Apera PC800 Benchtop pH/Conductivity Meter Kit Default Title Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PH800 Laboratory Benchtop pH Meter Kit | AI521 Benchtop pH Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Default Title Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PH800 Laboratory Benchtop pH Meter Kit | AI521 Benchtop pH Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments
Apera PC800 Benchtop pH/Conductivity Meter Kit Benchtop pH and Conductivity Meter Apera Instruments

Apera PC800 Benchtop pH/Conductivity Meter Kit

$699.00

    Separate pH and conductivity electrodes, guided calibration and mode-specific stored results.

    • 201T-F pH/temperature and separate 2301T-F conductivity/temperature probes
    • 0.01 pH resolution; ±0.01 pH ±1 digit meter accuracy
    • 1 to 3 pH calibration points; 1 to 4 conductivity points
    • 1000 mode-specific records; USB output and timed storage

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PC800 / AI523

Two measurement modes.
One organized water-testing bench.

PC800 brings pH and conductivity testing into one benchtop instrument without combining their sensing chemistry. The current AI523 kit supplies a 201T-F pH/temperature electrode and a separate 2301T-F conductivity/temperature electrode, plus a flexible holder and six calibration solutions.

Choose PC800 for routine aqueous measurements where 0.01 pH resolution, conductivity up to 200 mS/cm and timestamped storage fit the method. It measures either pH or conductivity with temperature, not both primary parameters simultaneously. The supplied probes, rather than the broadest meter display range, determine sample suitability. The supplied K=1 probe is rated to 200 mS/cm, but the meter manual recommends K=10 for measurements above 100 mS/cm. Choose the cell and calibration for the method; an optional high-range electrode is not included.

PC800 front panel with pH mode and temperature displayed. Display values are illustrative.
PC800 front panel with pH mode and temperature displayed. Display values are illustrative.
Which 800 or 820 benchtop kit fits my work?Click or tap to compare all six benchtop configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.

Choose the electrode for the sample.

Two probes with different jobs

The non-refillable 201T-F uses a lithium-glass pH membrane, gel KCl reference and integrated temperature sensor. The 2301T-F uses a K=1 platinum-black conductivity cell in a POM body and its own temperature sensor. Both have BNC/RCA connections. Neither is a single pH-plus-conductivity probe; use the correct sensor and temperature connection for the active mode. The supplied K=1 probe is rated to 200 mS/cm, but the meter manual recommends K=10 for measurements above 100 mS/cm. Choose the cell and calibration for the method; an optional high-range electrode is not included.

A display that supports the method

The backlit LCD shows the selected primary measurement and temperature, with stability, calibration and storage indicators. Optional HOLD locks a reading after stabilization; M+ saves it. A slope display between pH calibration points helps identify deterioration. These aids do not replace clean standards, appropriate immersion or an independent check of calibration performance.

Conductivity-derived results with adjustable settings

Conductivity, TDS, salinity and resistivity share the conductivity electrode. TDS is calculated using a selectable factor of 0.40 to 1.00, default 0.71, rather than measured as a separate chemical analysis. Specify the factor and temperature reference in the procedure before comparing results across instruments.

Know what this configuration supplies.

Included item Order contents
PC800 instrument AI523 benchtop combination meter; pH and conductivity measured in separate modes.
201T-F and 2301T-F electrodes One pH/temperature electrode and one conductivity/temperature electrode, each with BNC/RCA connections.
Six calibration bottles pH 4.00, 7.00, 10.01; 84 µS/cm, 1413 µS/cm, 12.88 mS/cm. Manual: 50 mL per bottle.
602 flexible electrode holder Positioning support, not a powered stirring accessory.
Power and USB accessories 9 V adapter and USB cable. Current page lists a PC-Link flash drive; manual calls the software medium a disk.
Documentation User manual and quick guide.
Supplied 2301T-F conductivity/temperature electrode. This is separate from the pH electrode.
Supplied 2301T-F conductivity/temperature electrode. This is separate from the pH electrode.

