Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments
Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC pH Electrode Apera Instruments

Apera LabSen 851-S Pre-Pressurized pH Electrode for Highly Viscous Samples, BNC

$195.00

    LabSen 851-S is a non-refillable, pre-pressurized glass pH electrode for viscous liquids such as coatings, syrups, resins and glue. Its BNC connection carries pH only; use a separate compatible temperature probe when automatic compensation is required.

    • Current manufacturer PN: AI3163
    • pH range: 0–13 pH
    • Temperature range: 0–100°C / 32–212°F

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / LABSEN 851-S / AI3163

Viscous samples.
A pressurized reference.

LabSen 851-S is a non-refillable, pre-pressurized glass pH electrode for viscous liquids such as coatings, syrups, resins and glue. Its BNC connection carries pH only; use a separate compatible temperature probe when automatic compensation is required.

Manufacturer LabSen 851-S product reference.
Manufacturer LabSen 851-S product reference. Tap or click the image for a larger view.
Choose the right probe and supporting setupClick or tap to compare your optionsCompare below — click or tap here to close
Apera diagram of the LabSen pre-pressurized reference design.
Apera diagram of the LabSen pre-pressurized reference design. Tap or click the image for a larger view.

Pressure helps the junction
keep working.

The pre-pressurized reference design promotes electrolyte flow through the ceramic junction in viscous samples. This is the key distinction when a conventional reference struggles to maintain contact through a thick liquid.

The electrode is non-refillable. Do not try to open it or add refill solution to its internal reference. Storage care remains necessary even though there is no routine refilling.

S glass for
a responsive sensing end.

Apera uses its low-impedance S membrane and a silver-ion-trap reference system in a lead-free glass body. The hemispherical sensing membrane is designed for responsive pH testing within the published operating window.

The glass body and sensing tip still need careful handling. Improved membrane strength is not a license to scrape vessel walls or force the electrode into hard material.

Manufacturer LabSen sensor-technology and application graphic.
Manufacturer LabSen sensor-technology and application graphic. Tap or click the image for a larger view.
Apera silver-ion-trap reference illustration.
Apera silver-ion-trap reference illustration. Tap or click the image for a larger view.

Trap silver ions.
Protect reference stability.

The manufacturer diagram explains the silver-ion-trap reference architecture. Reference construction and junction behavior matter alongside the sensing glass when choosing an electrode for difficult samples.

Calibrate with suitable fresh buffers, rinse between solutions and allow a stable reading. Clean deposits with a method appropriate to the contamination and the electrode instructions.

BNC pH output.
Temperature handled separately.

LabSen 851-S has no built-in temperature sensor. Its BNC connection provides the pH signal; automatic temperature compensation requires a compatible separate temperature probe.

The current manufacturer specification is 0–13 pH and 0–100°C. Confirm these limits against the sample rather than relying on broader values from an older family catalog.

LabSen 851-S — Product dimensions and sensing detail
LabSen 851-S — Product dimensions and sensing detail. Tap or click the image for a larger view.

What this order includes.

Order detail Configuration
Product LabSen 851-S
Manufacturer part number AI3163
Blue Tiger SKU BTS-AI3163
Order contents One LabSen 851-S pH electrode. Meter and separate temperature probe are not included.

Check the fit
before ordering.

Specification Detail
Current manufacturer PN AI3163
pH range 0–13 pH
Temperature range 0–100°C / 32–212°F
Body / dimensions Lead-free glass; Ø12 × 120 mm
Membrane S glass; hemispherical
Reference / junction Silver ion trap / ceramic
Electrolyte Pre-pressurized gel KCl; non-refillable
Temperature sensor None
Connector / cable BNC / 3 ft

Match the stated limits and configuration to your procedure. The Product Specifications tab repeats the order details for quick reference.

Compare related products.

Apera LabSen 851-H / 853-H / 855 Pre-Pressurized pH Electrode for Highly Viscous Samples with High Alkalinity or Salinity

Apera PH850 Portable pH Meter Kit with 201T-F Electrode

Apera MP500 Temperature Probe, RCA Connector, AI1350

LabSen 851-S buyer questions

Which samples is it designed for?

Highly viscous liquids such as coatings, syrups, resins and glue, within the electrode’s chemical and temperature limits.

What does pre-pressurized mean here?

Its reference system is pressurized to promote electrolyte flow through the junction in viscous samples.

Can I refill the electrode?

No. LabSen 851-S is the non-refillable pre-pressurized model. Do not attempt to refill its internal reference.

Does it include temperature measurement?

No. Use a separate compatible temperature probe for ATC or enter temperature manually on the meter.

Which connector does it use?

BNC for pH. The temperature connection, if required, comes from a separate probe.

What are the current operating limits?

The manufacturer currently specifies 0–13 pH and 0–100°C. Use these exact-model limits when selecting it.

What is the current manufacturer part number?

Apera currently identifies LabSen 851-S as AI3163.

Is a meter supplied with it?

No. This listing is for one electrode. Confirm the meter and temperature-probe arrangement before ordering.

Choose the configuration
that fits your work.

Review the order contents and the required host meter and application before ordering. Contact Blue Tiger Scientific if you need help matching the part.

Back to price and ordering ↑

    LabSen 851-S specifications

    SpecificationDetail
    Current manufacturer PNAI3163
    pH range0–13 pH
    Temperature range0–100°C / 32–212°F
    Body / dimensionsLead-free glass; Ø12 × 120 mm
    MembraneS glass; hemispherical
    Reference / junctionSilver ion trap / ceramic
    ElectrolytePre-pressurized gel KCl; non-refillable
    Temperature sensorNone
    Connector / cableBNC / 3 ft

    Ordering information

    SpecificationDetail
    Manufacturer part numberAI3163
    Blue Tiger SKUBTS-AI3163
    Order contentsOne LabSen 851-S pH electrode. Meter and separate temperature probe are not included.

    Apera’s six-month limited electrode warranty covers qualifying defects in materials and workmanship from delivery, subject to its terms and exclusions.

    For setup, compatibility or troubleshooting support, contact Blue Tiger Scientific with the model, order number and a description of the issue.

    Contact Blue Tiger Scientific before returning a product. Return eligibility and instructions depend on the store’s applicable return policy and the condition of the item.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat