Hanna HI93730 Molybdenum Reagents, 100 or 300 Tests Photometer Reagents Hanna Instruments
Hanna HI93730 Molybdenum Reagents, 100 or 300 Tests Photometer Reagents Hanna Instruments

Hanna HI93730 Molybdenum Reagents, 100 or 300 Tests

$137.49

    Three reagents. One matched molybdenum method. Replenish HI97730 water-sample testing with the complete matched three-powder reagent set.

    • HI93730-01: 100 tests; HI93730-03: 300 tests
    • HI97730: 0.0 to 40.0 mg/L as Mo⁶⁺
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI93730

Three reagents. One matched molybdenum method.

Keep the A, B and C chemistry together when replenishing your HI97730. These reagent-only packs support molybdenum measurements in water samples without requiring you to prepare the method reagents from bulk chemicals.

Choose HI93730-01 for 100 tests or HI93730-03 for 300 tests. Pack size changes your test supply, not the method or measurement range.

Official Hanna HI93730 reagent reference image
Manufacturer reference packaging. Printed lot and expiration dates are illustrative, not the dates of supplied stock.

Check the meter, method and reporting basis

Primary reference: HI97730 — 0.0 to 40.0 mg/L as Mo⁶⁺. Both packs are also documented for HI83300, HI83305, HI83306, HI83308, HI83399. Select the matching method in your exact instrument manual; do not assume every Hanna photometer uses these reagents.

What the chemistry measures

The mercaptoacetic acid method develops a yellow response that the compatible photometer measures. The HI97730 reports molybdenum as Mo⁶⁺; its Chemical Form function can convert the display to molybdate (MoO₄²⁻) or sodium molybdate (Na₂MoO₄). Those converted forms should not be mistaken for the primary molybdenum range.

What arrives — and what stays separate

The selected complete reagent set supplies A, B and C chemistry for the stated test count; it is not a pack of a single component.

The photometer, cuvettes, stoppers, caps, graduated sample-preparation glassware and dispensing accessories are not included. CAL Check standards are separate instrument-verification products, not reagents for reacting with a water sample.

The HI97730 workflow at a glance

Zero the HI97730 using 10 mL of unreacted sample in a clean, capped cuvette. In a graduated mixing cylinder, measure 25 mL of sample. Add one packet of HI93730A-0 and invert until dissolved; repeat with one packet of HI93730B-0. Add one packet of HI93730C-0 and shake vigorously. Transfer 10 mL of the reacted sample to an empty cuvette, stopper and cap it, align it in the meter and use the 5-minute Read countdown.

Use the linked method manual for the full procedure and temperature guidance. Keep cuvette exteriors clean and dry, avoid bubbles and maintain the specified alignment in the holder.

Water samples: check the matrix before relying on a result

Nitrite must be absent. The HI97730 manual lists potential interference from chromium above 1000 mg/L, sulfate above 200 mg/L, aluminum, iron or nickel above 50 mg/L, and copper above 10 mg/L. Strongly buffered samples or extreme pH can exceed the reagent buffering capacity.

This is not a universal seawater, brine or high-interference-matrix claim. Confirm the sample composition against the exact instrument method before testing; a larger pack does not overcome an interference.

Choose a test supply you can use

HI93730-01 is the 100-test refill; HI93730-03 is the 300-test refill for a larger sampling workload. Each order quantity is one complete selected pack, not one test. Check the lot and expiration markings on the supplied packets and plan consumption accordingly.

Handling and shipping

Read all three US SDS before use: the components have different hazards, including an oxidizing reagent B. Use the protection, storage segregation and disposal procedures specified for each component. Avoid dust exposure and keep the reagents away from incompatible materials.

Hanna classifies these packs as Dangerous Goods for ground shipment only. Review the component SDS before ordering and using the set; the brief workflow above is not a substitute for the complete safety documents.

Frequently Asked Questions

Should I choose the 100- or 300-test pack?

HI93730-01 supplies reagent for 100 tests; HI93730-03 supplies reagent for 300 tests. Choose by expected workload and marked expiration dates. Both are complete method reagent sets, and neither changes the analytical range.

Do I need all three molybdenum components?

Yes. The HI97730 procedure calls for one packet each of HI93730A-0, HI93730B-0 and HI93730C-0 per determination. These are complete reagent-set options, not individual A-, B- or C-only refills.

Is the displayed result molybdenum or molybdate?

The primary HI97730 range is 0.0 to 40.0 mg/L as molybdenum (Mo⁶⁺). Chemical Form can convert to molybdate or sodium molybdate. Match the reporting basis required by your sampling program; the converted display is not the same numeric scale.

Why does the procedure need a mixing cylinder?

The reaction is prepared in 25 mL of sample in a graduated mixing cylinder, while the cuvette reading uses 10 mL. Zero with a separate 10 mL portion of unreacted sample. Do not add the three packets directly to a 10 mL sample and assume the method is unchanged.

How do the additions and countdown work?

Dissolve A by inversion, then dissolve B by inversion. Add C and shake vigorously. Read 10 mL of reacted sample using the HI97730 5-minute countdown. The manual gives temperature guidance and the complete measurement sequence.

Which instruments are documented for HI93730?

Both packs are documented for HI83300, HI83305, HI83306, HI83308, HI83399, HI97730. The procedure and range summarized here are for HI97730; use the matching method and full manual for another named instrument.

Can I use it in any water matrix?

Nitrite must be absent. The HI97730 manual lists potential interference from chromium above 1000 mg/L, sulfate above 200 mg/L, aluminum, iron or nickel above 50 mg/L, and copper above 10 mg/L. Strongly buffered samples or extreme pH can exceed the reagent buffering capacity. Validate the matrix against the method rather than assuming seawater or brine compatibility.

Does my order include the meter, cuvettes or standards?

No. This is a complete reagent set only, in the selected 100- or 300-test size. Supply the compatible meter, cuvettes with stoppers and caps, preparation and dispensing accessories separately. CAL Check standards are also separate and cannot replace sample reagents.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterMolybdenum
    Catalog numbersHI93730-01; HI93730-03
    Reagent formatThree-component powder set: HI93730A-0, HI93730B-0 and HI93730C-0
    MethodAdaptation of the mercaptoacetic acid method
    Reference instrumentHI97730
    Range and units on HI977300.0 to 40.0 mg/L as Mo⁶⁺
    Other documented modelsHI83300, HI83305, HI83306, HI83308, HI83399
    Reagent doseOne packet each of A, B and C per determination
    Sample preparation10 mL unreacted sample for zero; 25 mL for reaction; 10 mL reacted sample for reading
    MixingDissolve A, then B by inversion; add C and shake vigorously
    Read countdown5 minutes
    Sample matrixWater samples within exact-method interference limits; no universal seawater claim
    Interference boundariesNitrite must be absent. The HI97730 manual lists potential interference from chromium above 1000 mg/L, sulfate above 200 mg/L, aluminum, iron or nickel above 50 mg/L, and copper above 10 mg/L. Strongly buffered samples or extreme pH can exceed the reagent buffering capacity.
    Supplied itemComplete reagent set only; instrument, glassware and CAL Check standards separate
    Shipping limitationDangerous Goods; ground shipment only

    Ordering Information

    SpecificationDetail
    HI93730-01100 tests — complete A/B/C powder set
    HI93730-03300 tests — complete A/B/C powder set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.