Major Science MINI-300 electrophoresis power supply with front display and two terminal pairs
Exact Major Science MINI-300 power supply with front controls and two output-terminal pairs
MINI-300 in a manufacturer electrophoresis application photograph; tank and cables shown as workflow context, not included items
Detail crop of the exact MINI-300 Mode, Step 1, Step 2 and Start/Stop controls
Detail crop showing the two red-black shrouded output-terminal pairs on MINI-300
MINI-300 output-limit examples: 300 V at 200 mA equals 60 W; 150 V at 400 mA equals 60 W; 100 V at 400 mA equals 40 W; arithmetic examples, not a run protocol
MINI-300 two-step program guide with voltage or current and time settings for Step 1 and Step 2; time zero means continuous operation
Major Science MINI-300 electrophoresis power supply with front display and two terminal pairs
Exact Major Science MINI-300 power supply with front controls and two output-terminal pairs
MINI-300 in a manufacturer electrophoresis application photograph; tank and cables shown as workflow context, not included items
Detail crop of the exact MINI-300 Mode, Step 1, Step 2 and Start/Stop controls
Detail crop showing the two red-black shrouded output-terminal pairs on MINI-300
MINI-300 output-limit examples: 300 V at 200 mA equals 60 W; 150 V at 400 mA equals 60 W; 100 V at 400 mA equals 40 W; arithmetic examples, not a run protocol
MINI-300 two-step program guide with voltage or current and time settings for Step 1 and Step 2; time zero means continuous operation

Major Science MINI-300 Mini Pro 300V Electrophoresis Power Supply

$429.00

    Precise mini-gel control without a large bench footprint. The Major Science MINI-300 supports horizontal agarose and vertical PAGE workflows with constant-voltage or constant-current operation.

    • 10–300 V and 10–400 mA adjustment ranges; 60 W maximum output.
    • Two output-terminal pairs, a two-step program and timed or continuous operation.
    • Standalone power supply; gel tanks and workflow consumables sold separately.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MAJOR SCIENCE · MINI-300

Power routine agarose and PAGE runs without crowding the bench

The MINI-300 brings constant-voltage or constant-current control, two pairs of output terminals and a two-step program to a compact 140 × 191 mm footprint. Use it for horizontal agarose or vertical polyacrylamide gel electrophoresis when your method fits its 10–300 V, 10–400 mA and 60 W operating limits.

Set voltage in 1 V increments or current in 1 mA increments, choose a timed run with an alarm, or select continuous operation. It is a focused power supply for mini-gel work, not an oversized controller packed with features your bench may not need.

Exact Major Science MINI-300 power supply with front controls and two output-terminal pairs
Exact MINI-300 manufacturer photograph. This listing is for the standalone power supply; gel equipment is separate.

10–300 V

Voltage setting range, in 1 V increments.

10–400 mA

Current setting range, in 1 mA increments.

60 W

Maximum output power; consider voltage and current together.

Choose the control mode that fits the method

Constant voltage

Use when your protocol calls for a defined voltage. Current depends on the connected gel setup and its resistance, within the supply limits.

Constant current

Use when your protocol specifies current control. Voltage responds to the connected load, within the supply limits.

Two-step programming

Set sequential operating conditions for a method that changes between two stages. MINI-300 offers constant V or I, not constant-power operation.

MINI-300 in a manufacturer electrophoresis application photograph; tank and cables shown as workflow context, not included items
Manufacturer application photograph showing the exact MINI-300. Tank, leads and other demonstration equipment are not offered as an included bundle.

A real lab workflow, not just a list of ratings

Major Science positions MINI-300 for both horizontal agarose and vertical polyacrylamide electrophoresis. That makes it a practical option for benches moving between nucleic-acid gels and protein gel workflows, provided each method and apparatus fits the supply specifications.

The two terminal pairs allow two gel setups to be connected for suitable simultaneous work. Plan the combined electrical demand within the unit ratings. Do not interpret two socket pairs as a specification for independently programmable channels.

Before you connect: Match the apparatus ratings, lead connectors and protocol requirements. The equipment shown in this application photograph illustrates a workflow, not the contents of this order.

