Apera Instruments WS200 Fluoride/pH/Conductivity 7-in-1 Portable Meter Kit

$799.00

    Fluoride, pH and conductivity in one IP57 handheld kit, with every standard in the case.

    • F501-S 3-in-1 fluoride probe: 0.02–1900 ppm, 2-point calibration
    • 201T-S pH/ATC: −2.00 to 19.99 pH, 1–3 point calibration
    • 2301T-S cell: conductivity to 199.9 mS/cm, plus TDS, salinity and resistivity
    • Two AA batteries; 800-reading memory

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / WS200 / AI4721

Fluoride, pH and conductivity.
One meter, three probes.

The WS200 measures fluoride with Apera’s F501-S 3-in-1 electrode, pH with the 201T-S, and conductivity with the 2301T-S cell, and converts conductivity to TDS, salinity and resistivity, with temperature from the probes. Apera calls it a 7-in-1 meter: fluoride from 0.02 to 1900 ppm, pH from −2.00 to 19.99, and conductivity across five auto-ranging spans up to 199.9 mS/cm.

The kit arrives in a carrying case with all three electrodes and every standard needed to calibrate them: two fluoride, three pH and a 1413 µS/cm conductivity standard. The handheld is IP57 rated and runs on two AA batteries, for drinking water, surface water and treatment work in the field or the lab.

Apera WS200 portable fluoride meter
WS200 meter. The displayed reading is illustrative, not a sample result.
Choose your water ion meterClick or tap to compare 3 meter kitsChoose an item below - click or tap here to close

Know what arrives
in the carrying case.

Included item Order contents
WS200 meter Handheld IP57 meter in a silicone protective sleeve, two AA batteries.
F501-S fluoride electrode 3-in-1: fluoride ion-selective, reference and temperature elements in one body.
201T-S pH electrode Combination pH electrode with ATC, in a storage bottle.
2301T-S conductivity electrode K = 1 cm⁻¹ cell with ATC, platinum-black plated.
Fluoride calibration solutions 0.19 mg/L and 19.00 mg/L, 50 mL each.
pH buffer solutions pH 4.00, 7.00 and 10.01, 50 mL each.
Conductivity standard 1413 µS/cm, 50 mL.
Spare AA batteries Three.
Screwdriver For the battery cover.
Carrying case Apera lists the kit case at 360 × 270 × 76 mm and 1.5 kg.
Instruction manual WS200 operation, calibration and maintenance.

Kit list follows Apera’s WS200 instruction manual and Apera’s US product page.

Apera WS200 kit in its carrying case with meter, electrodes and calibration solutions
WS200 kit as shipped: meter, electrodes, standards and accessories in the foam-lined case.
WS200 manual fluoride preparation and electrode activation steps
WS200 instruction manual, section 4.1: connect the F501-S, choose the unit and activate the electrode.

Activate the fluoride probe.
Then calibrate at two points.

Connect the F501-S and the meter switches to fluoride mode on its own. A new electrode, or one being used for the first time, soaks in the 19.00 mg/L standard for one hour; in regular use, 10 to 20 minutes is enough. Wait until the reading settles and the smiley-face stability icon stays on before you calibrate. Readings during activation are random.

Press CAL and the meter asks for 0.19 mg/L first, then 19.00 mg/L. Rinse the probe in distilled or deionized water, shake off the excess, dip it, stir gently and let it stand; press CAL again when the stability icon stays on. The L and H icons confirm a two-point calibration. Apera states no stirring or added reagents are needed in the sample.

Protect the fluoride result.

Match the prompt

The meter does not recognize which fluoride standard is in the cup. Use the solution the display asks for, 0.19 mg/L or 19.00 mg/L; the wrong one produces a wrong calibration.

Keep the low standard clean

The 0.19 mg/L standard contaminates easily, and a small amount of carryover causes a large error. Apera recommends replacing the fluoride standards after four to five uses.

Low to high, same temperature

Measure from low to high concentration where you can; going from high to low, rinse first. Keep samples within ±15°C of the standards, and at the same temperature for the best accuracy. Apera lists a sample pH requirement of 5.0–6.0 for fluoride.

Calibrate pH at one, two or three points.