Match the sample and preparation method.

Routine laboratory water samples

Use for compatible aqueous samples, buffer preparation and repeatable checks where the supplied sensors match the matrix. The 201T-F is not the preferred general answer for ultrapure water, strong solvents or prolonged hot-sample testing.

Teaching and comparative measurements

Separate pH and conductivity modes make the difference between acidity and ionic conduction explicit. Run the two measurements sequentially and link them with a sample identifier; the meter does not generate a simultaneous combined pH/EC sample row.

Process and environmental checks

Suitable workflows include collected water samples and compatible process solutions within probe limits. Establish sampling, rinsing and acceptance criteria. A conductivity-derived TDS result does not identify individual ions or establish drinking-water safety.

201T-F electrode body with the storage bottle removed. Handle the glass sensing end gently.
201T-F electrode body with the storage bottle removed. Handle the glass sensing end gently.

Calibrate each channel.
Connect temperature for the active probe.

Connect the pH electrode to pH/mV and the conductivity electrode to COND. The temperature RCA input is shared, so connect the temperature lead belonging to the probe being used. Place the relevant sensing end and temperature sensor in the same representative sample. The supplied holder positions electrodes; it does not stir or heat the sample.

PC800 supports one to three pH calibration points with USA or NIST recognition, and one to four conductivity points. Recognizing several buffer values does not mean five-point pH calibration. The 201T-F instructions call for three-point calibration with a newly connected probe. Use fresh standards, rinse between solutions and calibrate conductivity from low to high concentration.

pH automatic compensation corrects electrode response to temperature, not the actual temperature dependence of sample chemistry. Conductivity compensation instead refers results to a chosen temperature, adjustable from 15 to 30°C, default 25°C. Its coefficient is adjustable from 0.00 to 9.99%/°C, default 2.00%/°C; zero turns compensation off. Choose a coefficient appropriate to the solution rather than assuming the default is universally correct.

Understand the sensing end and connections.

Supplied 201T-F pH/temperature electrode with BNC and RCA plugs and storage cap.
Supplied 201T-F pH/temperature electrode with BNC and RCA plugs and storage cap.
Close view of the 201T-F glass sensing end and protective shield, not a separate conductivity sensor.
Close view of the 201T-F glass sensing end and protective shield, not a separate conductivity sensor.
Original manufacturer sensing-end illustration for 201T-F, the pH/temperature electrode supplied with PC800.
Original manufacturer sensing-end illustration for 201T-F, the pH/temperature electrode supplied with PC800. “Fast / Accurate / Stable” is the manufacturer’s design wording. Response time, stability and achieved accuracy depend on calibration, sample conditions and probe condition; they have not been independently tested here.
Original manufacturer 2301T conductivity/temperature sensor graphic. The current kit uses the 2301T-F connector variant; its K=1 cell covers up to 200 mS/cm.
Original manufacturer 2301T conductivity/temperature sensor graphic. The current kit uses the 2301T-F connector variant; its K=1 cell covers up to 200 mS/cm. “Fast / Accurate / Stable” is the manufacturer’s design wording. Response time, stability and achieved accuracy depend on calibration, sample conditions and probe condition; they have not been independently tested here. The meter manual recommends K=10 above 100 mS/cm; the supplied K=1 probe’s published rating is not the recommended cell selection for every sample.

KCl for pH storage.
Clean water for the conductivity cap.

Keep the 201T-F sensing tip in clean Apera 3M KCl storage solution, AI1107, when idle. Its gel reference is sealed and is not refilled. Rinse with distilled or deionized water before and after measurement, but never use pure water for long-term pH-electrode storage. Do not rub the glass membrane.

The 2301T-F has a different requirement: its storage cap contains distilled or deionized water. Replace that water if contaminated, rinse the cell between samples and gently release trapped bubbles before reading. Keep both electrical connectors clean and dry. The IP54 meter is splash-resistant, not an immersion instrument.

The 201T-F product page specifies 0 to 13 pH and 0 to 60°C, while its linked manual lists 0 to 14 pH and 0 to 80°C. Use the narrower published limits until the supplied revision is confirmed. Its manual also cautions against prolonged testing above 50°C, frequent extreme-pH exposure and low-ionic-strength water.

PC800 rear connections. pH/mV and COND are separate BNC inputs; temperature uses the shared RCA input.
PC800 rear connections. pH/mV and COND are separate BNC inputs; temperature uses the shared RCA input.
Original manufacturer LCD schematic, not a physical photograph. 1 mode; 2 reading; 3 USB; 4 timed storage; 5 date/time/reminders; 6 date/time labels; 7 measurement units; 8 calibration units; 9 calibration value or memory number; 10 temperature units; 11 M+ save and RM recall; 12 temperature; 13 ATC automatic or MTC manual compensation; 14 completed calibration; 15 HOLD; 16 stable-reading symbol. One primary mode is measured at a time.
Original manufacturer LCD schematic, not a physical photograph. 1 mode; 2 reading; 3 USB; 4 timed storage; 5 date/time/reminders; 6 date/time labels; 7 measurement units; 8 calibration units; 9 calibration value or memory number; 10 temperature units; 11 M+ save and RM recall; 12 temperature; 13 ATC automatic or MTC manual compensation; 14 completed calibration; 15 HOLD; 16 stable-reading symbol. One primary mode is measured at a time.

Read the display. Check the measurement mode.

Use the physical controls for measurement, calibration and the documented record functions. Check units, temperature, calibration indicators and the selected parameter before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Use calibration solutions and settings appropriate to the parameter and fitted electrode. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Save the selected mode.
Keep the sample identity with it.

The model-specific 800-series manual assigns PC800 1000 stored records; its 500-record figure applies to the single-parameter PH800 and EC800. A legacy PC800 gallery graphic still says 500, so the manual is the basis here. Records contain record number, date, time, measurement, unit and temperature. Do not interpret capacity as 1000 simultaneous multi-parameter sample bundles.

Manual M+ storage and automatic interval storage are available. Legacy PC-Link sorts downloaded readings by pH, mV and conductivity. During connected real-time logging, readings go to the computer rather than also being saved in the meter. Export and verify records before clearing memory; retain sample identifiers and calibration checks in your laboratory record.

The legacy manual describes Windows PC-Link, not Mac software. Current kit pages additionally link a newer Web PC-Link service. These are distinct workflows: confirm the meter revision, USB driver and browser support before depending on the newer route. The web application's own compatibility message names Chrome, Edge and Opera, while the kit page also names Firefox. Universal browser or Mac operation is not established here. No software installation or live instrument connection was tested. USB export and timestamped records are useful documentation tools, not a claim of GLP compliance, an audit trail or validated LIMS integration.

Manufacturer example of PC800 USB transfer to legacy desktop PC-Link. Computer is not included. The obsolete 500-set footer is excluded; the model-specific manual specifies 1000 mode-specific records.
Original manufacturer legacy USB-workflow illustration. The software screen is a family example labeled PH800, not a verified session for this delivered meter or a kit-inventory photograph. Use the stated kit list and current software requirements; software and meter-connected export have not been tested here.

Compare a TestBench benchtop alternative.

Alternative format: Apera PC950 Benchtop pH and Conductivity Meter Kit with 606 TestBench. The linked TestBench model has a different bench arrangement, record workflow and kit specification. Compare the exact supplied electrode, accessories and data features rather than assuming similar model names mean identical hardware or software.

PC800 buyer questions

Which electrodes are actually supplied?

The current PC800 AI523 list names 201T-F pH/temperature and 2301T-F conductivity/temperature electrodes. LabSen 211, MP500 and 2401T-F belong to the PC820 configuration, not this standard PC800 kit.

Can it read pH and conductivity at the same time?

No. The exact manual explicitly excludes simultaneous pH and conductivity measurement. The selected primary mode is displayed with temperature; switch modes and temperature leads for the second measurement.

What are the pH and conductivity specifications?

The meter spans -2.00 to 19.99 pH, with 0.01 or 0.1 pH resolution and ±0.01 pH ±1 digit accuracy. Conductivity spans 0 to 200 mS/cm; the manual states ±1.0% full scale ±1 digit, while the page omits the digit term. Probe limits are narrower.

Are all recognized calibration standards included?

No. The six supplied solutions are pH 4.00, 7.00, 10.01 and conductivity 84 µS/cm, 1413 µS/cm, 12.88 mS/cm. The manual specifies 50 mL each. Recognized 111.8 mS/cm is not listed as included.

Is the storage capacity 500 or 1000?

For PC800, the exact manual and current specification say 1000 records. The old 500-set image conflicts. Each record follows the active measurement mode; the meter does not acquire a combined pH/EC row.

Can I use an ORP electrode?

Yes, the ±1999 mV mode supports an appropriate separately purchased ORP electrode. Resolution is 1 mV and meter accuracy is ±0.1% full scale ±1 digit. An ORP electrode is not supplied.

What powers the meter, and is a stirrer included?

The kit includes a 9 V adapter, specified for 120 V AC, 60 Hz input and 9 V DC/300 mA output. The 602 flexible holder is included, but no stirrer, heater or printer is listed.

What is the current US warranty?

The US product page provides a three-year limited instrument warranty and six months for probes from delivery. Coverage addresses qualifying defects, with exclusions for misuse, accidental damage, wear, improper storage and unauthorized work.

Confirm the exact configuration before ordering.

Review PC800 AI523 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / US SKUPC800 / AI523
    Meter pH range-2.00 to 19.99 pH
    pH resolution / accuracy0.1 or 0.01 pH / ±0.01 pH ±1 digit
    Supplied pH electrode201T-F; page: 0 to 13 pH, 0 to 60°C; manual differs
    Conductivity range / accuracy0 to 200 mS/cm / page: ±1.0% full scale; manual adds ±1 digit
    Supplied conductivity electrode2301T-F; K=1; probe page lower limit 0.5 µS/cm The supplied K=1 probe is rated to 200 mS/cm, but the meter manual recommends K=10 for measurements above 100 mS/cm. Choose the cell and calibration for the method; an optional high-range electrode is not included.
    Conductivity resolution0.01/0.1/1 µS/cm; 0.01/0.1 mS/cm
    TDS / salinity / resistivity0 to 100 g/L / 0 to 100 ppt / 0 to 100 MΩ·cm
    Calibration capacitypH 1 to 3 points; conductivity 1 to 4 points
    Temperature / accuracy0 to 100°C / ±0.5°C ±1 digit
    Compensation rangespH 0 to 100°C; conductivity 0 to 50°C; auto or manual
    Memory / output1000 mode-specific records / USB
    ProtectionIP54; keep connectors dry
    Limited warranty3 years instrument; 6 months probes; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI523
    Blue Tiger SKUBTS-AI523
    Order unit1 exact 800 or 820 Series kit
    Order contentsPC800 instrument: AI523 benchtop combination meter; pH and conductivity measured in separate modes.; 201T-F and 2301T-F electrodes: One pH/temperature electrode and one conductivity/temperature electrode, each with BNC/RCA connections.; Six calibration bottles: pH 4.00, 7.00, 10.01; 84 µS/cm, 1413 µS/cm, 12.88 mS/cm. Manual: 50 mL per bottle.; 602 flexible electrode holder: Positioning support, not a powered stirring accessory.; Power and USB accessories: 9 V adapter and USB cable. Current page lists a PC-Link flash drive; manual calls the software medium a disk.; Documentation: User manual and quick guide.

    Apera Manufacturer Limited Warranty

    Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.

    Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.

    PC800 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.

Questions about a product? Ask us here.