See the settings before you start

The front panel separates Mode, Step 1, Step 2 and Start/Stop controls. Indicator labels identify voltage, current and time beside the display, so the physical controls support the same three decisions you make while setting up a run.

For timed work, the specified timer reaches 999 minutes and includes an alarm. A time value of 0 selects continuous operation until stopped manually. Select the mode and duration for your validated method rather than treating the factory preset as a universal gel recipe.

Detail crop of the exact MINI-300 Mode, Step 1, Step 2 and Start/Stop controls
Detail crop from the exact MINI-300 manufacturer photograph, not a substituted MINI-500 panel.
MINI-300 two-step program guide with voltage or current and time settings for Step 1 and Step 2; time zero means continuous operation
Source-grounded setup guide. Step values must come from your method; this is not a prescribed electrophoresis protocol.

Two steps when your method needs a second stage

MINI-300 supports a two-step program with voltage or current and time settings. This lets a suitable electrophoresis method move through two defined stages without buying a larger multi-step controller.

If voltage or current is set to 0 in Step 2, the system will not proceed to that second step. If a method needs up to six stages and stored program files, compare the MP-310, MP-320 and MP-510 below rather than assuming MINI-300 includes those Lively-series features.

Understand the 60 W limit before choosing a supply

Voltage, current and power are related. MINI-300 is rated to 300 V, 400 mA and 60 W, but 300 V × 400 mA would be 120 W. Those two maxima therefore are not a simultaneous 120 W operating point.

For comparison, 300 V × 200 mA equals 60 W, while 150 V × 400 mA also equals 60 W. These are arithmetic illustrations of the published limits, not settings recommended for a particular gel. Select a supply with enough headroom for the actual connected load and method.

Need more headroom? MINI-500 raises the ceiling to 500 V and 120 W. MP-310 provides up to 150 W, while MP-320 and MP-510 provide up to 300 W.

MINI-300 output-limit examples: 300 V at 200 mA equals 60 W; 150 V at 400 mA equals 60 W; 100 V at 400 mA equals 40 W; arithmetic examples, not a run protocol
Illustrative output-limit arithmetic. Power ratings apply to the unit, not separately to each terminal pair.
Detail crop showing the two red-black shrouded output-terminal pairs on MINI-300
Exact MINI-300 terminal detail. The two output pairs are not described as independently programmed channels.

Connections and protection, stated accurately

MINI-300 has two red/black pairs of shrouded output terminals. Major Science specifies no-load detection and shrouded plugs and sockets for this model. These are useful protective features, not a reason to bypass normal electrophoresis safety procedures.

Use the apparatus safety lid as directed, keep connections dry, and stop and isolate the electrical output before changing connections. Never interpret the power supply rating as permission to exceed the gel tank or cell rating.

The input rating is 100–240 V AC, 50–60 Hz, 2 A. That is the mains specification, not a 2 A electrophoresis output. The specified current output remains 10–400 mA.

Which Major Science power supply do I need?

Start with the output range and control mode your method requires, then consider the number of connections and program complexity. Choose the smaller supply when it meets the method; move up for a specific electrical or programming need, not simply a larger model number.

All figures are model limits, not simultaneous maximum-voltage/maximum-current guarantees. Terminal-pair counts are not a claim of independently programmed channels.

Pair the power supply with the gel format you actually use

What does this order cover?

Catalog number MINI-300: One standalone Mini Pro 300V electrophoresis power supply. This is not an MJ-105A, MT-108 or vertical-cell bundle.

Select the gel apparatus, compatible leads and consumables for your existing workflow separately. If your purchase depends on a particular mains plug or an accessory being in the carton, ask Blue Tiger Scientific to confirm that exact requirement before ordering.

Bench tip: Check all three output limits when replacing another supply. Matching only the voltage printed on the old unit can miss a current, wattage or programming requirement.

MINI-300 buyer questions

What are the MINI-300 voltage, current and power limits?

MINI-300 provides 10–300 V in 1 V increments and 10–400 mA in 1 mA increments, with 60 W maximum output power. These are separate limits; the maximum voltage and maximum current cannot be assumed to be available together.

Can MINI-300 run two gels at the same time?

Major Science specifies two pairs of output terminals and describes simultaneous two-gel use. The connected setups must suit the operating conditions and stay within the unit ratings. Do not multiply the current or power specification by the two terminal pairs.

Does MINI-300 have independent channels or constant-power mode?

MINI-300 is specified with two output-terminal pairs, constant voltage or constant current, and a two-step program. The manufacturer does not describe independently programmable channels or constant-power operation for this model. The Lively MP-310, MP-320 and MP-510 add constant-power mode and more programming features.

Does MINI-300 work with MT-108 and MJ-105A gel systems?

Major Science lists the MJA-Mini300 package with MJ-105A and the MJAT-Mini300 package with MJ-105A, MT-108 and MINI-300. These establish the documented system pairings. This standalone MINI-300 listing does not include either tank, and run settings must suit the tank and protocol.

What is the difference between MINI-300 and MINI-500?

MINI-300 is rated to 300 V, 400 mA and 60 W, with a 10 mA minimum current. MINI-500 is rated to 500 V, 400 mA and 120 W, with a 1 mA minimum current. Both offer two terminal pairs, constant V/I and a two-step program; neither should be assumed to have the Lively constant-power feature.

Can I program a second step or run continuously?

Yes. MINI-300 supports a two-step program and a timer up to 999 minutes with an alarm. A time setting of 0 means continuous operation until manually stopped. Setting voltage or current to 0 in Step 2 prevents the system from proceeding to Step 2.

Does the MINI-300 order include a gel tank or a complete electrophoresis kit?

No gel tank or complete gel-workflow bundle is offered under this standalone MINI-300 listing. Order the needed gel apparatus and consumables separately. Contact Blue Tiger Scientific if you need confirmation of a particular lead, mains plug or carton accessory.

What mains power and bench space does MINI-300 require?

The input rating is 100–240 V AC, 50–60 Hz, 2 A. The unit measures approximately 140 × 191 × 84 mm (W × L × H) and weighs approximately 1 kg. These are instrument figures, not packed shipping dimensions or shipping weight. The operating-temperature range is 4–40°C.

    SpecificationDetail
    BrandMajor Science
    ModelMINI-300
    ProductMini Pro 300V electrophoresis power supply
    Output voltage, Steps 1 and 210–300 V; 1 V increments
    Output current, Steps 1 and 210–400 mA; 1 mA increments
    Maximum output power60 W
    Output modesConstant voltage or constant current
    ControllerMicroprocessor
    Output-terminal pairs2 pairs
    DisplayLED
    Program2-step program
    TimerUp to 999 minutes with alarm; continuous when time is set to 0
    Specified safety featuresNo-load detection; shrouded plugs and sockets
    Input mains rating100–240 V AC, 50–60 Hz, 2 A
    Operating temperature4–40°C
    Unit dimensions, W × L × HApproximately 140 × 191 × 84 mm
    ConstructionPolycarbonate housing and aluminum base plates
    Instrument weight, not shipping weightApproximately 1 kg / 2.2 lb

    Ordering Information

    Catalog no.Configuration
    MINI-300One standalone Mini Pro 300V electrophoresis power supply. Gel tanks/cells and consumables are separate purchases.

    Manufacturer Preset Values

    Factory presets are listed for reference, not as a validated protocol for your gel.

    StepPreset
    Step 1300 V; 16 mA; 15 minutes
    Step 2300 V; 24 mA; 120 minutes
    Time set to 0Continuous operation until manually stopped
    Step 2 voltage or current set to 0The system does not proceed to Step 2

    Ordering, shipping and product support

    Before ordering: Match your method and gel apparatus to the required voltage, current and output-power ranges. MINI-300 is a standalone power supply. Contact Blue Tiger Scientific if you need confirmation of a specific lead connector, mains plug or carton accessory before ordering.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Availability and dispatch timing depend on the supplier. Shipping estimates are not guaranteed delivery dates; contact us before ordering for a time-critical experiment.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These downloads are a technical catalogue and product brochure, not an operating manual. Follow the instructions supplied with your system.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat