Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Major Science MP-510 Lively 500V power supply with color display and four terminal pairs
Major Science MP-510 exact-model Lively electrophoresis power supply
MP-510 display and navigation-button detail crop from the exact manufacturer photograph
MP-510 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
MP-510 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol
Major Science MP-510 Lively 500V power supply with color display and four terminal pairs
Major Science MP-510 exact-model Lively electrophoresis power supply
MP-510 display and navigation-button detail crop from the exact manufacturer photograph
MP-510 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
MP-510 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol

Major Science MP-510 Lively 500V Electrophoresis Power Supply

$1,439.00

    Take higher-voltage methods beyond basic two-step control. The Major Science MP-510 pairs a 500 V ceiling and 300 W maximum output with editable six-step programs for repeatable electrophoresis setup.

    • 5–500 V in 1 V increments; manufacturer-listed current range/increment: 1–800 mA / 10 mA; 300 W maximum output.
    • Constant voltage, current or power with up to six steps per program and 30 stored program files.
    • Four pairs of output terminals, a 2.4-inch TFT colour display and pause/resume without resetting the timer. Supply only; gel apparatus separate.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

MAJOR SCIENCE · MP-510

More voltage range, with the method controls to match

The MP-510 brings 5–500 V operation to the Lively platform for electrophoresis methods that need more voltage range than a 300 V supply can provide. Its 800 mA current ceiling and 300 W maximum output also give you a broader operating envelope than the compact MINI-500.

Choose constant voltage, current or power, then use a single set of conditions or build a sequence of up to six steps. With 30 stored program files and a 2.4-inch TFT colour display, MP-510 suits a bench where higher-voltage methods and repeatable setup matter together.

Major Science MP-510 exact-model Lively electrophoresis power supply
Exact MP-510 manufacturer photograph. One standalone power supply; gel apparatus is separate.

5–500 V

Voltage setting range; 1 V increments.

1–800 mA

Current setting range; 10 mA increments.

300 W

Maximum output power; consider voltage and current together.

Why choose MP-510 for this bench?

Reach the voltage your method calls for

Adjust from 5 to 500 V in 1 V increments. The extended range makes MP-510 worth considering when a validated method exceeds the Lively 300 V models' ceiling.

Keep multistage methods ready

Save up to 30 program files with as many as six steps each. Reuse established sequences instead of reconstructing each stage for every run.

Choose more than voltage or current

Constant-power operation adds another control option alongside constant voltage and current, so you can follow methods that specify power as the regulated parameter.

Manufacturer Lively-family application photograph with a separate gel tank; setup equipment shown is not included
Manufacturer Lively-family application illustration. The separate gel tank and setup leads are not included with this standalone supply.

Follow the protocol from setup to the final stage

For an electrophoresis workflow such as vertical PAGE, start with the gel format, buffer system and apparatus voltage rating. Prepare and load the apparatus according to its instructions, then select the MP-510 conditions from your method. A 500 V ceiling is useful when the method requires it, not an instruction to increase the voltage on a routine gel.

Where the protocol calls for different initial and separation conditions, enter those stages as a program and check each stage before starting. Monitor the displayed running values and the gel's progress against the method's endpoint. Keep the apparatus closed during operation and stop and isolate the output before changing connections.

Review the whole run from one colour screen

The 2.4-inch TFT colour LCD displays setting and running conditions, helping you check the selected mode and follow the run without relying on the setpoint alone. The microprocessor controller offers constant V/I/P operation and automatic voltage/current crossover.

Selecting a constant mode automatically sets the other two parameters to their maximum values; you can then change them to suit the protocol and apparatus. Make that limit check part of setup, especially when moving from a lower-voltage method to one that uses more of the MP-510's range.

MP-510 display and navigation-button detail crop from the exact manufacturer photograph
Exact MP-510 control detail. Displayed example conditions are not a recommended gel protocol.

Keep a method library at the bench

MP-510 supports up to six steps per program and 30 stored program files. Use that capacity for distinct methods or established variants, with stage conditions taken from your laboratory procedure. Built-in typical running conditions and manually editable programs help you begin without making every method a blank-page setup.

Choose timed or continuous operation to match the workflow. The timer reaches 9,999 minutes in constant mode and 999 minutes in program mode, with an alarm available for timed work. Pause and resume without resetting the timer when you need a controlled interruption.

Up to 6 steps

Define the sequence of conditions required by your method.

