Achieve precise water quality analysis with the HI83303 benchtop multiparameter photometer, expertly designed for aquaculture applications. This advanced instrument facilitates the measurement of 12 critical water quality parameters across 20 distinct methods, providing a comprehensive solution for aquatic environments. Its innovative optical system features high-efficiency LEDs, precision narrow band interference filters, a dedicated focusing lens, and dual detectors—a silicon photodetector for accurate absorbance measurements and a reference detector to ensure consistent light source stability. This sophisticated design guarantees highly accurate and repeatable photometric results with every test.
Engineered with the needs of the aquaculture industry in mind, the HI83303 is an indispensable tool for maintaining optimal chemical and environmental conditions, thereby contributing to disease prevention and enhanced production. This versatile photometer enables monitoring of vital parameters such as alkalinity, calcium, nitrite, and phosphate. Alkalinity plays a crucial role in buffering pH fluctuations and storing CO2, essential for photosynthesis and oxygen production in ponds. Maintaining specific calcium levels is fundamental for proper fish growth and skeletal development. Excessive nitrite can be detrimental to fish by interfering with oxygen transport in the bloodstream, while phosphate, though necessary for plant growth, can lead to harmful algal blooms if present in excess, reducing dissolved oxygen critical for a healthy aquatic ecosystem.
Integrated digital pH electrode input expands the meter’s functionality, allowing precise pH measurements using a traditional glass electrode. Intelligent digital pH electrodes feature a built-in microchip that stores all calibration data, enabling "hot-swap" capabilities for seamless electrode changes without the need for recalibration, which significantly streamlines workflow. All pH readings benefit from automatic temperature compensation, provided by a thermistor located within the sensing bulb, ensuring rapid and accurate temperature integration.
The HI83303 also includes an absorbance measurement mode, compatible with Hanna Instruments' CAL Check™ standards for system validation. This mode empowers users to conduct their own concentration versus absorbance studies at five selectable wavelengths (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm). This feature is invaluable for implementing custom chemical methodologies and serves as an excellent educational tool for demonstrating the principles of absorbance and Beer-Lambert Law.
Enhanced connectivity is provided through two USB ports: a host port for easy data transfer to a flash drive, and a micro USB-B port for connection to a computer or as an alternative power source. For ultimate convenience and portability in the field, the meter can also be powered by its internal 3.7 VDC Lithium-polymer rechargeable battery.
Please note: Reagents are not included with this photometer and must be purchased separately.
Key Features:
-
Multi-Parameter Measurement: Accurately measures 12 vital water quality parameters across 20 distinct methods.
-
Advanced Optical System: Features high-efficiency LEDs, narrow band filters, and a reference detector for superior photometric precision.
-
Digital pH Electrode Input: Allows for precise pH and temperature measurements with intelligent, auto-calibrating electrodes.
-
CAL Check™ Functionality: Enables quick and easy validation of the photometric system's performance using Hanna's certified standards.
-
Custom Absorbance Mode: Offers flexibility to create custom concentration versus absorbance curves at selectable wavelengths for unique chemical methods or educational purposes.
-
Comprehensive Data Logging: Stores up to 1000 readings with user and sample identification for thorough record-keeping and traceability.
-
Convenient USB Connectivity: Facilitates effortless data transfer to a PC or flash drive in .CSV format for seamless integration with spreadsheet programs.
-
Battery Status Indicator: Provides clear visibility of remaining battery life, ensuring uninterrupted operation.
-
Helpful Error Messages: Offers on-screen alerts and guidance for troubleshooting photometric and pH-related issues.
-
Backlit LCD Display: Ensures clear viewing in diverse lighting conditions with an intuitive, user-friendly interface.
-
Integrated Reaction Timer: Guarantees consistent and repeatable timing for all photometric measurements, enhancing reliability.
-
Units & Chemical Forms Display: Clearly presents relevant units of measure and chemical forms with each reading for easy interpretation.
-
Effortless Result Conversion: Allows for quick conversion of readings to different chemical forms with a simple touch.