Connect the 201T-S pH/ATC electrode, unscrew its storage bottle and the meter opens in pH mode. Calibration starts at pH 7.00 (C1), then pH 4.00 (C2) and pH 10.01 (C3); press the enter key after any point to stop there. One point at pH 7.00 suits work to ±0.1 pH; use 4.00/7.00 for acidic samples, 7.00/10.01 for alkaline samples, and all three for a wide range or a new electrode.

The meter recognizes buffers from three series: USA (1.68, 4.00, 7.00, 10.01, 12.45), NIST (1.68, 4.01, 6.86, 9.18, 12.45) and CH. Err1 flags an electrode zero point outside ±60 mV and Err2 a slope outside 85–105%. Store the electrode in its bottle of 3M KCl (Apera AI1107); Apera puts its service life at about one to two years.

Purified water compensation

Two optional settings apply pH temperature compensation for purified water and for purified water with ammonia added. Both are off by default.

ORP with an optional probe

Short-press the mode key for mV. With Apera’s 301Pt-S ORP electrode, sold separately, the meter reads −1999 to 1999 mV at 1 mV resolution, ±0.1% FS.

WS200 manual conductivity standard series and calibration range chart
WS200 instruction manual, section 7.4: standard series and calibration range by cell constant.

Conductivity is factory calibrated.
Check it monthly.

Connect the 2301T-S and press CAL in COND mode, then dip the cell in the 1413 µS/cm standard and press CAL when the reading is stable. Apera ships the conductivity function calibrated and recommends recalibrating about once a month, and whenever the cell is new or has been idle. TDS, salinity and resistivity are calculated from conductivity, so they need no separate calibration; press the enter key to step through them.

With the supplied K = 1 cell calibrated at 1413 µS/cm, Apera gives a range up to 100 mS/cm. The meter also accepts 0.1 and 10 cm⁻¹ cells, reference temperatures of 25, 20 or 18°C, and a temperature coefficient from 0.00 to 9.99%/°C, 2.00%/°C by default. Do not brush the platinum-black plates; rinse them with purified water.

WS200 manual LCD display diagram with numbered indicators
WS200 instruction manual, section 3.1: display layout and indicators.

Read the display at a glance.

The backlit LCD shows the parameter, the reading, the unit and the sample temperature together, with a smiley-face icon once the reading is stable and L, M and H icons for the calibration points in use. A battery icon warns when the two AA cells are low.

Five keys run the meter: power, CAL, MODE, enter/backlight and M+/RM. Press M+ when the reading is stable to store it with its number, unit and temperature; hold it to recall stored readings. The backlight times out after 0, 1, 3 or 6 minutes and the meter switches itself off after 0, 10 or 20 minutes, both set in the parameter menu.

Check the specifications.

Fluoride accuracy is ±0.02 ppm or ±5% of reading, whichever is greater, with automatic temperature compensation from 0 to 80°C. pH accuracy is ±0.01 pH ±1 digit, with compensation from 0 to 100°C. Conductivity accuracy is ±1.0% FS, with compensation from 0 to 50°C; TDS reads to 100 g/L, salinity to 100 ppt and resistivity to 100 MΩ·cm.

The meter stores 800 readings with their number, unit and temperature. It measures 65 × 120 × 31 mm and weighs 180 g, runs on two AA batteries and is IP57 rated against dust and water.

WS200 manual technical parameters table
WS200 instruction manual, section 2: technical parameters.

Compare the other water ion kits.

The Apera WS100 (AI4725) is the same fluoride and pH kit without the conductivity cell. For calcium and magnesium hardness, the YD300 (AI4731) uses the same handheld format with Apera’s 601-S hardness electrode.

WS200 buyer questions

What does the F501-S fluoride probe include?

It is a 3-in-1 combination electrode: fluoride ion-selective, reference and temperature elements in one body. Apera states that no stirring or added reagents are needed.

How long does activation take?

One hour in the 19.00 mg/L standard for a new electrode or first use; 10 to 20 minutes in regular use. Start calibrating once the reading is stable.

Which fluoride units can it display?

mg/L, ppm and pF. The meter also shows the electrode mV.

How often should I calibrate fluoride?