30 program files

Keep recurring methods available at the bench.

Pause and resume

Resume without resetting the run timer.

At higher voltage, check the power requirement too

The MP-510 is rated to 500 V, 800 mA and 300 W, but those voltage and current maxima are not a simultaneous operating point. A load drawing 800 mA at 500 V would require 400 W, beyond the supply's 300 W output limit. Use voltage multiplied by current in amperes to check the power demand of your intended conditions.

Select constant voltage when voltage is the protocol's target, constant current when current is the target, or constant power when the method calls for regulated watts. The other electrical values respond to the load within the selected limits. Review all three requirements across every programmed stage rather than checking only the highest voltage in the method.

MP-510 source-grounded voltage-current-power arithmetic examples, not an electrophoresis protocol
Source-grounded voltage × current arithmetic, not a run protocol. Ratings apply to the instrument.
MP-510 right-hand terminal bank detail, showing two of the instrument's four output-terminal pairs
Detail crop from the MP-510 manufacturer photograph. Two of the four terminal pairs are shown.

Four terminal pairs, with deliberate connection checks

The MP-510 provides four pairs of output terminals. The right-hand bank shown here contains two of those pairs; the other two are on the opposite side of the front panel. Match every connected apparatus to the run conditions and the instrument limits.

The specified protective functions include no-load and leakage detection, overload detection, over-temperature protection, and shrouded plugs and sockets. Sudden-load-change detection requires the appropriate enabling setting. Stop and isolate the output before changing equipment connections.

Fit a shared electrophoresis station

The Lively case is stackable, and the published instrument dimensions are approximately 215 × 335 × 104 mm. That can help you plan a station around the available bench area while keeping the display and connections accessible.

The photograph shows two separate Lively-family instruments to illustrate the case design. Each MP-510 order is for one power supply. Follow the supplied setup and ventilation instructions for the actual installation.

Manufacturer Lively-family stacking illustration showing two separate power supplies; each listing is for one unit
Manufacturer Lively-family stacking illustration. Two power supplies are shown; this listing supplies one unit.

Choose MP-510 for voltage range and Lively programming

Choose MP-510 over MINI-500 when the method needs more than two program steps, stored program files or constant-power control. MP-510 also raises maximum current from 400 to 800 mA and maximum output power from 120 to 300 W, while both models reach 500 V.

If the method stays within 300 V but requires substantially more current, MP-320 is the stronger fit with its 3,000 mA ceiling. If 300 V, 700 mA and 150 W cover the work, MP-310 offers the same six-step, 30-file Lively programming. Choose the electrical range you need rather than treating MP-510 as a universal upgrade.

Compare the five Major Science options

MINI-300 power supply

MINI-300

10–300 V · 10–400 mA · 60 W

2 pairs · Constant V/I · 2 steps

Compact routine gel work within 300 V and 60 W.

Alternative model: view MINI-300

MINI-500 power supply

MINI-500

10–500 V · 1–400 mA · 120 W

2 pairs · Constant V/I · 2 steps

Higher voltage and a 1 mA current minimum in the compact format.

Alternative model: view MINI-500

MP-310 power supply

MP-310

5–300 V · 1–700 mA · 150 W

4 pairs · Constant V/I/P · 6 steps; 30 files

Stored methods and constant-power control within 300 V and 150 W.

Alternative model: view MP-310

MP-320 power supply

MP-320

5–300 V · 10–3,000 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

The current-first option, with a 3 A current ceiling.

Alternative model: view MP-320

MP-510 power supply

MP-510

5–500 V · 1–800 mA · 300 W

4 pairs · Constant V/I/P · 6 steps; 30 files

500 V range with Lively programming and 300 W output.

Current model

Choose the voltage, current and power envelope together. Ratings are instrument limits, not separate allowances for every terminal pair.

What does this order cover?

Catalog number MP-510 is the standalone Major Science Lively 500V electrophoresis power supply. The listing is not a complete electrophoresis apparatus or gel-workflow bundle.

Select the gel apparatus and consumables separately for your application. Before replacing an existing supply, match its working conditions and your apparatus ratings to the MP-510, including the voltage required at each programmed stage.

If the order depends on a particular lead, mains plug or carton accessory, ask Blue Tiger Scientific to confirm that requirement before purchase.

Bench tip: When transferring a multistep method, write down the mode, target, limits and duration for every stage before entering it. This makes a saved program easier to check than a list of voltage values alone.

MP-510 buyer questions

What are the MP-510 voltage and power ratings?

Voltage is adjustable from 5 to 500 V in 1 V increments. Maximum output current is 800 mA and maximum output power is 300 W. The intended operating point must fit all three limits.

What current range and increment does Major Science specify?

The published current range/increment is 1–800 mA / 10 mA. This is not a promise of selectable 1 mA steps throughout the range. If a particular fine current setting is essential to your method, ask Blue Tiger Scientific to confirm the setting behaviour before ordering.

Does MP-510 support constant-power methods?

Yes. MP-510 offers constant voltage, constant current and constant power. Select the mode specified by your method, then review the remaining parameter limits before starting.

How many steps and stored methods are available?

A program can contain up to six steps, and the supply stores 30 program files. Programs are manually editable, with built-in typical running conditions available as starting points.

Do the four terminal pairs change the output rating?

No. MP-510 has four pairs of output terminals, while 500 V, 800 mA and 300 W remain the instrument's maximum ratings. Plan the connected apparatus around those limits rather than multiplying them by the number of terminal pairs.

Can a run recover after a mains interruption?

MP-510 includes automatic recovery after power failure. Account for that behaviour in your laboratory procedure and evaluate an interrupted run according to the method, including any effect of the time without power.

What protection features are built in?

The supply provides no-load, leakage and overload detection, over-temperature protection, and shrouded plugs and sockets. Sudden-load-change detection requires the appropriate setting to be enabled. These features complement the apparatus's normal safety procedures.

How much space does MP-510 need, and what mains input does it use?

MP-510 measures approximately 215 × 335 × 104 mm (W × L × H), weighs approximately 2.1 kg and uses 100–240 V AC, 47–60 Hz mains input. It has a stackable case and a specified operating-temperature range of 4–40°C.

    SpecificationDetail
    BrandMajor Science
    ModelMP-510
    ProductLively 500V electrophoresis power supply
    Output voltage5–500 V; 1 V increments
    Output current1–800 mA; 10 mA increments
    Maximum output power300 W
    Output modesConstant voltage, current or power
    ControllerMicroprocessor
    Output-terminal pairs4 pairs
    Display2.4-inch TFT color LCD
    ProgramUp to 6 steps; 30 stored program files
    TimerConstant mode: up to 9,999 minutes; program mode: up to 999 minutes; alarm/continuous operation
    Specified safety featuresNo-load, leakage and overload detection; over-temperature protection; shrouded plugs and sockets; sudden-load-change detection when enabled
    Input mains rating100–240 V AC, 47–60 Hz
    Operating temperature4–40°C
    Unit dimensions, W × L × HApproximately 215 × 335 × 104 mm
    ConstructionPolycarbonate housing with flame-retardant ABS faceplate
    Instrument weight, not shipping weightApproximately 2.1 kg / 4.6 lb
    Pause/resumeWithout resetting the timer
    Automatic recovery after power failureYes
    Case designStackable
    Program editingBuilt-in typical running conditions and manually editable programs
    Mode selection behaviorSelecting a target constant mode initially sets the other two parameters to maximum; the user may then change them

    Ordering Information

    Catalog no.Configuration
    MP-510One standalone power supply. Gel apparatus and workflow consumables are selected separately.

    Ordering, shipping and product support

    Before ordering: Match the voltage, current, output power and control mode required by your method and gel apparatus. MP-510 is a standalone power supply. Contact Blue Tiger Scientific if a particular lead, mains plug or carton accessory is essential to your order.

    Shipping: Blue Tiger Scientific arranges fulfillment through its suppliers. Availability and dispatch timing depend on the supplier. Shipping estimates are not guaranteed delivery dates; contact us before ordering for a time-critical experiment.

    Returns: Start all return requests with Blue Tiger Scientific. Our published policy allows requests within 14 days of delivery unless product-specific terms state otherwise, subject to eligibility and approval. Do not ship anything before receiving an RMA and return instructions. Restocking and shipping charges may apply to approved returns. International returns are not permitted under our published policy.

    Manufacturer support: Contact Blue Tiger Scientific with your order number, model, serial number and a description of the issue for help coordinating support. Applicable manufacturer warranty terms and exclusions govern any warranty claim. We will confirm the process before equipment is sent for evaluation.

    Shipping Policy · Returns & Refunds Policy

    These downloads are a technical catalogue and product brochure, not an operating manual. Follow the instructions supplied with your system.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat