Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

MTC Bio R0215 Reversible Magnetic Bead Separation Rack Default Title Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Default Title Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio
MTC Bio R0215 Reversible Magnetic Bead Separation Rack Reversible Magnetic Bead Separation Rack MTC Bio

MTC Bio R0215 Reversible Magnetic Bead Separation Rack

$216.48

    Keep small-batch bead workflows organized through separation and resuspension. R0215 adapts to microtube or PCR-tube methods in one compact reversible rack.

    • 8 × 1.5/2.0 mL microtubes or 16 × 0.1/0.2 mL PCR tubes
    • Removable magnet sleeve for resuspension without transferring tubes
    • Microtube height rings included; tubes, beads and reagents not included

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MTC BIO · R0215 · MICROTUBE / PCR-TUBE MAGNETIC SEPARATION

Switch small-batch tube formats without changing racks.

Bring manual bead-based purification and cleanup to a compact, reversible bench rack. MTC Bio R0215 supports 8 × 1.5/2.0 mL microtubes or 16 × 0.1/0.2 mL PCR tubes, with a removable magnet sleeve for resuspension and rings to adjust microtube height.

Choose the orientation for your vessel before loading samples. The two formats are alternatives, not simultaneous capacities. One rack is supplied; tubes, beads and reagents are selected separately.

MTC Bio R0215 shown in microtube and PCR-tube orientations; one rack supplied, tubes and liquid not included
Manufacturer views of one R0215 in its two configurations. Tubes and colored liquid are not included.

Built around the steps of a small-batch bead method

Choose the tube format

Eight microtube positions on one side or sixteen PCR-tube positions on the other, including PCR-strip workflows.

Remove the magnetic field

Withdraw the magnet sleeve for resuspension while keeping tubes organized in the rack.

Set microtube height

Included rings adjust the height of the tube exposed to the magnetic field for your setup.

MTC Bio R0215 flip-over format diagram for microtubes or PCR tubes; tubes and liquid not included
Manufacturer flip-over illustration. One rack supplied; tubes and liquid are not included.

Microtubes or PCR tubes: set the orientation first

The microtube side accepts 1.5 mL and 2.0 mL tubes. The reverse side accepts 0.1 mL and 0.2 mL PCR tubes and strips, for up to sixteen tube positions. This makes R0215 useful when small-batch preparation and PCR cleanup use different vessels.

Switch only with the rack unloaded. Identify the format, orient the rack on a stable surface, and check that the exact tubes seat correctly before adding samples. Do not invert a rack containing samples.

Height rings put microtube placement under your control

The microtube wells include height-adjustment rings, and the wells have a manufacturer-specified 10° pitch for tube contact with the magnets. Adjust tube placement to suit the tube geometry and the liquid region used in your method.

A nominal 1.5 mL or 2.0 mL label does not establish the ideal setting. Check seating and collection with the actual tube and working volume before standardizing the procedure.

MTC Bio R0215 microtube side with height-adjustment rings and removable magnet sleeve shown separately
Microtube-side view with height rings and magnet sleeve shown separately. These rack components are included.
MTC Bio R0215 PCR-tube side with magnet sleeve removed from the rack
PCR-tube-side view with the magnet sleeve removed. The image shows included rack components, not a second rack.

Withdraw the sleeve when the method calls for resuspension

The magnets sit in a removable casing. Withdrawing this sleeve lets you resuspend beads without moving the tubes into another rack. Return the sleeve when the protocol requires the next magnetic collection step.

Keep the rack stable as you remove or replace the sleeve, and mix only as your bead-kit protocol directs. The rack does not provide automatic mixing, timed separation or liquid handling.

What bead collection looks like

The manufacturer’s before-and-after photographs illustrate dispersed particles collecting into a localized deposit. Use that visual distinction to check collection before aspirating, while keeping your pipette tip away from the beads.

Manufacturer before-separation example with R0215 and dispersed particles in microtubes; tubes and liquid not included
Before: manufacturer example with dispersed particles. Tubes, beads and liquid are not included.
Manufacturer after-separation example with R0215 and collected particles in microtubes; tubes and liquid not included
After: manufacturer example with particles collected toward the magnet. Tubes, beads and liquid are not included.

Illustrative result, not a timed performance claim. The photographs do not establish a separation time, purity or recovery guarantee. Your bead chemistry, sample, tube and working volume determine the appropriate procedure.

A compact setup with a clear operating sequence

1 · Configure

Choose the microtube or PCR side before loading. Check seating and adjust microtube height as appropriate.

2 · Separate

Use the magnet sleeve for bead collection. Aspirate clear liquid without disturbing the deposit, then follow the wash method.

3 · Resuspend

Withdraw the magnet sleeve when instructed, resuspend according to the method, then replace it for later collection steps.

The rack measures 3.75 × 1.75 × 1.5 in. Allow extra clearance for tube caps, pipetting and sleeve removal. The manufacturer’s magnet ratings are 5000 g pull strength and field strength greater than 5000 gauss; they are not working-volume limits or guarantees of extraction performance.

When a different separation format makes more sense

R0215 · This small-tube rack

Eight 1.5/2.0 mL microtubes or sixteen 0.1/0.2 mL PCR tubes. Choose for low-throughput tube-based methods.

Alternative format: R0250 · Conical tubes

A separate model with three 15 mL positions and three 50 mL positions on opposite faces of the central support. Both sets can remain upright.

R0096 · 96-well plates

Alternative format: R0096 plate separator. For plate-based PCR, assay, deep-well and elution workflows; verify the exact plate geometry.

Choose tubes around your chemistry and workflow

Related workflow: MTC Bio SureSeal S microcentrifuge tubes offer microtube choices for preparation and cleanup. Select 1.5 mL or 2.0 mL formats and verify seating and ring position.

Related workflow: MTC Bio PureAmp PCR tubes and 8-strips provide 0.2 mL options for PCR-tube workflows.

Related workflow: MTC Bio PureAmp qPCR tubes and strips include 0.1 mL and 0.2 mL formats. Confirm the exact tube or strip geometry and cap clearance; these links do not establish compatibility for every variant.

Frequently asked questions

Is MTC Bio R0215 an alternative to the Invitrogen DynaMag-2 magnet?

R0215 is a small-batch format option to evaluate, not a verified drop-in replacement. Thermo Fisher specifies Invitrogen DynaMag-2 for up to sixteen standard 1.5–2 mL microcentrifuge tubes. R0215 holds eight 1.5/2.0 mL microtubes or, in its other orientation, sixteen 0.1/0.2 mL PCR tubes. Its removable magnet sleeve and microtube height rings offer a different setup. Verify tube fit, bead chemistry and protocol performance before changing separators. Invitrogen and DynaMag are trademarks of their respective owners. Blue Tiger Scientific is not affiliated with or endorsed by those brands.

How many microtubes or PCR tubes can R0215 hold?

Use eight 1.5/2.0 mL microtubes in one orientation, or sixteen 0.1/0.2 mL PCR tubes in the other. These are alternative operating configurations, not simultaneous capacities. The PCR side also accommodates PCR strips within its sixteen tube positions. Select the orientation before loading samples.

What is included with R0215?

One reversible magnetic bead separation rack is supplied with a removable magnet sleeve and microtube height-adjustment rings. Microtubes, PCR tubes or strips, magnetic beads, reagents and samples are not included. Photos showing both orientations illustrate one model, not a two-rack package.

What does the removable magnet sleeve do?

It lets you remove the magnetic field from the tube positions for bead resuspension without first transferring the tubes to another rack. Remove the sleeve when your protocol calls for resuspension, mix as directed, and return the sleeve for the next magnetic separation step.

Why are there height-adjustment rings and angled wells?

The microtube rings control the height of the tube exposed to the magnetic field. The manufacturer specifies wells on a 10° pitch for tube contact with the magnets. Check the position using your actual tube and sample volume; there is no universal ring setting for every bead method.

How much bench space does R0215 need?

The manufacturer lists dimensions of 3.75 × 1.75 × 1.5 in. Leave additional working space for opening tube caps, pipetting and withdrawing the magnet sleeve. The rack dimensions are not the shipping-package dimensions.

How strong are the magnets, and how fast will separation be?

MTC Bio’s R0215 brochure specifies 5000 g pull strength and field strength of more than 5000 gauss. Pull strength is a magnet rating, not a centrifuge relative-force setting. These specifications do not establish a universal separation time or recovery yield. Follow the bead-kit method and confirm collection before aspirating.

Can R0215 handle 15 mL tubes, 50 mL tubes or 96-well plates?

No, those are different formats. R0250 provides three 15 mL and three 50 mL conical-tube positions. R0096 is the 96-well plate separator. Choose the model for the sample vessel rather than trying to fit larger tubes or plates into the R0215 microtube/PCR rack.

    SpecificationDetail
    BrandMTC Bio
    Catalog numberR0215
    Product typeReversible magnetic bead separation rack
    Microtube configuration8 × 1.5/2.0 mL microtubes
    PCR configuration16 × 0.1/0.2 mL PCR tubes; PCR strips supported
    Format selectionMicrotube or PCR-tube orientation; not simultaneous capacities
    Magnet assemblyDouble-sided magnets in a removable sleeve/casing
    Microtube adjustmentIncluded height-adjustment rings
    Well angle10° pitch
    Dimensions3.75 × 1.75 × 1.5 in.
    Magnet pull strength5000 g, manufacturer specification
    Magnetic field strengthMore than 5000 gauss, manufacturer specification
    OperationManual benchtop magnetic separation
    ApplicationsLow-throughput bead-based purification and nucleic acid workflows
    Not includedMicrotubes, PCR tubes or strips, magnetic beads, reagents and samples

    Ordering Information

    SpecificationDetail
    Catalog numberR0215
    Configuration8 microtubes or 16 PCR tubes; reversible
    Pack contents1 rack with removable magnet sleeve and microtube height-adjustment rings / each
    Shipping weight2 lb

    MTC Bio Shipping and Return Policy

    At Blue Tiger Scientific, we proudly distribute authentic MTC Bio products. The following policies apply to all purchases made through our store. All return requests must be initiated with Blue Tiger Scientific before being processed by MTC Bio.

    Shipping Policy

    Orders for MTC Bio products are fulfilled and shipped directly by MTC Bio using FedEx or UPS, with FedEx Ground as the default shipping method unless otherwise specified.

    • Expedited shipping options (2-Day, Overnight) are available at an additional cost.
    • MTC Bio only ships to residential or business addresses within the United States—no PO Boxes.
    • Orders placed after business hours, weekends, or holidays will be processed the next business day, pending product and carrier availability.
    • Shipping timelines may vary based on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and MTC Bio are not responsible for carrier delays, weather-related disruptions, or unforeseen delivery issues once the order has shipped.

    Return Policy

    If a return is necessary, customers must start the process with Blue Tiger Scientific before returning any products to MTC Bio.

    • All return requests must be initiated with Blue Tiger Scientific before shipping a product back to MTC Bio.
    • Customers must obtain a Return Merchandise Authorization (RMA) number from Blue Tiger Scientific before returning any item.
    • Customers are responsible for return shipping costs unless otherwise stated.
    • Opened or used products cannot be returned—only unused items in original packaging will be accepted.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer’s expense.
    • Returned items are subject to inspection, and a 20% restocking fee may be applied.
    • Refunds will cover the product cost only—shipping fees paid at the time of purchase are non-refundable.
    • Certain items, such as custom-built, special-order, or hazardous materials, may not be eligible for return.

    Important Notes

    • Some MTC Bio products are custom-made or built to order; shipping will occur once the product is ready.
    • In the event of backorders, partial shipments may be requested.
    • Occasional delays due to material shortages, import issues, or carrier problems.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.