Apera ORP60 Redox Pocket Tester Kit (AI315)

$135.00

    Read redox potential. Know what the number means. Dedicated ORP measurement with a replaceable platinum electrode and temperature display.

    • ±1000 mV orp range
    • ORP60-E / AI1207 replaceable probe
    • Includes 222 mV standard, KCl solution, batteries and case

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / ORP60 / AI315

Read redox potential.
Know what the number means.

The ORP60 pairs a replaceable platinum ORP electrode with a backlit mV/temperature display. Its supplied 222 mV standard and conditioning solution support a practical routine for checking the instrument before comparing suitable aqueous samples.

Choose AI315 for ORP measurement, not pH or chlorine concentration. Use the result within a defined process; an ORP number alone is not a disinfection or drinking-water safety guarantee.

Apera ORP60 pocket tester and installed standard probe
Apera ORP60 · AI315 standard kit

±1000 mV

ORP range

1 mV resolution; ±0.2% F.S. accuracy

ORP60-E

Replaceable probe

Platinum indicator and Ag/AgCl reference

IP67

Waterproof body

Temperature display; no ORP ATC

Apera ORP60 case and standard kit contents
Standard-kit illustration. The text checklist identifies included parts; extra probes and supplies are separate.

Open the case. Know what is included.

The AI315 standard kit supplies the ORP60 and its ORP60-E / AI1207 probe, with the checking or calibration supplies appropriate to this model.

ORP60 tester with ORP60-E probe and cap, 222 mV ORP standard, one vial, 3M KCl storage/conditioning solution, four AAA batteries, lanyard and carrying case.

The ORP standard is referenced to 222 mV at 25°C. It is a checking solution, not a pH calibration buffer or a direct chlorine test.

MATCH THE MEASUREMENT TO THE QUESTION

Where ORP60 fits your work.

Water-treatment trends

Monitor suitable aqueous samples within a defined ORP procedure. Redox potential depends on the solution and reference system; it is not a direct contaminant identification.

Pool and process monitoring

Use ORP as one measurement alongside the other required water-care tests. A chosen ORP threshold does not by itself establish disinfectant concentration or treatment efficacy.

Teaching and laboratory checks

Explore platinum-indicator ORP measurement relative to an Ag/AgCl reference. Compare stable results under documented conditions rather than treating unlike samples as equivalent.

Check the standard before chasing a sample reading.

The manual says routine ORP calibration is usually unnecessary. Check performance in the supplied standard after extended use; manual adjustment is available when needed. The reference is 222 mV at 25°C, and the correct standard value changes with temperature.

The replaceable ORP60-E has a platinum indicator, Ag/AgCl reference, KCl gel electrolyte and built-in temperature sensor. Temperature is displayed, but the ORP result is not automatically temperature-compensated and the standard is not automatically buffer-recognized.

Apera ORP60 standard probe sensing area
The ORP60-E / AI1207 is replaceable. Follow its own cleaning and conditioning instructions.

A clear routine, from setup to care.

01

Condition as directed

The US manual describes 3-5 minutes in the supplied KCl solution for initial activation, unnecessary with frequent use. Rinse the sensor before the standard or sample.

02

Check the temperature-correct standard value

Wait for stability in the supplied ORP standard. Compare with its temperature reference, not an automatic assumption of 222 mV at every temperature. Use the manual’s adjustment procedure only when required.

03

Measure, rinse and maintain

Rinse between solutions, stir gently and allow stabilization. Follow the ORP60-specific cleaning/conditioning instructions. For prolonged storage, use the current model guidance rather than borrowing a different pH, EC or ZenTest routine.

ORP60 Premium ORP (Redox) Tester · Apera Instruments

Temperature display is not ORP compensation.

The standard’s reference changes with temperature: the manual gives 222 mV at 25°C and 227 mV at 20°C. Compare the stable reading with the correct value for the solution temperature. Do not call this automatic temperature compensation.

ORP60 measures potential relative to its Ag/AgCl reference. It does not automatically convert the result to the standard hydrogen electrode scale, and an alarm threshold is not a safety certification.

Which premium pocket tester do I need?

EC60 · EC-based checks

Conductivity and temperature, with calculated TDS and low-range salinity. No pH or ORP measurement.

PC60 · Add pH

A replaceable pH/EC/temperature combo probe with calculated TDS and salinity. No verified ORP mode on non-Z PC60.

ORP60 · Read redox

A dedicated platinum ORP tester with temperature display. Not a pH or chlorine-concentration meter.

Compare other Apera measurement workflows.

These are alternative instruments, not plug-in accessories for ORP60. Check the exact sensor set and method before changing formats.

Related workflow: GroStar GS1-P pH/ORP tester

Related workflow: GroStar GS4-P multi-parameter/ORP kit

ORP60 buyer questions

What comes in ORP60 AI315?

The kit includes ORP60 with ORP60-E probe and cap, 222 mV ORP standard, one vial, 3M KCl storage/conditioning solution, four AAA batteries, lanyard and carrying case.

What are ORP60 range and accuracy?

The ORP range is -1000 to +1000 mV, resolution 1 mV and accuracy ±0.2% F.S. Preserve the full-scale expression rather than interpreting it as percent of each displayed result.

Does ORP60 need routine calibration?

The US manual says calibration is usually unnecessary. Check the tester in ORP standard after long use. If the error is large, a manual adjustment procedure is available; this is not automatic pH-buffer recognition.

Is the supplied standard always 222 mV?

Its labeled reference is 222 mV at 25°C. Use the correct temperature reference from the bottle/manual when checking the tester; for example, the manual gives 227 mV at 20°C.

Does ORP60 apply automatic temperature compensation?

No. It measures and displays temperature, but its ORP reading is not automatically temperature-compensated. Temperature display must not be described as ORP ATC.

Can ORP tell me chlorine concentration or prove water is safe?

No. ORP is not a direct chlorine-concentration, contaminant or potability test. Use it within a defined process and alongside the required analytical or safety procedures.

Is the ORP60 electrode replaceable?

Yes. The supplied/default replacement is ORP60-E, catalog AI1207, with platinum indicator and Ag/AgCl reference. Use the specified probe and follow its conditioning instructions.

How should I clean and condition ORP60?

Rinse between samples and use the model-specific manual for contamination cleaning and KCl conditioning. Avoid improvised aggressive cleaning. Long-term storage instructions should come from current ORP60 guidance, not another tester’s care routine.

Choose the measurement. Confirm the kit.

Review the ORP60 specifications and supplied parts, then return to the price and ordering controls. Blue Tiger Scientific can help compare the measurement, sensor and care requirements for your application.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / catalog numberORP60 / AI315
    Included standard probeORP60-E / AI1207
    Probe replacementReplaceable
    Readout modesORP and temperature
    ORP range-1000 to +1000 mV
    ORP resolution1 mV
    ORP accuracy±0.2% F.S.
    Indicator / referencePlatinum / Ag/AgCl
    Reference electrolyteKCl gel
    Included checking solution222 mV ORP standard at 25°C
    Checking / adjustmentStandard check; manual adjustment when needed
    ORP automatic temperature compensationNo; temperature display is separate
    Automatic buffer recognitionNo
    Temperature range0 to 50°C (32 to 122°F)
    Temperature resolution0.1°C
    Temperature accuracy±0.5°C
    ProtectionIP67; floatable
    Power4 AAA alkaline batteries; included
    Automatic power offAfter 8 minutes without operation
    DisplaySelected measurement and temperature

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI315
    Standard kitORP60 tester with ORP60-E probe and cap, 222 mV ORP standard, one vial, 3M KCl storage/conditioning solution, four AAA batteries, lanyard and carrying case.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    Apera ORP60 documents

    Use the current US manual for this kit’s operation and care. The English European brochure is supplemental regional literature. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.