Give us a call at (833)928-4437

Choose the closure position your culture workflow needs. MTC Bio DuoClick™ tubes use a patented two-position screw cap: the first click for aerobic culturing, and past the second click for a manufacturer-described leakproof, airtight closure for anaerobic culturing.
Build your case around 5 mL or 14 mL capacity, polypropylene or polystyrene, and the packaging your bench uses. Sterile 500-tube cases include attached caps and printed graduations; non-sterile PP bulk cases are a distinctly different 1,000-tube option with separate caps and no graduations.
5 & 14 mL
Two tube capacities
PP or PS
Choose tube material
2 Positions
HDPE screw-cap closure
12 Choices
Case configurations
Audible and Tactile Click
A distinct click helps identify the closure position as the cap is rotated.
Flat, Markable Cap
A flat cap surface provides a convenient marking area.
Sterile Packaging Choices
Bagged and foam-racked configurations in PP or PS; individually wrapped sterile configurations in PP.
Clearly Different Bulk Option
T8750 and T8850 are non-sterile PP with separate caps and no graduations—not the sterile graduated configuration.

The two-position HDPE cap is designed for rotational handling rather than a traditional snap-on closure. Select the first-click or fully closed position to match your validated culture procedure.
Important: HDPE caps are not autoclavable. Tube-body temperature ratings must not be applied to the complete capped assembly.
Polypropylene (PP)
Sizes: 5 mL and 14 mL
Tube-body maximum RCF: 4,000 × g
Tube-body temperature range: −86°C to 121°C
Packaging: Sterile bags, foam racks or individual wraps; non-sterile bulk
Polystyrene (PS)
Sizes: 5 mL and 14 mL
Tube-body maximum RCF: 1,400 × g
Tube-body temperature range: 0°C to 70°C
Packaging: Sterile bags or foam racks
The Bulk Difference
Catalogs: T8750 / T8850
Case size: 1,000 PP tubes with separate caps
Sterility: Non-sterile
Graduations: None

Choose 20 bags of 25 for grouped handling, 10 foam racks of 50 for organized access, or individually wrapped PP tubes when individual packaging is preferred. Each sterile configuration is 500 tubes per case.
Family photographs illustrate selected graduated and racked configurations. Packaging and graduation status depend on your selected catalog number; bulk models are not graduated.
Manufacturer video from MTC Bio. Use the current configuration guide above for sterility, material and case-count differences.
Check volume, material, sterility and packaging together. One cart unit is one complete case. Confirm rotor support, chemical compatibility and working conditions; do not infer strainer-cap functionality or universal instrument fit from tube dimensions.
Rotate the screw cap to the first click for the aerobic position. Rotate it past the second click for the manufacturer-described leakproof, airtight closure for anaerobic culturing. A cap setting alone does not establish or validate an anaerobic culture system; follow your organism-specific protocol.
Choose 5 mL tubes in the 12 × 75 mm format or 14 mL tubes in the 17 × 100 mm format. Confirm your working volume, rack, rotor and instrument requirements rather than relying on nominal capacity alone.
Polypropylene (PP) tube bodies are rated by MTC Bio up to 4,000 × g and from −86°C to 121°C. Polystyrene (PS) tube bodies are rated up to 1,400 × g and from 0°C to 70°C. These are tube-material limits, not a rating for the complete capped assembly. Both use HDPE caps; validate chemical compatibility and centrifuge support for your application.
No. The ten 500-tube case configurations are sterile, have attached screw caps and printed graduations. T8750 (5 mL PP) and T8850 (14 mL PP) are non-sterile, non-graduated bulk cases with tubes and caps packed separately. The current manufacturer page identifies e-beam sterilization for sterile offerings.
One unit is one complete case. Sterile models contain 500 tubes: 20 bags of 25, 10 foam racks of 50, or individually wrapped tubes according to the selected catalog number. T8750 and T8850 each contain 1,000 tubes with caps supplied separately in bulk. Prices and inventory quantities refer to cases, not individual tubes.
No. MTC Bio explicitly states that the HDPE DuoClick caps are not autoclavable. Do not interpret the PP tube-body temperature limit of 121°C as permission to autoclave the capped assembly. Confirm any tube-only sterilization procedure with the manufacturer and your validated laboratory protocol.
DuoClick T8830 is an option to evaluate for workflows using Falcon 352059: both are sterile 14 mL, 17 × 100 mm PP tubes with printed graduations, supplied 25 per pack and 500 per case. DuoClick uses an HDPE two-position screw cap, while Falcon 352059 uses a polyethylene dual-position snap cap. MTC Bio rates its PP tubes to 4,000 × g; Corning rates 352059 to 3,000 × g and additionally specifies RNase/DNase-free status and nonpyrogenicity testing below 0.1 EU/mL. Those additional claims are not established here for DuoClick. These are different products, not proven identical, OEM equivalents or guaranteed drop-in replacements. Validate fit and assay performance before switching.
No. DuoClick uses a two-position screw closure and does not include a cell-strainer mesh. If your protocol calls for a strainer cap or specific flow cytometer fit, select a tube intended for that purpose and validate compatibility. Do not substitute based only on a 12 × 75 mm tube dimension.
Falcon is a trademark of its respective owner. Blue Tiger Scientific is not affiliated with Corning.
Use this text to share information about your product.
Use this text to share information about your product.
Use this text to share information about your product.