Apera recommends calibrating before each use when accuracy matters. If accuracy needs are low, check the probe in a standard first; if the error is small, recalibration is not necessary.

Can it measure ORP?

Yes, in mV mode with Apera’s 301Pt-S ORP electrode, which is sold separately: −1999 to 1999 mV at 1 mV resolution.

Do TDS, salinity and resistivity need their own calibration?

No. They are calculated from conductivity, so calibrating conductivity at 1413 µS/cm covers them. Conductivity is calibrated before the meter leaves the factory.

How should I store the electrodes?

Rinse the fluoride probe, shake off the water and store it dry with its cap on. Keep the pH electrode in its storage bottle of 3M KCl. The conductivity cell can be kept in purified water before use to protect the platinum black.

What does it run on?

Two AA batteries, with three spares in the kit. The meter is IP57 rated and turns itself off after 10 minutes by default.

What warranty applies?

Apera’s limited warranty covers the meter for two years and the probes for six months from delivery, excluding misuse, accidental damage, improper maintenance, unauthorized repair and the other causes in Apera’s terms. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific.

Confirm the exact configuration before ordering.

Review WS200 AI4721 against the parameters you need to report, your sample pH and range, and the standards you will keep on hand. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / manufacturer catalogWS200 / AI4721
    ParametersFluoride, pH, conductivity, TDS, salinity, resistivity, temperature; mV/ORP with optional probe
    Fluoride range / units0.02–1900 ppm / mg/L, ppm, pF
    Fluoride accuracy±0.02 ppm or ±5% of reading, whichever is greater
    Fluoride calibration2-point automatic: 0.19 and 19.00 mg/L
    Fluoride temperature compensation0–80°C, automatic
    Fluoride sample pH5.0–6.0
    pH range / resolution−2.00 to 19.99 pH / 0.1 or 0.01 pH
    pH accuracy±0.01 pH ±1 digit
    pH calibration1–3 points; USA, NIST and CH buffer series
    pH temperature compensation0–100°C, automatic
    mV range / resolution / accuracy−1999 to 1999 mV / 1 mV / ±0.1% FS
    Conductivity range0.00–19.99 µS/cm, 20.0–199.9 µS/cm, 200–1999 µS/cm, 2.00–19.99 mS/cm, 20.0–199.9 mS/cm
    Conductivity resolution / accuracy0.01 / 0.1 / 1 µS/cm and 0.01 / 0.1 mS/cm / ±1.0% FS
    TDS / salinity / resistivity0–100 g/L / 0–100 ppt / 0–100 MΩ·cm
    Conductivity calibration1-point, 1413 µS/cm (factory calibrated)
    Cell constant / reference temperature0.1, 1 or 10 cm⁻¹ / 25, 20 or 18°C
    Conductivity temperature compensation0–50°C, automatic; coefficient 0.00–9.99%/°C
    Data storage800 readings with number, unit and temperature
    Power2 × AA (1.5 V); auto-off 0, 10 or 20 min
    Protection / certificatesIP57 / ISO 9001:2015, CE, RoHS
    Meter dimensions / weight65 × 120 × 31 mm / 180 g
    Kit case dimensions / weight360 × 270 × 76 mm / 1.5 kg
    Manufacturer limited warrantyTwo years for the meter, six months for probes, from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI4721
    Blue Tiger SKUBTS-AI4721
    Order unit1 WS200 meter kit
    Order contentsWS200 meter; F501-S fluoride electrode; 201T-S pH/ATC electrode; 2301T-S conductivity electrode; fluoride standards 0.19 and 19.00 mg/L (50 mL each); pH buffers 4.00, 7.00 and 10.01 (50 mL each); 1413 µS/cm standard (50 mL); three spare AA batteries; screwdriver; carrying case; instruction manual
    Replacement electrodes and solutionsF501-S fluoride electrode (AI4729); 201T-S pH electrode (AI1312); 2301T-S conductivity electrode (AI1313); 301Pt-S ORP electrode, optional (AI1315); 3M KCl soaking solution (AI1107)

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument (SIX MONTHS for the probes) from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    WS200 official documents

    Manufacturer documentation for the WS200. The instruction manual covers setup, calibration, measurement and electrode care. The card opens a PDF in a new tab.