Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera AI7112 8-Pin Connection Adapter for 60 and 60-Z Pocket Testers Default Title Meter Connection Adapter Apera Instruments
Apera AI7112 8-Pin Connection Adapter for 60 and 60-Z Pocket Testers Default Title Meter Connection Adapter Apera Instruments

Apera AI7112 8-Pin Connection Adapter for 60 and 60-Z Pocket Testers

$15.00

    Use a supported 8-pin electrode with your Apera pocket tester.

    • For supported 60-series and 60-Z pocket tester setups
    • Provides the external 8-pin electrode connection
    • Confirm the exact host and electrode pairing
    • AI7112 adapter only; tester and electrode separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / CONNECTION ADAPTER / AI7112

Connect a supported 8-pin electrode to your pocket tester.

AI7112 provides the external 8-pin electrode connection for supported Apera 60-series and 60-Z pocket tester setups. Match the tester and electrode before ordering: connector shape alone does not establish every measurement function or temperature pairing.

Adapter only. The tester and electrode are separate items.

Apera AI7112 8-pin connection adapter, original manufacturer product photograph
Manufacturer-supplied AI7112 product photograph.

The connection you need, without buying another tester.

60 / 60-Z pocket families

Designed for the connection role Apera identifies for these pocket tester families. Verify the complete tester model and electrode, rather than assuming all heads are interchangeable.

External 8-pin electrode connection

Use the adapter where the chosen electrode calls for an installed 8-pin socket on a supported pocket tester.

One adapter, not a sensing probe

AI7112 is the connection accessory. It does not supply the pH glass, reference junction, meter body or calibration solutions.

Which tester and electrode am I connecting?

CURRENT ITEM: AI7112 CONNECTION ADAPTER

Selected connection examples and related tester bodies are shown below. Only the adapter is supplied by this listing. The two electrode links select their specific 8-pin variants.

AI7112 or AI7103: choose the correct connection role.

Accessory Purpose
AI7112 - this item Connection adapter for supported 60-series / 60-Z pocket testers using external 8-pin electrodes.
AI7103 - a different item Converter for supported 8-pin meters, such as the Apera 400/400S series, to use BNC/RCA pH electrodes. It is not this pocket-tester adapter.

Do not choose between these accessories by the words “8-pin” alone. Start with the meter body, then its supported electrode and connection requirements.

Prepare the complete measurement setup.

Identify the exact tester and electrode first. LabSen 805 and LabSen 246-5 are examples whose manufacturer pages explicitly describe PH60 / PH60-Z use with an installed 8-pin socket.

Follow the applicable host and electrode instructions for assembly, alignment, conditioning and calibration. Do not force an unmatched connector. For pH use, calibrate the complete meter/electrode pairing as directed before relying on measurements.

An adapter does not increase the operating limits of the tester or electrode. Use the limits supported by the complete pairing; an electrode’s wider rating does not authorize a wider meter or ATC range.

What this order supplies

Included item Scope
AI7112 connection adapter Adapter accessory only. Tester, electrode and calibration solutions are not supplied by this listing.

Connection tip: Keep the mating contacts clean and dry and follow the exact setup instructions. No adapter-specific waterproof rating, dimensions or construction material are claimed here.

AI7112 buyer questions

What does Apera AI7112 connect?

It provides the 8-pin electrode connection for supported Apera 60-series and 60-Z pocket tester setups. A compatible tester and external 8-pin electrode are required.

Can I use AI7112 with PH60 or PH60-Z?

Apera’s LabSen 805 and LabSen 246-5 pages explicitly describe PH60 and PH60-Z use with an installed 8-pin socket. Verify the exact electrode and tester pairing; the adapter is not a claim that every probe or measurement mode is supported.

Will every 8-pin electrode work through this adapter?

Do not assume so. Matching connector shape is only one requirement. The host must support the electrode’s sensing role, temperature input and operating conditions.

How is AI7112 different from AI7103?

AI7112 is the pocket-tester connection adapter for supported external 8-pin electrodes. AI7103 serves a different purpose: supported 8-pin meters using BNC/RCA pH electrodes. They are not interchangeable accessories.

Does this listing include a meter or electrode?

No. It is the AI7112 connection adapter only. The linked meters and electrodes are separate products.

Does the adapter expand the tester’s measurement range?

No wider measurement or temperature range is promised. Follow the applicable limits of the tester, electrode and complete documented setup. Do not transfer an electrode-only rating to the whole system.

Does AI7112 make the connected setup waterproof?

No adapter-specific IP rating is claimed here. Follow the instructions and rating for the complete documented assembly rather than transferring a meter-body rating to any unverified combination.

Do I need to prepare and calibrate after changing the setup?

Yes. Follow the exact host and electrode instructions for installation, conditioning and calibration. For pH pairings, calibrate with the correct buffers as directed. AI7112 does not include calibration solutions or replace the meter’s calibration procedure.

    SpecificationDetail
    ManufacturerApera Instruments
    Catalog numberAI7112
    Product typePocket-tester connection adapter
    Tester familiesSupported Apera 60-series and 60-Z pocket tester setups
    Electrode connection roleExternal 8-pin electrode connection, subject to exact host/electrode compatibility
    Meter or sensing electrodeNot supplied; adapter accessory only
    Range and ATC limitsDefined by the confirmed host/electrode pairing, not expanded by this adapter

    Ordering Information

    Order detailConfiguration
    Manufacturer catalogAI7112
    Blue Tiger SKUBTS-AI7112
    Order unitOne connection adapter
    Selection noteFor supported 60/60-Z pocket-tester connections; not the AI7103 8-pin to BNC/RCA pH converter

    Product Support

    Before ordering, confirm the complete tester model and external electrode. AI7112 is a connection accessory; the meter and electrode must support the intended measurement and operating conditions.

    Keep the electrical contacts clean and dry. Follow the applicable tester and electrode instructions for assembly, preparation, calibration and care.

    For warranty information or return authorization for this accessory, contact Blue Tiger Scientific before sending any item. A meter-body or electrode warranty should not be assumed to apply to a separate connection adapter.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat