MTC Bio DuoClick™ Screw-Cap Culture Tubes – 5 mL & 14 mL

$169.18

    A confident click for your culture workflow.

    • Two-position screw cap: Aerobic at first click; airtight closure past second click
    • Two sizes, two materials: 5 mL or 14 mL; PP or PS tube bodies
    • Sterile case choices: 500 graduated tubes with attached caps; bags, racks or PP individual wraps
    • Bulk PP alternative: T8750/T8850: 1,000 non-sterile, non-graduated tubes with separate caps

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

ORDER NOW

Copy of What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

Copy of VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

Copy of 2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Copy of Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b
DuoClick 5 mL and 14 mL graduated culture tube examples

Two Clicks. A More Deliberate Culture-Tube Closure.

Choose the closure position your culture workflow needs. MTC Bio DuoClick™ tubes use a patented two-position screw cap: the first click for aerobic culturing, and past the second click for a manufacturer-described leakproof, airtight closure for anaerobic culturing.

Build your case around 5 mL or 14 mL capacity, polypropylene or polystyrene, and the packaging your bench uses. Sterile 500-tube cases include attached caps and printed graduations; non-sterile PP bulk cases are a distinctly different 1,000-tube option with separate caps and no graduations.

5 & 14 mL

Two tube capacities

PP or PS

Choose tube material

2 Positions

HDPE screw-cap closure

12 Choices

Case configurations

Designed for Controlled Handling

Audible and Tactile Click
A distinct click helps identify the closure position as the cap is rotated.

Flat, Markable Cap
A flat cap surface provides a convenient marking area.

Sterile Packaging Choices
Bagged and foam-racked configurations in PP or PS; individually wrapped sterile configurations in PP.

Clearly Different Bulk Option
T8750 and T8850 are non-sterile PP with separate caps and no graduations—not the sterile graduated configuration.

DuoClick two-position screw closure detail

A Screw Closure, Not a Snap Cap

The two-position HDPE cap is designed for rotational handling rather than a traditional snap-on closure. Select the first-click or fully closed position to match your validated culture procedure.

Important: HDPE caps are not autoclavable. Tube-body temperature ratings must not be applied to the complete capped assembly.

Choose Your Material and Case

Polypropylene (PP)

Sizes: 5 mL and 14 mL

Tube-body maximum RCF: 4,000 × g

Tube-body temperature range: −86°C to 121°C

Packaging: Sterile bags, foam racks or individual wraps; non-sterile bulk

Polystyrene (PS)

Sizes: 5 mL and 14 mL

Tube-body maximum RCF: 1,400 × g

Tube-body temperature range: 0°C to 70°C

Packaging: Sterile bags or foam racks

The Bulk Difference

Catalogs: T8750 / T8850

Case size: 1,000 PP tubes with separate caps

Sterility: Non-sterile

Graduations: None

DuoClick culture tubes in foam rack packaging

Match the Packaging to Your Bench

Choose 20 bags of 25 for grouped handling, 10 foam racks of 50 for organized access, or individually wrapped PP tubes when individual packaging is preferred. Each sterile configuration is 500 tubes per case.

Family photographs illustrate selected graduated and racked configurations. Packaging and graduation status depend on your selected catalog number; bulk models are not graduated.

See the DuoClick Closure in Action

Manufacturer video from MTC Bio. Use the current configuration guide above for sterility, material and case-count differences.

Typical Laboratory Applications

  • Aerobic culture workflows using the first-click cap position
  • Validated anaerobic culture workflows using the fully closed position
  • Routine culture handling in 5 mL or 14 mL tube formats
  • Organized bench workflows with sterile foam-rack packaging

Before You Add a Case

Check volume, material, sterility and packaging together. One cart unit is one complete case. Confirm rotor support, chemical compatibility and working conditions; do not infer strainer-cap functionality or universal instrument fit from tube dimensions.

Frequently Asked Questions

How do the two DuoClick cap positions work?

Rotate the screw cap to the first click for the aerobic position. Rotate it past the second click for the manufacturer-described leakproof, airtight closure for anaerobic culturing. A cap setting alone does not establish or validate an anaerobic culture system; follow your organism-specific protocol.

Which size should I select?

Choose 5 mL tubes in the 12 × 75 mm format or 14 mL tubes in the 17 × 100 mm format. Confirm your working volume, rack, rotor and instrument requirements rather than relying on nominal capacity alone.

How do PP and PS tubes differ?

Polypropylene (PP) tube bodies are rated by MTC Bio up to 4,000 × g and from −86°C to 121°C. Polystyrene (PS) tube bodies are rated up to 1,400 × g and from 0°C to 70°C. These are tube-material limits, not a rating for the complete capped assembly. Both use HDPE caps; validate chemical compatibility and centrifuge support for your application.

Are all versions sterile and graduated?

No. The ten 500-tube case configurations are sterile, have attached screw caps and printed graduations. T8750 (5 mL PP) and T8850 (14 mL PP) are non-sterile, non-graduated bulk cases with tubes and caps packed separately. The current manufacturer page identifies e-beam sterilization for sterile offerings.

What does one unit ordered contain?

One unit is one complete case. Sterile models contain 500 tubes: 20 bags of 25, 10 foam racks of 50, or individually wrapped tubes according to the selected catalog number. T8750 and T8850 each contain 1,000 tubes with caps supplied separately in bulk. Prices and inventory quantities refer to cases, not individual tubes.

Can I autoclave DuoClick tubes with the caps attached?

No. MTC Bio explicitly states that the HDPE DuoClick caps are not autoclavable. Do not interpret the PP tube-body temperature limit of 121°C as permission to autoclave the capped assembly. Confirm any tube-only sterilization procedure with the manufacturer and your validated laboratory protocol.

Is DuoClick an alternative to Corning Falcon 352059?

DuoClick T8830 is an option to evaluate for workflows using Falcon 352059: both are sterile 14 mL, 17 × 100 mm PP tubes with printed graduations, supplied 25 per pack and 500 per case. DuoClick uses an HDPE two-position screw cap, while Falcon 352059 uses a polyethylene dual-position snap cap. MTC Bio rates its PP tubes to 4,000 × g; Corning rates 352059 to 3,000 × g and additionally specifies RNase/DNase-free status and nonpyrogenicity testing below 0.1 EU/mL. Those additional claims are not established here for DuoClick. These are different products, not proven identical, OEM equivalents or guaranteed drop-in replacements. Validate fit and assay performance before switching.

Are these the same as strainer-cap flow cytometry tubes?

No. DuoClick uses a two-position screw closure and does not include a cell-strainer mesh. If your protocol calls for a strainer cap or specific flow cytometer fit, select a tube intended for that purpose and validate compatibility. Do not substitute based only on a 12 × 75 mm tube dimension.

Falcon is a trademark of its respective owner. Blue Tiger Scientific is not affiliated with Corning.

    SpecificationDetail
    Brand / seriesMTC Bio / DuoClick™
    5 mL dimensions12 × 75 mm
    14 mL dimensions17 × 100 mm
    Tube materialsPP (polypropylene) or PS (polystyrene)
    ClosureTwo-position HDPE screw cap; not autoclavable
    PP tube-body limitsUp to 4,000 × g; −86°C to 121°C
    PS tube-body limitsUp to 1,400 × g; 0°C to 70°C
    Rating cautionTube-body limits do not establish complete capped-assembly performance
    Sterile configurations500 tubes/case; attached caps; printed graduations; current manufacturer page identifies e-beam sterilization
    Non-sterile configurationsT8750 and T8850: 1,000 PP tubes/case, separate caps, non-graduated
    Ordering unitOne complete case

    Choose Your DuoClick Case

    Catalog No.VolumeMaterialSterilityPackagingTubes/CaseCap & GraduationsShipping Weight/Case
    T87305 mLPPSterile20 bags × 25500Attached; printed graduations4 lb
    T87325 mLPPSterile10 racks × 50500Attached; printed graduations4 lb
    T87345 mLPPSterileIndividual wrap500Attached; printed graduations5 lb
    T87415 mLPSSterile20 bags × 25500Attached; printed graduations4 lb
    T87425 mLPSSterile10 racks × 50500Attached; printed graduations4 lb
    T87505 mLPPNon-sterileBulk separate caps1000Separate; no graduations7 lb
    T883014 mLPPSterile20 bags × 25500Attached; printed graduations8 lb
    T883214 mLPPSterile10 racks × 50500Attached; printed graduations9 lb
    T883414 mLPPSterileIndividual wrap500Attached; printed graduations10 lb
    T884014 mLPSSterile20 bags × 25500Attached; printed graduations8 lb
    T884214 mLPSSterile10 racks × 50500Attached; printed graduations9 lb
    T885014 mLPPNon-sterileBulk separate caps1000Separate; no graduations15 lb

    MTC Bio Shipping and Return Policy

    At Blue Tiger Scientific, we proudly distribute authentic MTC Bio products. The following policies apply to all purchases made through our store. All return requests must be initiated with Blue Tiger Scientific before being processed by MTC Bio.

    Shipping Policy

    Orders for MTC Bio products are fulfilled and shipped directly by MTC Bio using FedEx or UPS, with FedEx Ground as the default shipping method unless otherwise specified.

    • Expedited shipping options (2-Day, Overnight) are available at an additional cost.
    • MTC Bio only ships to residential or business addresses within the United States—no PO Boxes.
    • Orders placed after business hours, weekends, or holidays will be processed the next business day, pending product and carrier availability.
    • Shipping timelines may vary based on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and MTC Bio are not responsible for carrier delays, weather-related disruptions, or unforeseen delivery issues once the order has shipped.

    Return Policy

    If a return is necessary, customers must start the process with Blue Tiger Scientific before returning any products to MTC Bio.

    • All return requests must be initiated with Blue Tiger Scientific before shipping a product back to MTC Bio.
    • Customers must obtain a Return Merchandise Authorization (RMA) number from Blue Tiger Scientific before returning any item.
    • Customers are responsible for return shipping costs unless otherwise stated.
    • Opened or used products cannot be returned—only unused items in original packaging will be accepted.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer’s expense.
    • Returned items are subject to inspection, and a 20% restocking fee may be applied.
    • Refunds will cover the product cost only—shipping fees paid at the time of purchase are non-refundable.
    • Certain items, such as custom-built, special-order, or hazardous materials, may not be eligible for return.

    Important Notes

    • Some MTC Bio products are custom-made or built to order; shipping will occur once the product is ready.
    • In the event of backorders, partial shipments may be requested.
    • Occasional delays due to material shortages, import issues, or carrier problems.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

by MTC Bio

MTC Bio DuoClick™ Screw-Cap Culture Tubes – 5 mL & 14 mL

Authorized Dealer
Volume: 5 mL
Tube Material: PP
Case Configuration: T8730 | Sterile | 20 bags × 25 | 500/case
DuoClick 5 mL and 14 mL graduated culture tube examples

Two Clicks. A More Deliberate Culture-Tube Closure.

Choose the closure position your culture workflow needs. MTC Bio DuoClick™ tubes use a patented two-position screw cap: the first click for aerobic culturing, and past the second click for a manufacturer-described leakproof, airtight closure for anaerobic culturing.

Build your case around 5 mL or 14 mL capacity, polypropylene or polystyrene, and the packaging your bench uses. Sterile 500-tube cases include attached caps and printed graduations; non-sterile PP bulk cases are a distinctly different 1,000-tube option with separate caps and no graduations.

5 & 14 mL

Two tube capacities

PP or PS

Choose tube material

2 Positions

HDPE screw-cap closure

12 Choices

Case configurations

Designed for Controlled Handling

Audible and Tactile Click
A distinct click helps identify the closure position as the cap is rotated.

Flat, Markable Cap
A flat cap surface provides a convenient marking area.

Sterile Packaging Choices
Bagged and foam-racked configurations in PP or PS; individually wrapped sterile configurations in PP.

Clearly Different Bulk Option
T8750 and T8850 are non-sterile PP with separate caps and no graduations—not the sterile graduated configuration.

DuoClick two-position screw closure detail

A Screw Closure, Not a Snap Cap

The two-position HDPE cap is designed for rotational handling rather than a traditional snap-on closure. Select the first-click or fully closed position to match your validated culture procedure.

Important: HDPE caps are not autoclavable. Tube-body temperature ratings must not be applied to the complete capped assembly.

Choose Your Material and Case

Polypropylene (PP)

Sizes: 5 mL and 14 mL

Tube-body maximum RCF: 4,000 × g

Tube-body temperature range: −86°C to 121°C

Packaging: Sterile bags, foam racks or individual wraps; non-sterile bulk

Polystyrene (PS)

Sizes: 5 mL and 14 mL

Tube-body maximum RCF: 1,400 × g

Tube-body temperature range: 0°C to 70°C

Packaging: Sterile bags or foam racks

The Bulk Difference

Catalogs: T8750 / T8850

Case size: 1,000 PP tubes with separate caps

Sterility: Non-sterile

Graduations: None

DuoClick culture tubes in foam rack packaging

Match the Packaging to Your Bench

Choose 20 bags of 25 for grouped handling, 10 foam racks of 50 for organized access, or individually wrapped PP tubes when individual packaging is preferred. Each sterile configuration is 500 tubes per case.

Family photographs illustrate selected graduated and racked configurations. Packaging and graduation status depend on your selected catalog number; bulk models are not graduated.

See the DuoClick Closure in Action

Manufacturer video from MTC Bio. Use the current configuration guide above for sterility, material and case-count differences.

Typical Laboratory Applications

  • Aerobic culture workflows using the first-click cap position
  • Validated anaerobic culture workflows using the fully closed position
  • Routine culture handling in 5 mL or 14 mL tube formats
  • Organized bench workflows with sterile foam-rack packaging

Before You Add a Case

Check volume, material, sterility and packaging together. One cart unit is one complete case. Confirm rotor support, chemical compatibility and working conditions; do not infer strainer-cap functionality or universal instrument fit from tube dimensions.

Frequently Asked Questions

How do the two DuoClick cap positions work?

Rotate the screw cap to the first click for the aerobic position. Rotate it past the second click for the manufacturer-described leakproof, airtight closure for anaerobic culturing. A cap setting alone does not establish or validate an anaerobic culture system; follow your organism-specific protocol.

Which size should I select?

Choose 5 mL tubes in the 12 × 75 mm format or 14 mL tubes in the 17 × 100 mm format. Confirm your working volume, rack, rotor and instrument requirements rather than relying on nominal capacity alone.

How do PP and PS tubes differ?

Polypropylene (PP) tube bodies are rated by MTC Bio up to 4,000 × g and from −86°C to 121°C. Polystyrene (PS) tube bodies are rated up to 1,400 × g and from 0°C to 70°C. These are tube-material limits, not a rating for the complete capped assembly. Both use HDPE caps; validate chemical compatibility and centrifuge support for your application.

Are all versions sterile and graduated?

No. The ten 500-tube case configurations are sterile, have attached screw caps and printed graduations. T8750 (5 mL PP) and T8850 (14 mL PP) are non-sterile, non-graduated bulk cases with tubes and caps packed separately. The current manufacturer page identifies e-beam sterilization for sterile offerings.

What does one unit ordered contain?

One unit is one complete case. Sterile models contain 500 tubes: 20 bags of 25, 10 foam racks of 50, or individually wrapped tubes according to the selected catalog number. T8750 and T8850 each contain 1,000 tubes with caps supplied separately in bulk. Prices and inventory quantities refer to cases, not individual tubes.

Can I autoclave DuoClick tubes with the caps attached?

No. MTC Bio explicitly states that the HDPE DuoClick caps are not autoclavable. Do not interpret the PP tube-body temperature limit of 121°C as permission to autoclave the capped assembly. Confirm any tube-only sterilization procedure with the manufacturer and your validated laboratory protocol.

Is DuoClick an alternative to Corning Falcon 352059?

DuoClick T8830 is an option to evaluate for workflows using Falcon 352059: both are sterile 14 mL, 17 × 100 mm PP tubes with printed graduations, supplied 25 per pack and 500 per case. DuoClick uses an HDPE two-position screw cap, while Falcon 352059 uses a polyethylene dual-position snap cap. MTC Bio rates its PP tubes to 4,000 × g; Corning rates 352059 to 3,000 × g and additionally specifies RNase/DNase-free status and nonpyrogenicity testing below 0.1 EU/mL. Those additional claims are not established here for DuoClick. These are different products, not proven identical, OEM equivalents or guaranteed drop-in replacements. Validate fit and assay performance before switching.

Are these the same as strainer-cap flow cytometry tubes?

No. DuoClick uses a two-position screw closure and does not include a cell-strainer mesh. If your protocol calls for a strainer cap or specific flow cytometer fit, select a tube intended for that purpose and validate compatibility. Do not substitute based only on a 12 × 75 mm tube dimension.

Falcon is a trademark of its respective owner. Blue Tiger Scientific is not affiliated with Corning.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.