Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Default Title Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Default Title Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments
Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317) Pocket pH and ORP Tester Apera Instruments

Apera PR60F Dual-Channel Flat pH/ORP Tester Kit (AI317)

$230.00

    Two channels. One clear view.

    • See pH, ORP and temperature together without switching between measurement screens.
    • Use StableRead to hold stabilized pH and ORP values instead of judging every changing digit.
    • Move between water samples and moistened flat surfaces with the same flat sensor assembly.
    • Start with supplied pH buffers, an ORP standard, storage solution and calibration vials in a carrying case.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA / PR60F / AI317

Read pH and ORP together. Know when each result is ready.

Check water quality and suitable flat surfaces with one pocket-sized tester. The PR60F brings simultaneous pH and ORP measurements, temperature readings and a replaceable flat-surface probe into a portable calibration kit.

Apera PR60F pocket tester with pH, ORP and temperature on its display.
One screen for pH, ORP and temperature.

Two channels

pH and ORP shown together, with temperature.

Flat sensors

Glass pH and platinum ORP sensing surfaces.

Replaceable probe

Renew the sensing assembly with PR60F-DE.

Which pocket tester fits the job? Compare three options
PR60F: pH + ORP together

PR60F: pH + ORP together

Current kit. Simultaneous dual-channel readings and a combined flat sensing assembly.

PH60F: flat-surface pH

PH60F: flat-surface pH

Alternative format: PH60F flat-surface pH tester for a pH-focused workflow.

ORP60: redox checks

ORP60: redox checks

Alternative format: ORP60 pocket ORP tester when ORP is the measurement you need.

Why choose the PR60F?

Calibrate for the range you actually test

Choose one to three automatic pH calibration points using USA or NIST buffers. The kit supplies pH 4.00, 7.00 and 10.01 buffers, plus a 222 mV ORP standard for the separate one-point ORP calibration.

Two water-quality readings, one view

The dual-channel system measures pH and ORP at the same time, with temperature alongside them on the LCD. In GeneralRead mode, you can watch both live values and use the stability indicators to judge when to record a result.

Apera display diagram showing ORP, pH, temperature, stability indicators and calibration symbols.
Read pH and ORP together, with temperature alongside.
Apera StableRead diagram showing waiting dashes followed by stabilized pH and ORP values.
StableRead holds each result when it is ready.

Let StableRead flag a settled result

StableRead shows dashes while each measurement settles, then holds its stabilized value. The pH and ORP results can appear at different times. A short press restarts the check when you want to confirm a result.

Reach beyond a beaker of water

Flat glass pH and platinum ORP sensors support general water samples and suitable surface checks. For dry paper, fabric and similar surfaces, add a few drops of distilled or deionized water before bringing the probe into contact.

Close-up of the PR60F flat platinum ORP sensor and glass pH sensor, labelled by Apera.
Flat pH and ORP sensors support water samples and suitable surfaces.
Apera PR60F-DE replacement pH/ORP probe on a white background.
PR60F-DE replacement probe, AI317-E; sold separately.

Keep a useful tester in service

A double-junction reference system helps resist sample contamination. When the sensing assembly eventually wears out, the PR60F-DE replacement probe lets you renew the probe rather than replace the entire tester. Recalibrate after fitting a new probe.

Carry the setup from bench to site

The carrying case keeps the tester, calibration solutions and vials together. The IP67-rated body, low-battery warning and two-color backlight make routine checks practical, while correct cap and seal closure help maintain water protection.

Open PR60F carrying case with tester, calibration solutions, vials, storage solution, lanyard and printed guide.
The supplied calibration and storage essentials travel in one case.

Calibration essentials, together in one case

The supplied standards and vials cover pH and ORP setup, with 3M KCl solution for probe storage between uses.

Included item Details
PR60F tester with flat-surface pH/ORP probe Dual-channel tester with temperature measurement and protective probe cap. Quantity: 1.
pH calibration buffers pH 4.00, 7.00 and 10.01 solutions for setting up the range you need.
222 mV ORP standard Reference solution for checking and calibrating the ORP channel; use the temperature-adjusted target value.
pH calibration vials Separate reusable vials for the three supplied pH buffers. Quantity: 3.
ORP calibration vial Dedicated container for the ORP standard. Quantity: 1.
3M KCl storage solution Helps keep the probe hydrated between measurements.
Lanyard A carrying strap for on-site work. Quantity: 1.
Printed instructions Setup and care guidance supplied with the kit; the full user manual is also available below.
Carrying case Organizes the tester, solutions and calibration accessories for transport. Quantity: 1.

From routine water checks to surface measurements

  • Pools and spas
  • Water treatment and environmental monitoring
  • Hydroponics and aquaculture
  • Moistened paper, fabric and suitable flat surfaces

Prepare the sample and probe as directed in the manual. This is not a promise of suitability for every chemical, surface or temperature.

Protect the probe between checks

Rinse with distilled or deionized water before and after testing, then store the probe with 3M KCl solution in the securely closed cap. Pure water is for rinsing; not long-term storage. Calibrate close to your sample temperature, and avoid sample solutions below 5°C or above 45°C where practical to reduce error and probe wear.

Related workflow: Apera 3M KCl electrode storage solution for replenishing the specified storage chemistry. Related workflow: Apera 222 mV ORP calibration standard for the separately calibrated ORP channel. Check the temperature-specific reference value on the standard label.

Questions before you order

Can I see pH and ORP at the same time?

Yes. The PR60F measures pH and ORP simultaneously and shows both values with temperature on the same display. GeneralRead gives you live readings; StableRead holds each result once it has settled. The two stabilized results may appear at different times.

What does StableRead do for me?

It removes the need to choose a result from constantly changing digits. The display waits with dashes, then presents a stabilized pH or ORP value. The manual gives a typical wait of 20 to 60 seconds, depending on the sample and temperature change; not a guaranteed test time. If stabilization takes longer than three minutes, the tester returns to GeneralRead.

Can it test surfaces as well as liquids?

Yes. The flat glass pH and platinum ORP sensors support water samples and suitable flat surfaces. For dry paper or fabric, moisten the test area with a few drops of distilled or deionized water as directed in the manual. Follow the stated preparation method; this does not establish suitability for every surface or chemical.

How should I calibrate pH before the first test?

The manual recommends at least two pH calibration points before use. With the supplied USA buffers, start at pH 7.00, then use pH 4.00 and, when needed, pH 10.01. Complete the sequence without switching the tester off. The instrument supports one to three automatic points and can also use the NIST series through its settings.

Is the ORP calibration target always 222 mV?

No. The included standard is 222 mV at 25°C, but its reference value changes with temperature; for example, it is 227 mV at 20°C. Use the table on the solution label or in the manual when adjusting the one-point ORP calibration.

What temperatures can I measure?

The specified sample-temperature and pH compensation range is 0 to 50°C (32 to 122°F). For better measurement conditions and probe life, the manual advises avoiding sample solutions below 5°C or above 45°C. Calibrate close to the sample temperature, with a difference of less than 10°C. These are sample-related figures, not a separately specified ambient operating range.

How do I care for the probe, and can it be replaced?

Rinse the probe with distilled or deionized water before and after use, and keep it hydrated with 3M KCl solution in the closed cap. Do not store it in pure water. When sensitivity declines beyond recovery, fit a PR60F-DE replacement probe (AI317-E), restore factory settings and recalibrate as the manual directs. Replacement probes are sold separately.

What is included, and what warranty applies?

The kit includes the PR60F tester and probe, pH 4.00/7.00/10.01 buffers, a 222 mV ORP standard, pH and ORP calibration vials, 3M KCl storage solution, a lanyard, printed instructions and a carrying case. Apera’s limited warranty runs for two years on the instrument and six months on the probe from delivery, subject to its stated exclusions.

    SpecificationPR60F
    Measurement parameterspH, ORP (mV) and temperature
    pH range−2.00 to 16.00 pH
    pH resolutionSelectable 0.01 or 0.1 pH
    pH accuracy±0.01 pH ±1 digit
    pH calibration1–3 automatic points; selectable USA or NIST buffer series
    ORP range−1000 to +1000 mV
    ORP resolution / accuracy1 mV / ±2 mV
    ORP calibration1 point; supplied 222 mV standard uses a temperature-dependent reference value
    Sample temperature range0 to 50°C (32 to 122°F)
    Temperature resolution / accuracy0.1°C or °F / ±0.5°C
    pH automatic temperature compensation0 to 50°C (32 to 122°F)
    Measurement modesGeneralRead live readings; StableRead stabilized-value hold
    DisplayTwo-color backlit LCD: white for measurement, green for calibration
    Protection ratingIP67; secure the battery cap and seals correctly
    Power4 × AAA alkaline batteries
    Battery lifeUp to 1,000 hours
    Low-battery indicationYes
    Automatic power-offSelectable 8, 15, 30, 60, 90 or 120 minutes, or off
    Tester dimensions / weight40 × 40 × 178 mm / 133 g
    Kit dimensions / weight255 × 210 × 50 mm / 700 g; not a packed shipping specification
    Replacement probePR60F-DE, SKU AI317-E; sold separately
    Manufacturer limited warranty2 years instrument; 6 months probe; from delivery

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI317
    Store SKUBTS-AI317
    Order unitOne PR60F dual-channel tester kit
    Supplied configurationTester with probe, pH buffers, ORP standard, calibration vials, 3M KCl, lanyard, instructions and case

    Manufacturer limited warranty

    Apera covers the instrument for two years and the probe for six months from delivery against qualifying defects in materials and workmanship. Accidental damage, misuse, normal wear, transport or storage damage, unauthorized repair or modification and other exclusions are not covered. See the manual for the complete terms.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat