83306, HI83308, HI83399
    Reagent doseOne packet of A plus 0.5 mL of B per determination
    Sample preparation20 mL sample reacted with A; transfer 10 mL to the cuvette before adding B
    MixingDissolve A by inversion; after adding B, swirl gently for 15 seconds
    Read countdown3 minutes 30 seconds
    Sample matrixWater samples within exact-method interference limits; no universal seawater claim
    Interference boundariesThe HI97731 manual lists potential interference from iron above 7 mg/L, aluminum above 6 mg/L, copper, manganese or nickel above 5 mg/L, and cadmium above 0.5 mg/L.
    Supplied itemComplete reagent set only; instrument, glassware and CAL Check standards separate
    Shipping limitationDangerous Goods; ground shipment only

    Ordering Information

    SpecificationDetail
    HI93731-01100 tests — complete A powder/B liquid set
    HI93731-03300 tests — complete A powder/B liquid set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.