Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Major Science MP-320 Lively 3A power supply with color display and four terminal pairs
Major Science MP-320 exact-model Lively electrophoresis power supply
MP-320 display and navigation-button detail crop from the exact manufacturer photograph
MP-320 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
MP-320 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol
Major Science MP-320 Lively 3A power supply with color display and four terminal pairs
Major Science MP-320 exact-model Lively electrophoresis power supply
MP-320 display and navigation-button detail crop from the exact manufacturer photograph
MP-320 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
MP-320 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol

Major Science MP-320 Lively 3AP Electrophoresis Power Supply

$1,220.00

    Give current-demanding methods room to run. The Major Science MP-320 combines a 3,000 mA current ceiling with 300 W output and stored multistep control for electrophoresis workflows within 300 V.

    • 5–300 V in 1 V increments; 10–3,000 mA in 10 mA increments; 300 W maximum output.
    • Constant voltage, current or power; up to six steps per program and 30 stored program files.
    • Four pairs of output terminals and a 2.4-inch TFT colour display; standalone power-supply SKU.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MAJOR SCIENCE · MP-320

Choose current capacity, not just a bigger voltage number

When your electrophoresis method needs more current rather than a higher voltage ceiling, the MP-320 is the focused choice. Its 10–3,000 mA range brings high-current capability to the Lively platform, alongside 5–300 V adjustment and a 300 W maximum output.

Constant voltage, current and power modes let you follow the parameter your protocol actually specifies. Add four pairs of output terminals, editable programs and a colour display, and you have a practical controller for a bench with established methods to repeat and new conditions to develop.

Major Science MP-320 exact-model Lively electrophoresis power supply
Exact MP-320 manufacturer photograph. One standalone power supply; gel apparatus is separate.

5–300 V

Voltage setting range; 1 V increments.

10–3,000 mA

Current setting range; 10 mA increments.

300 W

Maximum output power; consider voltage and current together.

Why choose MP-320 for this bench?

More current for the method

A 3,000 mA ceiling makes MP-320 the high-current option in this five-model range. It is a meaningful upgrade when current demand, rather than voltage, is the constraint.

Less repeated setup

Store 30 program files with up to six steps each, so recurring methods can start from saved conditions instead of a fresh sequence of entries.

Keep the run in view

The 2.4-inch TFT colour LCD displays running and setting conditions. Pause and resume without resetting the timer when your workflow calls for an interruption.

Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family application illustration. The separate gel tank and setup leads are not included with this standalone supply.

Build the run around the gel and buffer you use

For a horizontal agarose or vertical PAGE workflow, begin with the apparatus rating and your established method. Prepare the gel and buffer, load the samples and secure the apparatus as directed before connecting it with the output off. Choose MP-320 when the required current and power call for its additional capacity, not simply because the tank has a matching connector.

Select the operating mode, enter the method's conditions and review the limits before starting. Watch the displayed values as the run progresses and use your protocol's endpoint criteria. Four terminal pairs provide connection options, while the supply's voltage, current and power ratings remain the limits for the instrument.

Set the target, then check the boundaries

Choose constant voltage for a method defined by voltage, constant current for a method defined by current, or constant power when the protocol specifies power control. Voltage adjusts in 1 V increments and current in 10 mA increments, giving the MP-320 a clear operating range for current-demanding work.

When a constant mode is selected, the other two parameters automatically move to their maximum values and can then be changed. Review them against the apparatus and method before starting. The microprocessor controller provides automatic voltage/current crossover, while the colour screen keeps setting and running conditions visible.

MP-320 display and navigation-button detail crop from the exact manufacturer photograph
Exact MP-320 control detail. Displayed example conditions are not a recommended gel protocol.

Turn a recurring sequence into a saved method

Use up to six programmed steps when your method changes conditions during a run. For example, a validated PAGE procedure may specify an initial stage followed by a different separation stage. MP-320 lets you build the required sequence and keep it among 30 stored program files for the next batch.

Built-in typical running conditions offer starting points, and programs can be edited manually to match your method. Constant-mode timing reaches 9,999 minutes and program-mode timing reaches 999 minutes, with an alarm and continuous operation also available. Pause/resume preserves the timer rather than forcing a restart.

Up to 6 steps

Define the sequence of conditions required by your method.

30 program files

Keep recurring methods available at the bench.

Pause and resume

Resume without resetting the run timer.

Use the 3 A capacity inside the 300 W envelope

Power equals voltage multiplied by current in amperes. At 100 V, a 3,000 mA load represents 300 W; at 300 V, 1,000 mA represents the same 300 W. These arithmetic examples show why the MP-320's highest voltage and highest current are not available together: 300 V at 3,000 mA would require 900 W.

Choose V, I or W control according to the method, then set appropriate limits for the other parameters. In voltage control, current follows the connected load; in current control, voltage responds to it; in power control, voltage and current vary within their limits. Allow for changing load conditions rather than planning every run at the maximum, and always respect the apparatus rating.

MP-320 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol
Source-grounded voltage × current arithmetic, not a run protocol. Ratings apply to the instrument.
MP-320 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Detail crop from the MP-320 manufacturer photograph. Two of the four terminal pairs are shown.

Four terminal pairs, with deliberate connection checks

The MP-320 provides four pairs of output terminals. The right-hand bank shown here contains two of those pairs; the other two are on the opposite side of the front panel. Match every connected apparatus to the run conditions and the instrument limits.

The specified protective functions include no-load and leakage detection, overload detection, over-temperature protection, and shrouded plugs and sockets. Sudden-load-change detection requires the appropriate enabling setting. Stop and isolate the output before changing equipment connections.

Fit a shared electrophoresis station

The Lively case is stackable, and the published instrument dimensions are approximately 215 × 335 × 104 mm. That can help you plan a station around the available bench area while keeping the display and connections accessible.

The photograph shows two separate Lively-family instruments to illustrate the case design. Each MP-320 order is for one power supply. Follow the supplied setup and ventilation instructions for the actual installation.

Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
Manufacturer Lively-family stacking illustration. Two power supplies are shown; this listing supplies one unit.

MP-320 is the current-first Lively choice

Choose MP-320 when you need more than MP-310's 700 mA current ceiling or 150 W maximum output while staying at or below 300 V. Both offer Lively programming, so the reason to choose MP-320 is its electrical capacity rather than additional program steps.

If the method instead needs voltage above 300 V, compare MP-510: it reaches 500 V with an 800 mA ceiling and the same 300 W maximum output. For lighter-duty methods that need only constant voltage/current and two-step control, a MINI model may be sufficient. Match the actual method before choosing the larger supply.

Compare the five Major Science options

MINI-300 power supply

MINI-300

10–300 V · 10–400 mA · 60 W

2 pairs · Constant V/I · 2 steps

Compact routine gel work within 300 V and 60 W.

Alternative model: view MINI-300

MINI-500 power supply

MINI-500

10–500 V · 1–400 mA · 120 W

2 pairs · Constant V/I · 2 steps

Higher voltage and a 1 mA current minimum in the compact format.

Alternative model: view MINI-500

MP-310 power supply

MP-310

5–300 V · 1–700 mA · 150 W

4 pairs · Constant V/I/P · 6 steps; 30 files

Stored methods and constant-power control within 300 V and 150 W.

Alternative model: view MP-310

MP-320 power supply

MP-320

5–300 V · 10–3,000 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

The current-first option, with a 3 A current ceiling.

Current model

MP-510 power supply

MP-510

5–500 V · 1–800 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

500 V range with Lively programming and 300 W output.

Alternative model: view MP-510

Choose the voltage, current and power envelope together. Ratings are instrument limits, not separate allowances for every terminal pair.

What does this order cover?

Catalog number MP-320 identifies the standalone Major Science Lively 3AP electrophoresis power supply. This listing is for the power supply, not a complete gel-system package.

Choose the gel apparatus and consumables separately to suit your method. For a replacement installation, check the apparatus ratings and connection requirements against the MP-320 before ordering.

