Skip to content
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm
MTC Bio FlowTubes Standard two-position cap 12 x 75 mm
MTC Bio FlowTubes No cap 12 x 75 mm
MTC Bio FlowTubes family with strainer, standard and uncapped configurations
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm
MTC Bio FlowTubes Standard two-position cap 12 x 75 mm
MTC Bio FlowTubes No cap 12 x 75 mm
MTC Bio FlowTubes family with strainer, standard and uncapped configurations

MTC Bio FlowTubes™ Flow Cytometry Tubes – 5 mL, 12 × 75 mm

$588.99

    Your flow cytometry workflow, your tube configuration.

    • 5 mL capacity: Clear polystyrene, 12 × 75 mm
    • Three cap choices: 35 µm strainer, standard or uncapped
    • Packaging flexibility: Sterile bagged, individual or tray packs; non-sterile bulk
    • Sold by case: 500, 1,000 or 4,000 tubes by model

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

ORDER NOW

Copy of What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

Copy of VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

Copy of 2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm

Choose the Right Tube for Your Flow Cytometry Workflow

Prepare and collect dissociated samples with a familiar 12 × 75 mm format. MTC Bio FlowTubes combine crystal-clear polystyrene with a choice of 35 µm strainer caps, standard two-position caps or uncapped tubes.

Five case configurations make it easy to match your protocol’s filtration, sterility and packaging needs. Every tube configuration has a 5 mL capacity.

5 mL

Tube capacity

12 × 75 mm

Tube dimensions

35 µm

Nylon mesh on strainer models

5 Options

Cap and packaging configurations

Built Around Sample Preparation

Clear Polystyrene
See the sample through the crystal-clear tube body.

Strainer-Cap Choice
T9005 and T9005-1S incorporate a 35 µm nylon mesh screen.

Controlled Neck Dimensions
MTC Bio controls neck diameter and wall thickness for consistent instrument fit.

Workflow-Ready Packaging
Choose bagged, individually wrapped, sterile tray-packed or non-sterile bulk tubes.

MTC Bio FlowTubes family with strainer, standard and uncapped configurations

One Tube Format, Three Cap Choices

Use a strainer-cap configuration when your protocol calls for sample straining. Choose the standard two-position culture cap for capped handling without a mesh screen.

Uncapped options let you select sterile tray packs or a larger non-sterile bulk case. Caps-only accessories are not included in this listing.

Match the Configuration to Your Bench

Strainer Cap

Catalogs: T9005 / T9005-1S

Mesh: 35 µm nylon

Case: 500 sterile tubes

Standard Cap

Catalog: T9010

Closure: Two-position culture cap

Case: 500 sterile tubes

Uncapped

Sterile: T9014: 1,000/case

Non-sterile: T9020: 4,000/case

Caps: Not included

Typical Applications

  • Collecting dissociated samples for flow cytometry
  • Cell-straining preparation using 35 µm cap models
  • Routine capped sample handling with T9010
  • Validated automated flow cytometry workflows

Ordering and Compatibility Tip

Order by complete case, not by individual tube. Check cap style, sterility and case count before adding to cart. Confirm tube and cap requirements for your instrument and validate your protocol before substituting another manufacturer’s consumable.

Frequently Asked Questions

What size and material are FlowTubes?

All tube configurations on this page are crystal-clear polystyrene, 12 × 75 mm, with a 5 mL capacity. Case quantities and cap styles vary by catalog number.

Which models include a 35 µm strainer cap?

T9005 and T9005-1S include a cap containing a 35 µm nylon mesh screen for cell-straining workflows. T9005 is packed 25 tubes per bag; T9005-1S is individually wrapped. Both are sterile and supplied 500 tubes per case.

When should I choose a standard cap or an uncapped tube?

Choose T9010 when you need a standard two-position culture cap rather than a strainer. Choose T9014 for sterile uncapped tubes in tray packs or T9020 for non-sterile uncapped tubes in a bulk econo-pack. Uncapped versions do not include caps.

Are all configurations sterile?

No. T9005, T9005-1S, T9010 and T9014 are sterile. T9020 is non-sterile. Select according to your protocol and maintain appropriate handling after the packaging is opened.

What does one unit ordered contain?

One unit is one complete case: 500 tubes for T9005, T9005-1S or T9010; 1,000 tubes for T9014; or 4,000 tubes for T9020. Prices and stock quantities refer to cases, not individual tubes.

Can I use these with BD FACS instruments?

MTC Bio states that FlowTubes are designed for flow cytometry equipment including BD FACS systems, with controlled neck diameter and wall thickness. Confirm your specific instrument model, sample loader and protocol requirements before use; this is not a guarantee of compatibility with every configuration.

Are FlowTubes an alternative to Falcon 352235 strainer-cap tubes?

T9005 is an option to evaluate against Corning Falcon 352235: both are 5 mL, 12 × 75 mm polystyrene tubes with a 35 µm nylon strainer cap, supplied sterile in packs of 25 and cases of 500. Corning additionally lists RNase/DNase-free status and nonpyrogenicity testing below 0.1 EU/mL for 352235; those claims are not established here for FlowTubes. They are different manufacturers’ products, not certified identical or guaranteed drop-in replacements. Validate fit, sample recovery and assay performance for your workflow.

Does a 35 µm mesh guarantee a single-cell suspension?

No. The mesh assists sample straining, but the result depends on your sample, preparation and protocol. Validate filtration, cell recovery and downstream performance rather than assuming that a nominal mesh size alone meets your assay requirements.

FACS and Falcon are trademarks of their respective owners. Blue Tiger Scientific is not affiliated with BD or Corning.

    SpecificationDetail
    BrandMTC Bio
    SeriesFlowTubes
    Capacity5 mL
    Dimensions12 × 75 mm
    Tube materialPolystyrene (PS)
    Strainer mesh35 µm nylon on T9005 and T9005-1S only
    SterilitySterile except T9020
    Ordering unitOne complete case; quantities vary

    Ordering Information

    Catalog No.CapSterilityPackagingTubes/CaseShipping Weight/Case
    T900535 µm nylon strainerSterile20 bags × 255004 lb
    T9005-1S35 µm nylon strainerSterileIndividually wrapped5005 lb
    T9010Standard two-position capSterile20 bags × 255004 lb
    T9014No capSterile4 trays × 25010006 lb
    T9020No capNon-sterileBulk econo-pack400027 lb

    MTC Bio Shipping and Return Policy

    At Blue Tiger Scientific, we proudly distribute authentic MTC Bio products. The following policies apply to all purchases made through our store. All return requests must be initiated with Blue Tiger Scientific before being processed by MTC Bio.

    Shipping Policy

    Orders for MTC Bio products are fulfilled and shipped directly by MTC Bio using FedEx or UPS, with FedEx Ground as the default shipping method unless otherwise specified.

    • Expedited shipping options (2-Day, Overnight) are available at an additional cost.
    • MTC Bio only ships to residential or business addresses within the United States—no PO Boxes.
    • Orders placed after business hours, weekends, or holidays will be processed the next business day, pending product and carrier availability.
    • Shipping timelines may vary based on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and MTC Bio are not responsible for carrier delays, weather-related disruptions, or unforeseen delivery issues once the order has shipped.

    Return Policy

    If a return is necessary, customers must start the process with Blue Tiger Scientific before returning any products to MTC Bio.

    • All return requests must be initiated with Blue Tiger Scientific before shipping a product back to MTC Bio.
    • Customers must obtain a Return Merchandise Authorization (RMA) number from Blue Tiger Scientific before returning any item.
    • Customers are responsible for return shipping costs unless otherwise stated.
    • Opened or used products cannot be returned—only unused items in original packaging will be accepted.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer’s expense.
    • Returned items are subject to inspection, and a 20% restocking fee may be applied.
    • Refunds will cover the product cost only—shipping fees paid at the time of purchase are non-refundable.
    • Certain items, such as custom-built, special-order, or hazardous materials, may not be eligible for return.

    Important Notes

    • Some MTC Bio products are custom-made or built to order; shipping will occur once the product is ready.
    • In the event of backorders, partial shipments may be requested.
    • Occasional delays due to material shortages, import issues, or carrier problems.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

by MTC Bio

MTC Bio FlowTubes™ Flow Cytometry Tubes – 5 mL, 12 × 75 mm

Authorized Dealer
Cap and Case Configuration: 35 µm strainer | Sterile | 25/bag | 500/case
MTC Bio FlowTubes 35 µm nylon strainer 12 x 75 mm

Choose the Right Tube for Your Flow Cytometry Workflow

Prepare and collect dissociated samples with a familiar 12 × 75 mm format. MTC Bio FlowTubes combine crystal-clear polystyrene with a choice of 35 µm strainer caps, standard two-position caps or uncapped tubes.

Five case configurations make it easy to match your protocol’s filtration, sterility and packaging needs. Every tube configuration has a 5 mL capacity.

5 mL

Tube capacity

12 × 75 mm

Tube dimensions

35 µm

Nylon mesh on strainer models

5 Options

Cap and packaging configurations

Built Around Sample Preparation

Clear Polystyrene
See the sample through the crystal-clear tube body.

Strainer-Cap Choice
T9005 and T9005-1S incorporate a 35 µm nylon mesh screen.

Controlled Neck Dimensions
MTC Bio controls neck diameter and wall thickness for consistent instrument fit.

Workflow-Ready Packaging
Choose bagged, individually wrapped, sterile tray-packed or non-sterile bulk tubes.

MTC Bio FlowTubes family with strainer, standard and uncapped configurations

One Tube Format, Three Cap Choices

Use a strainer-cap configuration when your protocol calls for sample straining. Choose the standard two-position culture cap for capped handling without a mesh screen.

Uncapped options let you select sterile tray packs or a larger non-sterile bulk case. Caps-only accessories are not included in this listing.

Match the Configuration to Your Bench

Strainer Cap

Catalogs: T9005 / T9005-1S

Mesh: 35 µm nylon

Case: 500 sterile tubes

Standard Cap

Catalog: T9010

Closure: Two-position culture cap

Case: 500 sterile tubes

Uncapped

Sterile: T9014: 1,000/case

Non-sterile: T9020: 4,000/case

Caps: Not included

Typical Applications

  • Collecting dissociated samples for flow cytometry
  • Cell-straining preparation using 35 µm cap models
  • Routine capped sample handling with T9010
  • Validated automated flow cytometry workflows

Ordering and Compatibility Tip

Order by complete case, not by individual tube. Check cap style, sterility and case count before adding to cart. Confirm tube and cap requirements for your instrument and validate your protocol before substituting another manufacturer’s consumable.

Frequently Asked Questions

What size and material are FlowTubes?

All tube configurations on this page are crystal-clear polystyrene, 12 × 75 mm, with a 5 mL capacity. Case quantities and cap styles vary by catalog number.

Which models include a 35 µm strainer cap?

T9005 and T9005-1S include a cap containing a 35 µm nylon mesh screen for cell-straining workflows. T9005 is packed 25 tubes per bag; T9005-1S is individually wrapped. Both are sterile and supplied 500 tubes per case.

When should I choose a standard cap or an uncapped tube?

Choose T9010 when you need a standard two-position culture cap rather than a strainer. Choose T9014 for sterile uncapped tubes in tray packs or T9020 for non-sterile uncapped tubes in a bulk econo-pack. Uncapped versions do not include caps.

Are all configurations sterile?

No. T9005, T9005-1S, T9010 and T9014 are sterile. T9020 is non-sterile. Select according to your protocol and maintain appropriate handling after the packaging is opened.

What does one unit ordered contain?

One unit is one complete case: 500 tubes for T9005, T9005-1S or T9010; 1,000 tubes for T9014; or 4,000 tubes for T9020. Prices and stock quantities refer to cases, not individual tubes.

Can I use these with BD FACS instruments?

MTC Bio states that FlowTubes are designed for flow cytometry equipment including BD FACS systems, with controlled neck diameter and wall thickness. Confirm your specific instrument model, sample loader and protocol requirements before use; this is not a guarantee of compatibility with every configuration.

Are FlowTubes an alternative to Falcon 352235 strainer-cap tubes?

T9005 is an option to evaluate against Corning Falcon 352235: both are 5 mL, 12 × 75 mm polystyrene tubes with a 35 µm nylon strainer cap, supplied sterile in packs of 25 and cases of 500. Corning additionally lists RNase/DNase-free status and nonpyrogenicity testing below 0.1 EU/mL for 352235; those claims are not established here for FlowTubes. They are different manufacturers’ products, not certified identical or guaranteed drop-in replacements. Validate fit, sample recovery and assay performance for your workflow.

Does a 35 µm mesh guarantee a single-cell suspension?

No. The mesh assists sample straining, but the result depends on your sample, preparation and protocol. Validate filtration, cell recovery and downstream performance rather than assuming that a nominal mesh size alone meets your assay requirements.

FACS and Falcon are trademarks of their respective owners. Blue Tiger Scientific is not affiliated with BD or Corning.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.