ProSeries combines a 20,000 × g maximum RCF rating with Hi-Viz™ graduations and a FreezeTech™ temperature-indicator patch that changes color at 0°C. Select 15 or 50 mL tubes in fold-flat Eco-Plastic racks or resealable bags.
20,000 × g
Maximum RCF
0°C
FreezeTech color-change point
15 & 50 mL
Two capacities
500/case
20 packs of 25
FreezeTech visual cue
The temperature-indicator patch changes color at 0°C.
Hi-Viz graduations
Readable markings distinguish nominal capacity from maximum freeze volume.
Two bench formats
Fold-flat Eco-Plastic racks organize tubes; resealable bags suit bulk handling.
Markable flat caps
Precision-thread HDPE screw caps feature a manufacturer-rated 95 kPa seal.

Racked C2800 and C2802 organize 25 tubes at a time. Bagged C2801 and C2803 provide the same capacities and performance features in resealable packs. Every configuration contains 500 tubes per case.
C2800
Configuration: 15 mL | Eco-Plastic racks | 500 per case
Order unit: 500 pieces per CS
C2801
Configuration: 15 mL | Resealable bags | 500 per case
Order unit: 500 pieces per CS
C2802
Configuration: 50 mL | Eco-Plastic racks | 500 per case
Order unit: 500 pieces per CS
C2803
Configuration: 50 mL | Resealable bags | 500 per case
Order unit: 500 pieces per CS
MTC Bio demonstrates the visual color change of its FreezeTech patch.
Treat FreezeTech as a visual temperature cue, not a calibrated thermometer or continuous temperature logger. Respect the printed freeze-volume line and validate sample-specific freezing procedures.
The manufacturer states that the patch changes color at 0°C. It is a visual temperature indicator, not a calibrated measurement of the sample core or a time-temperature history record.
C2800 and C2801 are 15 mL; C2802 and C2803 are 50 mL. C2800/C2802 come in Eco-Plastic racks and C2801/C2803 in resealable bags. All contain 20 packs of 25, or 500 tubes per case.
Both volumes are rated to 20,000 × g maximum RCF. Confirm rotor and adapter fit and follow any lower sample, equipment or procedure limit. RCF is not the same as RPM.
Yes. MTC Bio specifies e-beam sterilization with a sterility assurance level of 10⁻⁶. Sterility depends on the intact packaging and appropriate handling after opening.
It marks the maximum allowable volume for freezing inside the tube, which differs from nominal capacity. Use that line rather than filling to the nominal volume, and follow the requirements of your sample and protocol.
Do not assume so. The tube is polypropylene, but the cap is HDPE. Although MTC Bio lists a −80°C to 120°C temperature range, confirm closure-specific limits and the intended heating cycle before use; no assembled autoclave claim is made here.
ProSeries 50 mL models and Falcon 352070/352098 are sterile polypropylene centrifuge-tube options in 500-count cases, with bagged or racked choices. MTC Bio rates ProSeries at 20,000 × g and adds the FreezeTech patch; Corning lists 16,000 RCF for Falcon 50 mL polypropylene tubes. These specifications do not establish interchangeable rotor fit or identical assay performance. Validate before substitution.
One complete case of 500 tubes with screw caps. The selected variant determines capacity and whether the 25-count inner packs are racks or resealable bags; inventory is counted in cases.