Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH60Z-MS smart pH tester with LabSen electrode
Apera PH60Z-MS complete test kit
Apera PH60Z-MS LabSen pH electrode
Apera PH60Z-MS semi micro
Apera PH60Z-MS long life reference
Apera PH60Z-MS calibration in the CalPod organizer
Apera PH60Z-MS electrode dimension drawing
Apera PH60Z-MS smart pH tester with LabSen electrode
Apera PH60Z-MS complete test kit
Apera PH60Z-MS LabSen pH electrode
Apera PH60Z-MS semi micro
Apera PH60Z-MS long life reference
Apera PH60Z-MS calibration in the CalPod organizer
Apera PH60Z-MS electrode dimension drawing

Apera Instruments PH60Z-MS Smart pH Tester Kit for Small Volumes with LabSen 246-5 Electrode

$299.00

    Small volumes and test tubes: the PH60Z smart tester with the LabSen 246-5 electrode.

    • LabSen 246-5: Ø6 mm semi-micro tip
    • −2.00 to 16.00 pH, ±0.01 pH; ATC 0–100°C
    • Bluetooth ZenTest app: guided calibration, unlimited logging
    • pH 4.00, 7.00 and 10.01 buffers, KCl and CalPod in the case

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH60Z-MS / AI3741

Smart pH for small volumes.
A Ø6 mm tip for test tubes.

The PH60Z-MS pairs Apera’s PH60Z smart tester with the LabSen 246-5 semi-micro pH/temperature electrode. Its Ø6 mm, 100 mm sensing tip fits test tubes and small vessels, and the kit includes a semi-micro container; Apera’s manual puts the minimum sample at more than 60 µL.

The tester works on its own from the keypad, or pairs over Bluetooth with Apera’s free ZenTest app for guided calibration, calibration reminders and unlimited data logging. It reads −2.00 to 16.00 pH at ±0.01 pH, is IP67 rated and runs on four AAA batteries. The kit includes pH 4.00, 7.00 and 10.01 buffers, 3M KCl soaking solution and the CalPod solution organizer in a carrying case.

Apera PH60Z-MS smart pH tester with LabSen 246-5 electrode and ZenTest app on a phone
PH60Z-MS: PH60Z smart tester with the LabSen 246-5 electrode. Phone not included; screen values are illustrative.
Choose your PH60Z LabSen kitClick or tap to compare 8 sample-specific kitsChoose an item below - click or tap here to close

Know what arrives
in the carrying case.

Included item Order contents
PH60Z smart tester Meter body with Bluetooth, IP67, four AAA batteries.
LabSen 246-5 electrode pH/temperature electrode with 8-pin connector, in its storage vial.
pH buffer solutions pH 4.00, 7.00 and 10.01.
3M KCl soaking solution For storing the electrode.
CalPod solution organizer Holds the calibration buffers.
Semi-micro container For small-volume samples.
Protective cap Covers the meter connector.
Carrying case Apera lists it at 255 × 210 × 50 mm and 700 g.
User manual PH60Z-MS setup, calibration and care.

Kit list follows Apera’s PH60Z-MS kit contents.

Apera PH60Z-MS complete test kit contents
PH60Z-MS complete test kit, as shown by Apera.
Apera LabSen 246-5 pH electrode
LabSen 246-5 pH/temperature electrode with 8-pin connector.

Meet the LabSen 246-5.

The LabSen 246-5 has a Ø6 mm, 100 mm long semi-micro tip, so it reaches into test tubes and narrow vessels. Fill the sample above the junction, the white spot on the shaft, so the reading is complete.

It reads pH 0–14 from 0 to 100°C with a ceramic junction and long-life 3 M KCl reference. Use the semi-micro container from the kit for the smallest samples.

Ø6 × 100 mm tip and the semi-micro container
Ø6 × 100 mm tip and the semi-micro container.
Long-life reference system for stability and service life
Long-life reference system for stability and service life.

Calibrate from pH 7.00.
Then add the points you need.

Pour the buffers into the CalPod. Always start at pH 7.00: dip, stir briefly, long-press CAL (the screen turns green), and short-press CAL when the stability icon stays on. Continue straight to pH 4.00 and pH 10.01 without switching the meter off. Powering off between points forces you to start again at pH 7.00.

The meter recognizes USA buffers (1.68, 4.00, 7.00, 10.01, 12.45) or NIST buffers (1.68, 4.01, 6.86, 9.18, 12.45) and confirms each point with an icon. Apera suggests reusing poured buffers up to 10 times, but pH 10.01 only up to 5, and calibrating at the sample’s temperature for the best accuracy. In the ZenTest app, calibration is guided on screen and reminders can be scheduled.

PH60Z manual calibration options table for USA and NIST buffer series
PH60Z user manual, section 4.2: one-, two- and three-point calibration options.
Calibrating the PH60Z-MS in the CalPod solution organizer
Calibrating in the CalPod solution organizer.

Measure, hold, log.

Rinse the electrode, immerse it at least 1 inch, stir briefly to clear bubbles, and take the reading when the stability icon stays on. With Auto-Hold on, the tester locks a reading that has been stable for 10 seconds; short-press CAL to release it.

The PH60Z also reads mV, sets high and low alarm limits that turn the screen red, and switches between °C and °F. In the ZenTest app, every logged reading can carry date, time, location, a photo, the asset, the operator and notes, and you can export by email, AirDrop or messaging apps.

PH60Z manual electrode cleaning table by contamination type
PH60Z user manual, section 6: cleaning agents and soaking times.

Clean it, then store it wet.

Rinse the electrode with distilled or deionized water before and after every measurement, and blot it with a lint-free wipe; never rub the glass. For oils, proteins, scale or unknown deposits, Apera’s table gives the cleaning agent and soak time, followed by 12–24 hours in 3M KCl and a fresh calibration.

Store the electrode in its vial with 3M KCl soaking solution and replace the solution about monthly. Never store it in tap, RO, distilled or deionized water. White crystals around the vial are dried KCl and harmless. Apera expects a pH electrode to last one to two years; replacement LabSen electrodes connect to the same tester.

Check the specifications.

The PH60Z tester reads −2.00 to 16.00 pH at 0.01 resolution, ±0.01 pH ±1 digit, with automatic or manual temperature compensation from 0 to 100°C. It also reads −1000 to 1000 mV (±0.2% F.S) and temperature from 0 to 100°C (±0.5°C ±1 digit), and has a three-color backlight, auto-hold, reading alarms and self-diagnosis.

The LabSen 246-5 reads 0 to 14 pH from 0 to 100°C. The tester runs on four AAA batteries, is IP67 rated, and measures 40 × 40 × 178 mm at 133 g.

LabSen 246-5 electrode dimension drawing
Electrode dimension drawing from Apera’s product page.

Compare the other options.

Apera also sells this electrode in the non-Bluetooth PH60-MS kit (AI3725), with the PH60 tester and no ZenTest app. For general aqueous samples with the standard probe, see the PH60-Z ZenTest tester (AI3711). The model guide above links all eight PH60Z LabSen kits.

PH60Z-MS buyer questions

What is the PH60Z-MS made for?

It pairs the PH60Z smart tester with the LabSen 246-5 semi-micro pH/temperature electrode.

Do I need a phone?

No. Calibration, measurement, Auto-Hold and settings all work from the keypad. The free ZenTest app adds guided calibration, calibration reminders, data logging and export over Bluetooth.

Which buffers come in the kit?

pH 4.00, 7.00 and 10.01, plus 3M KCl soaking solution and the CalPod organizer.

Why must I start calibration at pH 7.00?

The PH60Z sets its zero point at pH 7.00 (or 6.86 NIST) first. If you switch off between points, the next point returns an Er1 error and you start again at pH 7.00.

How should I store the electrode?

In its vial with 3M KCl soaking solution, replaced about monthly. Never in pure, RO, distilled or tap water.

Can I use other electrodes with this tester?

Yes. Apera lists the LabSen 335, 246-5, 845, 835, 865, 855 and 765 electrodes, and the PH60S-E, GS2-E and PH60F-E probes, as compatible with the PH60Z.

What warranty applies?

Apera’s limited warranty covers the tester for two years and the electrode for six months from delivery, excluding accidental damage, improper use, normal wear and the other causes in Apera’s terms. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific.

Confirm the exact configuration before ordering.

Review PH60Z-MS AI3741 against your sample type, pH range and temperature, and whether you want app logging. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / manufacturer catalogPH60Z-MS / AI3741
    Meter pH range / resolution / accuracy−2.00 to 16.00 pH / 0.01 pH / ±0.01 pH ±1 digit
    Temperature compensation0–100°C, automatic or manual
    mV range / resolution / accuracy−1000 to 1000 mV / 1 mV / ±0.2% F.S
    Temperature range / resolution / accuracy0–100°C (32–212°F) / 0.1°C / ±0.5°C ±1 digit
    Calibration1–3 points, automatic; USA (1.68, 4.00, 7.00, 10.01, 12.45) or NIST (1.68, 4.01, 6.86, 9.18, 12.45)
    Display / functions3-color backlight; reading alarm, auto-hold, °C/°F, self-diagnosis
    ConnectivityBluetooth to ZenTest app (iOS, iPadOS, macOS, Android), range up to 10 m; unlimited data logging
    Power / protection4 × AAA batteries / IP67
    Tester dimensions / weight40 × 40 × 178 mm / 133 g
    Case dimensions / weight255 × 210 × 50 mm / 700 g
    LabSen 246-5 Membrane typeS
    LabSen 246-5 HousingLead-free glass
    LabSen 246-5 pH range0–14
    LabSen 246-5 Temperature range0–100°C
    LabSen 246-5 JunctionCeramic
    LabSen 246-5 ReferenceLong-life
    LabSen 246-5 Electrolyte3 M KCl
    LabSen 246-5 Sensing tipØ6 × 100 mm
    LabSen 246-5 temperature sensor / connector30 kΩ NTC / 8-pin
    Manufacturer limited warrantyTwo years for the tester, six months for the electrode, from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI3741
    Blue Tiger SKUBTS-AI3741
    Order unit1 PH60Z-MS smart pH tester kit
    Order contentsPH60Z smart tester; LabSen 246-5 pH/temperature electrode; pH 4.00, 7.00 and 10.01 buffer solutions; 3M KCl soaking solution; CalPod solution organizer; semi-micro container; protective cap; carrying case; user manual
    Related itemsNon-Bluetooth version: PH60-MS (AI3725); 3M KCl soaking solution (AI1107); electrode cleaning solution (AI1166)

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument (SIX MONTHS for the probes) from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PH60Z-MS official documents

    Manufacturer documentation for the PH60Z-MS. The user manual covers setup, keypad operation, calibration, cleaning, storage and troubleshooting. The card opens a PDF in a new tab.