Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-320 Lively 3AP Electrophoresis Power Supply Power Supply Major Science
Major Science MP-320 Lively 3AP Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science
Major Science MP-320 Lively 3AP Electrophoresis Power Supply Power Supply Major Science
Major Science MP-320 Lively 3AP Electrophoresis Power Supply Power Supply Major Science
Major Science MP-310 Lively 300V Electrophoresis Power Supply Power Supply Major Science

Major Science MP-310 Lively 300V Electrophoresis Power Supply

$583.00

    Turn repeat gel methods into ready-to-run programs. The Major Science MP-310 brings constant-voltage, constant-current and constant-power control together with stored programs and a clear colour display.

    • 5–300 V in 1 V increments; 1–700 mA in 1 mA increments; 150 W maximum output.
    • Up to six steps per program, storage for 30 program files and pause/resume without resetting the timer.
    • Four pairs of output terminals and a 2.4-inch TFT colour LCD showing running and setting conditions. Supply only; gel apparatus separate.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MAJOR SCIENCE · MP-310

Make repeat runs easier to set up and follow

The MP-310 is a useful step up when your gel bench needs more than a basic two-stage controller. Store recurring methods, program up to six stages and choose constant voltage, current or power to match the protocol. Its 5–300 V, 1–700 mA and 150 W output envelope suits methods that need flexible control without a 500 V supply.

A 2.4-inch TFT colour LCD displays running and setting conditions, keeping the details of the method visible at the bench. Four pairs of output terminals, timed or continuous operation and pause/resume control make this a practical platform for a shared electrophoresis station.

Major Science MP-310 exact-model Lively electrophoresis power supply
Exact MP-310 manufacturer photograph. One standalone power supply; gel apparatus is separate.

5–300 V

Voltage setting range; 1 V increments.

1–700 mA

Current setting range; 1 mA increments.

150 W

Maximum output power; consider voltage and current together.

Why choose MP-310 for this bench?

Keep recurring methods ready

Store up to 30 program files with as many as six steps each. Build a library around the methods your team actually runs, reducing repeated entry of the same sequence of conditions.

Choose the parameter that matters

Constant-voltage, constant-current and constant-power modes let the controller follow the requirement in your protocol. Voltage adjusts in 1 V increments and current in 1 mA increments.

Pause without rebuilding the timer

Pause and resume a run without resetting the timer. The colour display keeps running and setting conditions together, helping you review the setup before starting or continuing the method.

Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family application illustration. The separate gel tank and setup leads are not included with this standalone supply.

From prepared gel to a repeatable run sequence

At a shared gel bench, select the program for the prepared gel and buffer system, then compare its mode, electrical settings and timing with the day's method. Check the gel apparatus and connections before starting, and use the display to review running conditions as the separation proceeds. Stored settings make setup more convenient while leaving the method check in the operator's hands.

For a method that changes conditions between stages, build the sequence into a program rather than re-entering each stage during the run. When using multiple terminal pairs, plan compatible run conditions and check the overall load against the supply ratings. Match the electrical limits of every connected apparatus, not just the power supply.

See the whole setup, then refine the limits

The MP-310's microprocessor controller supports voltage/current automatic crossover and displays all running and setting conditions on its colour screen. When you select a target constant mode, the other two parameters automatically go to their maximum values; you can then adjust them. Review those limits for your apparatus before starting, especially when changing from one control mode to another.

Protective features include no-load and leakage detection, overload detection, over-temperature protection and shrouded plugs and sockets. Sudden-load-change detection is also available with the appropriate enabling setting. These features support a well-managed bench workflow alongside proper lids, dry connections and isolation of the output before reconnecting equipment.

MP-310 display and navigation-button detail crop from the exact manufacturer photograph
Exact MP-310 control detail. Displayed example conditions are not a recommended gel protocol.

Build a method library, not a stack of handwritten settings

Use up to six steps per program to define a sequence of running conditions, and store up to 30 program files for recurring work. Built-in typical running conditions provide a starting point, while manually editable programs let you enter the settings established for your own gel and apparatus.

The timer supports up to 9,999 minutes in constant mode and 999 minutes in program mode, with alarm and continuous-operation options. Pause/resume preserves the timer rather than resetting it. The instrument also provides automatic recovery after a power failure; include that behaviour in your laboratory's interruption procedure when deciding whether a run remains suitable to continue.

Up to 6 steps

Define the sequence of conditions required by your method.

30 program files

Keep recurring methods available at the bench.

Pause and resume

Resume without resetting the run timer.

Match the control mode to the method and the load to 150 W

Use constant voltage for a method defined by voltage, constant current for one defined by current, or constant power when the protocol specifies power control. In every mode, the MP-310 remains limited to 300 V, 700 mA and 150 W output. Its 200 W input specification is a separate mains-side figure, not extra power available to the gel.

Calculate output power as volts multiplied by amperes: 300 V at 500 mA equals 150 W, while 200 V at 700 mA equals 140 W. The combination of 300 V and 700 mA would require 210 W and is outside the operating envelope. Use these relationships to assess capacity, then select the actual settings and limits from your method and apparatus requirements.

MP-310 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol
Source-grounded voltage × current arithmetic, not a run protocol. Ratings apply to the instrument.
MP-310 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Detail crop from the MP-310 manufacturer photograph. Two of the four terminal pairs are shown.

Four terminal pairs, with deliberate connection checks

The MP-310 provides four pairs of output terminals. The right-hand bank shown here contains two of those pairs; the other two are on the opposite side of the front panel. Match every connected apparatus to the run conditions and the instrument limits.

The specified protective functions include no-load and leakage detection, overload detection, over-temperature protection, and shrouded plugs and sockets. Sudden-load-change detection requires the appropriate enabling setting. Stop and isolate the output before changing equipment connections.

Fit a shared electrophoresis station

The Lively case is stackable, and the published instrument dimensions are approximately 215 × 335 × 104 mm. That can help you plan a station around the available bench area while keeping the display and connections accessible.

The photograph shows two separate Lively-family instruments to illustrate the case design. Each MP-310 order is for one power supply. Follow the supplied setup and ventilation instructions for the actual installation.

Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
Manufacturer Lively-family stacking illustration. Two power supplies are shown; this listing supplies one unit.

The stored-program choice for methods up to 300 V

Choose MP-310 when you need constant-power control, a reusable program library or more than two stages within a 300 V method. Compared with MINI-300, it also raises the current ceiling from 400 to 700 mA and the output-power ceiling from 60 to 150 W, while offering four rather than two terminal pairs.

If a simple constant-voltage or constant-current method is the priority, a MINI model may be enough. For higher-demand Lively workflows, MP-320 offers up to 3,000 mA and 300 W at a 300 V ceiling; MP-510 reaches 500 V with 300 W output capacity. Select additional capacity for a defined method need rather than program storage alone, which all three Lively models provide.

Compare the five Major Science options

MINI-300 power supply

MINI-300

10–300 V · 10–400 mA · 60 W

2 pairs · Constant V/I · 2 steps

Compact routine gel work within 300 V and 60 W.

Alternative model: view MINI-300

MINI-500 power supply

MINI-500

10–500 V · 1–400 mA · 120 W

2 pairs · Constant V/I · 2 steps

Higher voltage and a 1 mA current minimum in the compact format.

Alternative model: view MINI-500

MP-310 power supply

MP-310

5–300 V · 1–700 mA · 150 W

4 pairs · Constant V/I/P · 6 steps; 30 files

Stored methods and constant-power control within 300 V and 150 W.

Current model

MP-320 power supply

MP-320

5–300 V · 10–3,000 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

The current-first option, with a 3 A current ceiling.

Alternative model: view MP-320

MP-510 power supply

MP-510

5–500 V · 1–800 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

500 V range with Lively programming and 300 W output.

Alternative model: view MP-510

Choose the voltage, current and power envelope together. Ratings are instrument limits, not separate allowances for every terminal pair.

What does this order cover?

Catalog number MP-310 identifies the standalone Major Science Lively 300V Power Supply. The order is for the power supply rather than a complete electrophoresis system or a set of gel tanks.

Choose the gel apparatus and consumables to match your method. When replacing an existing supply, share the apparatus model, required control mode and expected voltage, current and power demand with Blue Tiger Scientific to help check the selection.

If the order depends on a particular lead, mains plug or carton accessory, ask Blue Tiger Scientific to confirm that requirement before purchase.

Bench tip: After changing the constant-control mode, review the other two electrical limits before starting. MP-310 initially sets those parameters to their maxima, so adjust them to suit the connected apparatus and method.

MP-310 buyer questions

Is MP-310 rated for 150 W or 200 W output?

Maximum output power is 150 W. The 200 W figure is the input specification and should not be used to size the electrophoresis load. Check the method against 300 V, 700 mA and 150 W together.

What voltage and current settings are available?

MP-310 provides 5–300 V in 1 V increments and 1–700 mA in 1 mA increments. Its constant-voltage, constant-current and constant-power modes all operate within the unit's 150 W output ceiling.

How many methods and stages can I program?

The instrument stores up to 30 program files, with up to six steps per program. Programs can be edited manually, and built-in typical running conditions are available as starting points for setup.

What is the maximum timer duration?

The timer reaches 9,999 minutes in constant mode and 999 minutes in program mode. MP-310 also supports continuous operation, an alarm and pause/resume without resetting the timer.

What should I check when selecting a constant mode?

Check the target setting and the other two electrical limits. Selecting a target constant mode automatically sets the other parameters to their maxima, after which you can change them to suit the method and connected apparatus.

Do four terminal pairs provide four times the rated output?

No. MP-310 has four pairs of output terminals, but the instrument ratings remain 300 V, 700 mA and 150 W. Plan the complete connected setup against those ratings and compatible operating conditions.

What bench space and mains supply does MP-310 require?

The instrument measures approximately 215 × 335 × 104 mm (W × L × H), weighs approximately 2.1 kg and has a stackable case. It accepts 100–240 V AC, 47–60 Hz, and is specified for operation at 4–40°C.

Does the MP-310 order include a complete gel system?

No. MP-310 is the standalone Lively 300V power-supply SKU. Gel apparatus and consumables are selected separately to suit the workflow; check the apparatus ratings and connection requirements when planning the installation.

    SpecificationDetail
    BrandMajor Science
    ModelMP-310
    ProductLively 300V electrophoresis power supply
    Output voltage5–300 V; 1 V increments
    Output current1–700 mA; 1 mA increments
    Maximum output power150 W
    Input power, not output200 W
    Output modesConstant voltage, current or power
    ControllerMicroprocessor
    Output-terminal pairs4 pairs
    Display2.4-inch TFT color LCD
    ProgramUp to 6 steps; 30 stored program files
    TimerConstant mode: up to 9,999 minutes; program mode: up to 999 minutes; alarm/continuous operation
    Specified safety featuresNo-load, leakage and overload detection; over-temperature protection; shrouded plugs and sockets; sudden-load-change detection when enabled
    Input mains rating100–240 V AC, 47–60 Hz
    Operating temperature4–40°C
    Unit dimensions, W × L × HApproximately 215 × 335 × 104 mm
    ConstructionPolycarbonate housing with flame-retardant ABS faceplate
    Instrument weight, not shipping weightApproximately 2.1 kg / 4.6 lb
    Pause/resumeWithout resetting the timer
    Automatic recovery after power failureYes
    Case designStackable
    Program editingBuilt-in typical running conditions and manually editable programs
    Mode selection behaviorSelecting a target constant mode initially sets the other two parameters to maximum; the user may then change them

    Ordering Information

    Catalog no.Configuration
    MP-310One standalone power supply. Gel apparatus and workflow consumables are selected separately.

    Ordering, shipping and product support

    Before ordering: Match the voltage, current, output power and control mode required by your method and gel apparatus. MP-310 is a standalone power supply. Contact Blue Tiger Scientific if a particular lead, mains plug or carton accessory is essential to your order.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Availability and dispatch timing depend on the supplier. Shipping estimates are not guaranteed delivery dates; contact us before ordering for a time-critical experiment.

    Non-defective returns: Major Science products are final sale unless return eligibility is confirmed in writing by Blue Tiger Scientific before purchase, based on manufacturer approval. The general 14-day return-request window does not establish return eligibility for these products. Any approved return is subject to the conditions, charges and shipping instructions confirmed in writing. Do not return equipment without an RMA. Orders already accepted remain subject to the terms applicable when the order was placed.

    Defective, damaged or incorrectly supplied items: These follow separate claim procedures. Contact Blue Tiger Scientific promptly and retain the original packaging. Applicable warranty terms and rights required by law remain separate from this non-defective return restriction.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These downloads are a technical catalogue and product brochure, not an operating manual. Follow the instructions supplied with your system.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.