-
Protective Cuvette Shield: Minimizes stray light interference, contributing to higher measurement accuracy.
Key Benefits:
-
Comprehensive Aquaculture Monitoring: One versatile instrument for a wide spectrum of essential water quality parameters in aquatic farming.
-
Enhanced Measurement Reliability: Advanced optical components ensure consistently precise and accurate readings, crucial for critical aquaculture parameters.
-
Streamlined pH Analysis: Digital pH input simplifies testing, offering rapid and accurate pH and temperature results.
-
Assured Performance: CAL Check™ provides confidence in the photometer's operational integrity, verifying system accuracy.
-
Flexible Application: Absorbance mode allows for user-defined methods and is ideal for educational demonstrations of photometric principles.
-
Optimized Data Management: Easy logging and transfer capabilities support efficient record-keeping and detailed analysis.
-
Seamless Data Integration: Exportable .CSV format ensures compatibility with standard spreadsheet software for convenient data handling.
-
Uninterrupted Operation: Clear battery indication prevents unexpected power loss during critical testing.
-
Intuitive Troubleshooting: On-screen error messages guide users, minimizing downtime and maintaining measurement accuracy.
-
User-Friendly Interface: A clear, backlit display and intuitive controls simplify operation for all skill levels.
-
Consistent Results: The built-in reaction timer guarantees repeatable photometric measurements, enhancing data reliability.
-
Clear Data Interpretation: Display of units and chemical forms alongside readings ensures easy understanding of results.
-
Increased Efficiency: Rapid conversion of results to various chemical forms saves time and effort.
-
Improved Accuracy: The cuvette cover effectively minimizes external light interference, ensuring measurement integrity.
-
Space-Saving Design: Combines multiple testing capabilities into a single, compact benchtop unit.
-
Simplified Electrode Handling: Digital pH probes are designed for easy connection and management, enhancing user experience.
-
Precision pH Measurements: Automatic temperature compensation for pH readings guarantees high accuracy.
Key On-Screen Features
Effortless Method Selection
Users can easily select any of the 20 measurement methods via the dedicated METHOD button, simplifying operation.
Advanced Data Logging
Store up to 1000 measurement readings with user and sample IDs for comprehensive data management and future recall.
Professional pH Measurement
Transform the photometer into a professional pH meter with temperature compensation, automatic two-point calibration, and GLP features.
IDEAL APPLICATIONS: Environmental Monitoring, Water and Wastewater Treatment, Industrial Quality Control, Education, Agriculture and Aquaculture, Beverage Analysis.
Advanced Optical System
Innovative Design
The HI83303 features an innovative optical system with a beam splitter for simultaneous absorbance and reference detection. The reference detector actively compensates for light source drift, ensuring unparalleled photometric performance.
High Efficiency LED Light Source
LED light sources offer superior luminous efficiency, providing more light with less power consumption and minimal heat generation, enhancing optical component and electronic stability. LEDs also offer better output in the blue/violet spectrum compared to traditional tungsten lamps.
High-Quality Narrow Band Interference Filters
These filters ensure greater wavelength accuracy (+/- 1 nm) and high efficiency (up to 95% transmission), resulting in a brighter, stronger light source. This leads to enhanced measurement stability and reduced wavelength error compared to less efficient filters.
Reference Detector for a Stable Light Source
The internal reference system, utilizing a beam splitter and reference detector, actively compensates for any light source drift due to power fluctuations or ambient temperature changes, ensuring stable and reliable measurements between blank and sample readings.
Large Cuvette Size
The HI83303 accommodates a 25 mm path length round glass cuvette. This larger size, combined with advanced optics, minimizes rotation errors and the longer path length ensures accurate measurements, even in low absorbance samples.
Focusing Lens for Greater Light Yield
A focusing lens in the optical path ensures that all light exiting the cuvette is collected and precisely focused onto the silicon photodetector, eliminating errors from cuvette imperfections and the need for indexing, leading to more consistent results.