If the order depends on a particular lead, mains plug or carton accessory, ask Blue Tiger Scientific to confirm that requirement before purchase.

Bench tip: Record the voltage and current observed during a representative run, not just the chosen setpoint. Those values help you judge whether a replacement supply needs more current capacity, more voltage range or more output power.

MP-320 buyer questions

What are the MP-320 output ranges?

MP-320 offers 5–300 V in 1 V increments and 10–3,000 mA in 10 mA increments, with 300 W maximum output power. Check all three limits together when matching a method.

Can MP-320 supply 3 A at 300 V?

No. That combination would require 900 W. The maximum output is 300 W, so the available operating point must satisfy the voltage, current and power limits together.

How many output-terminal pairs does it have?

There are four pairs of shrouded output terminals. The 3,000 mA and 300 W ratings apply to the instrument, not four separate allocations of those ratings.

How long can I run a method?

The timer reaches 9,999 minutes in constant mode and 999 minutes in program mode. Timed operation with an alarm and continuous operation are available, and pause/resume does not reset the timer.

What happens after a power failure?

MP-320 includes automatic recovery after power failure. Incorporate that restart behaviour into your laboratory procedure and assess any interrupted experiment according to your method.

Which protective functions are provided?

MP-320 includes no-load, leakage and overload detection, over-temperature protection and shrouded plugs and sockets. Sudden-load-change detection is also available when the appropriate setting is enabled. Follow the apparatus safety procedure for every run.

What bench space and mains supply does MP-320 need?

The instrument measures approximately 215 × 335 × 104 mm (W × L × H), weighs approximately 2.1 kg and has a stackable case. Mains input is 100–240 V AC, 47–60 Hz; the specified operating-temperature range is 4–40°C.

Should I choose MP-320 or MP-510?

Choose MP-320 for current requirements up to 3,000 mA within a 300 V ceiling. Choose MP-510 for methods needing up to 500 V within its 800 mA ceiling. Both provide 300 W maximum output, constant V/I/P modes, six-step programming and 30 stored files.

    SpecificationDetail
    BrandMajor Science
    ModelMP-320
    ProductLively 3AP electrophoresis power supply
    Output voltage5–300 V; 1 V increments
    Output current10–3,000 mA; 10 mA increments
    Maximum output power300 W
    Output modesConstant voltage, current or power
    ControllerMicroprocessor
    Output-terminal pairs4 pairs
    Display2.4-inch TFT color LCD
    ProgramUp to 6 steps; 30 stored program files
    TimerConstant mode: up to 9,999 minutes; program mode: up to 999 minutes; alarm/continuous operation
    Specified safety featuresNo-load, leakage and overload detection; over-temperature protection; shrouded plugs and sockets; sudden-load-change detection when enabled
    Input mains rating100–240 V AC, 47–60 Hz
    Operating temperature4–40°C
    Unit dimensions, W × L × HApproximately 215 × 335 × 104 mm
    ConstructionPolycarbonate housing with flame-retardant ABS faceplate
    Instrument weight, not shipping weightApproximately 2.1 kg / 4.6 lb
    Pause/resumeWithout resetting the timer
    Automatic recovery after power failureYes
    Case designStackable
    Program editingBuilt-in typical running conditions and manually editable programs
    Mode selection behaviorSelecting a target constant mode initially sets the other two parameters to maximum; the user may then change them

    Ordering Information

    Catalog no.Configuration
    MP-320One standalone power supply. Gel apparatus and workflow consumables are selected separately.

    Ordering, shipping and product support

    Before ordering: Match the voltage, current, output power and control mode required by your method and gel apparatus. MP-320 is a standalone power supply. Contact Blue Tiger Scientific if a particular lead, mains plug or carton accessory is essential to your order.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Availability and dispatch timing depend on the supplier. Shipping estimates are not guaranteed delivery dates; contact us before ordering for a time-critical experiment.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These downloads are a technical catalogue and product brochure, not an operating manual. Follow the instructions supplied with your system.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat