Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments
Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316) Pocket Multi-Parameter Meter Apera Instruments

Apera PC60 pH/EC/TDS/Salinity Tester Kit (AI316)

$180.00

    Five parameters. One replaceable combo probe. pH and conductivity-based checks with a replaceable combo sensor.

    • 5 parameters pocket measurement kit
    • PC60-E / AI1211 replaceable probe
    • Includes pH/EC standards, conditioning solution, batteries and case

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PC60 / AI316

Five parameters.
One replaceable combo probe.

Bring pH and conductivity-based water checks into one pocket kit. The PC60 combines a glass pH sensor, platinum-black conductivity sensor and temperature sensor, with selected modes for pH, EC, TDS and salinity.

Choose AI316 when you need pH as well as EC-derived readings in a portable format. This is the non-Z PC60 model, not an ORP tester or a resistivity meter.

Apera PC60 pocket tester and installed standard probe
Apera PC60 · AI316 standard kit

5 parameters

Pocket measurement kit

pH, EC, TDS, salinity and temperature

PC60-E

Included combo probe

Replaceable; catalog AI1211

IP67

Waterproof body

Floatable with a backlit display

Apera PC60 case and standard kit contents
Standard-kit illustration. The text checklist identifies included parts; extra probes and supplies are separate.

Open the case. Know what is included.

The AI316 standard kit supplies the PC60 and its PC60-E / AI1211 probe, with the checking or calibration supplies appropriate to this model.

PC60 tester with PC60-E combo probe and cap, pH 4.00 and 7.00 buffers, 1413 µS/cm and 12.88 mS/cm standards, 3M KCl solution, two pH vials, two conductivity vials, four AAA batteries, lanyard, carrying case and instructions.

pH 10.01 buffer and 84 µS/cm conductivity standard are separate. The standard probe is PC60-E, not the optional PC60-DE configuration.

MATCH THE MEASUREMENT TO THE QUESTION

Where PC60 fits your work.

Hydroponic nutrient routines

Measure pH and EC, or calculated TDS with a documented factor. These answer different questions; conductivity does not identify individual nutrients.

Routine water sampling

Use selected parameter modes with temperature displayed alongside the reading. The five parameters are not five simultaneously displayed independent sensor measurements.

Teaching and mobile checks

Show how pH sensing and conductivity conversion differ while carrying one tester. Keep the two calibration routines and combo-probe care requirements distinct.

One probe does not mean one calibration routine.

Calibrate pH with pH buffers and conductivity with EC standards. The current US manual specifies 0.01 pH resolution with ±0.01 pH ±1 digit accuracy. EC accuracy is ±1% F.S.; calculated TDS and salinity do not acquire separate composition-independent accuracy claims.

The standard kit includes PC60-E, not the optional PC60-DE double-junction probe. The glass pH sensor and platinum-black conductivity sensor share the same assembly, so do not borrow a standalone pH pen’s long KCl soak or a conductivity-only pen’s water immersion storage.

Apera PC60 standard probe sensing area
The PC60-E / AI1211 is replaceable. Follow its own cleaning and conditioning instructions.

A clear routine, from setup to care.

01

Calibrate pH and EC separately

Start pH calibration at the neutral buffer, then add appropriate points. The kit supplies pH 4.00 and 7.00, not 10.01. For EC, choose 1413 µS/cm and/or 12.88 mS/cm; 84 µS/cm is separate.

02

Select the mode and conversion basis

Read pH, conductivity, calculated TDS or calculated salinity with temperature. Keep TDS factor and EC compensation settings consistent when comparing samples.

03

Protect both sensors

Follow US manual v8.3: use a tightly closed humid cap for regular storage, not immersion in pure water. If conditioning in 3M KCl is needed, do not leave the entire combo probe immersed beyond 24 hours; the EC sensor can be damaged.

Apera Instruments PC60 pH Conductivity TDS Salinity Tester Video Tutorial · Apera Instruments

A combo sensor needs a combo care plan.

The pH glass needs hydration, while the conductivity element must not be left in a prolonged KCl soak. US manual v8.3 describes regular storage in a tightly closed humid cap. It also warns against immersing the entire assembly in KCl beyond 24 hours.

Rinse between solutions without rubbing the glass. Follow the manual’s specific conditioning steps for a dried or slow probe; do not apply a long-term storage routine copied from a standalone pH pen.

Which premium pocket tester do I need?

EC60 · EC-based checks

Conductivity and temperature, with calculated TDS and low-range salinity. No pH or ORP measurement.

PC60 · Add pH

A replaceable pH/EC/temperature combo probe with calculated TDS and salinity. No verified ORP mode on non-Z PC60.

ORP60 · Read redox

A dedicated platinum ORP tester with temperature display. Not a pH or chlorine-concentration meter.

Compare other Apera measurement workflows.

These are alternative instruments, not plug-in accessories for PC60. Check the exact sensor set and method before changing formats.

Related workflow: GroStar GS1-P pH/ORP tester

Related workflow: GroStar GS4-P multi-parameter/ORP kit

PC60 buyer questions

What is included in PC60 AI316?

The kit includes PC60 with PC60-E, pH 4.00 and 7.00 buffers, 1413 µS/cm and 12.88 mS/cm standards, 3M KCl, two pH and two EC vials, four AAA batteries, lanyard, case and instructions. pH 10.01 and 84 µS/cm are separate.

Does PC60 measure ORP or accept an ORP upgrade?

No verified ORP capability or optional ORP-probe upgrade is established for the non-Z PC60. Its documented modes are pH, EC, TDS, salinity and temperature. Do not confuse it with PC60-Z or other 60-series models.

What are PC60 pH and conductivity specifications?

The pH meter range is -2.00 to 16.00 with 0.01 resolution and ±0.01 pH ±1 digit accuracy. The supplied electrode has a separately stated 0-14 pH range. EC extends to 20.00 mS/cm with ±1% F.S. accuracy.

Are TDS and salinity measured independently?

No. They are derived from conductivity. TDS factor is adjustable 0.40-1.00, default 0.71; documented salinity conversion uses a fixed linear factor of 0.5. These conversions are not direct chemical identification.

Can PC60 measure full-strength seawater?

Its salinity range ends at 10.00 ppt, below typical full-strength seawater. Select an instrument and salinity method with an appropriate range rather than extending PC60’s range by assumption.

What probe is supplied, and can I replace it?

The standard supplied probe is PC60-E, catalog AI1211. It is replaceable and combines pH, conductivity and temperature sensing. PC60-DE is a compatible optional probe in the manual, not the standard inclusion.

How do I store the combo probe?

US manual v8.3 describes a tightly closed humid cap for regular storage, not immersion in tap, RO, distilled or DI water. Do not leave the entire probe in KCl for more than 24 hours because the conductivity sensor may be damaged.

How is PC60 different from EC60?

PC60 adds pH sensing through its combined probe and includes pH buffers plus conductivity standards. EC60 is conductivity-focused with calculated TDS/salinity and no pH sensor. Neither should be selected as an ORP tester.

Choose the measurement. Confirm the kit.

Review the PC60 specifications and supplied parts, then return to the price and ordering controls. Blue Tiger Scientific can help compare the measurement, sensor and care requirements for your application.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / catalog numberPC60 / AI316
    Included standard probePC60-E / AI1211
    Probe replacementReplaceable
    Readout modespH, EC, calculated TDS, calculated salinity, temperature
    Meter pH range-2.00 to 16.00 pH
    Supplied-electrode pH range0 to 14 pH
    pH resolution0.01 pH
    pH accuracy±0.01 pH ±1 digit
    pH calibrationAutomatic 1-3 points
    Included pH buffers4.00 and 7.00; pH 10.01 is separate
    Overall EC range0 to 20.00 mS/cm
    EC resolution by range0.1 / 1 µS/cm; 0.01 mS/cm
    EC accuracy±1% F.S.
    Calculated TDS range0.1 ppm to 10.00 ppt
    TDS conversion factorAdjustable 0.40-1.00; default 0.71
    Calculated salinity range0 to 10.00 ppt
    Salinity conversionFixed linear factor 0.5
    EC calibrationAutomatic 1-3 points; 84 µS/cm, 1413 µS/cm, 12.88 mS/cm recognized
    Included EC standards1413 µS/cm and 12.88 mS/cm; 84 µS/cm is separate
    Temperature compensationAutomatic 0-50°C for applicable modes
    EC temperature coefficientAdjustable 0.00-4.00%/°C; default 2.00%/°C
    ORP capabilityNo verified ORP capability for this model
    Temperature range0 to 50°C (32 to 122°F)
    Temperature resolution0.1°C
    Temperature accuracy±0.5°C
    ProtectionIP67; floatable
    Power4 AAA alkaline batteries; included
    Automatic power offAfter 8 minutes without operation
    DisplaySelected measurement and temperature

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI316
    Standard kitPC60 tester with PC60-E combo probe and cap, pH 4.00 and 7.00 buffers, 1413 µS/cm and 12.88 mS/cm standards, 3M KCl solution, two pH vials, two conductivity vials, four AAA batteries, lanyard, carrying case and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    Apera PC60 documents

    Use the current US manual for this kit’s operation and care. The English European brochure is supplemental regional literature. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat