Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

IKA RC 2 GREEN control Recirculating Chiller, 115 V Default Title Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Default Title Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA
IKA RC 2 GREEN control Recirculating Chiller, 115 V Recirculating Chiller IKA

IKA RC 2 GREEN control Recirculating Chiller, 115 V

$6,195.65

    Dedicated cooling with WiCo control and an included external sensor. RC 2 GREEN control, US 115 V, 0025007404. Connecting hoses, coolant and the external application are separate.

    • Cooling only: −30°C to ambient, subject to actual duty
    • 800 W at +20°C; 90 W at −30°C reference capacity
    • PT 100.30 sensor, WiCo and listed USB/adapter hardware supplied
    • KS 4000 ic setup requires separate connection and application review

    Shipping: Provisional 75 lb RC-package allowance, not manufacturer-measured gross. Availability, dispatch and final carton details require confirmation. Unsupported destinations are quote-only.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

IKA RC 2 GREEN CONTROL • 0025007404 • US 115 V

A dedicated cooling loop with the controls to match your method.

Remove heat from a suitable external circuit with the IKA RC 2 GREEN control. This compact recirculating chiller combines a speed-controlled compressor, adjustable PEEK pressure/suction pump and removable WiCo controller. The PT 100.30 external temperature sensor is included.

Exact US order 0025007404 is the 115 V, 50/60 Hz version. Its working range is −30°C to room temperature, with 800 W cooling at +20°C and less capacity at colder targets. It is a cooling-only instrument, not a heating/cooling circulator.

Specify the complete loop. Connecting hoses, coolant, any additional fittings and the external application equipment are separate selections. Supplied hose olives are not a complete connection kit or proof that every reactor, condenser or shaker setup is ready to run.

Genuine manufacturer photograph of RC 2 GREEN control recirculating chiller with WiCo
Manufacturer photograph. Displayed cold setpoints are illustrative chiller settings, not recommended KS 4000 ic inlet settings. External equipment, connecting hoses and coolant are not included.
800 W at +20°CCooling reference, not at every temperature
−30°C to ambientCooling-only working range
PT 100.30External sensor included
WiCo controlLocal operation without a required PC

Is RC 2 GREEN control right for your application?

You need to remove heat

Choose a recirculating chiller when the job is cooling a compatible external circuit. If the method also requires active heating, select a separately specified heating/cooling system instead.

You can size at the actual target

Use the cooling-capacity reference at your target temperature and account for process heat, ambient gain, tubing and pull-down requirements. The lowest setpoint does not carry the highest cooling power.

You have a defined hydraulic circuit

Match pressure, flow resistance, materials, hose sizes and fluid limits across the complete loop. An adjustable pump does not make every external device compatible.

You want local controls and process feedback

WiCo supports local settings, timer/counter functions and programs. The included external sensor can support an appropriately configured external-control method; its presence does not validate that method automatically.

What is included in US order 0025007404?

Manufacturer photograph of PT 100.30 temperature sensor, part 0004284700
PT 100.30 is explicitly included in the current RC 2 GREEN control delivery list. Its component temperature rating does not extend the chiller’s operating limits.

Chiller, WiCo, external sensor and listed connection hardware

  • RC 2 GREEN control with WiCo wireless controller.
  • Two DN 8 hose olives and two DN 12 hose olives.
  • USB-A to Micro-B cable, 2 m.
  • PT 100.30 temperature sensor.
  • WiCo charger.

The operating manual also identifies power cables, WH 10 WiCo holder, OS 1.0 power supply, an additional USB lead, connector caps and documentation. Where a specific regional packing detail matters, confirm the current order configuration rather than treating an interface as proof that every cable or fitting is supplied.

Separate selections: connecting hoses and clamps, suitable coolant, any additional adapters or pressure safeguards, the external process device and an optional software license. DN 10 olives are a manufacturer-listed option, not an extra pair included with the supplied DN 8/DN 12 hardware.

Cooling capacity changes with the target temperature

Cooling reference at 4000 rpm: 800 W at 20, 700 W at 10, 500 W at zero, 400 W at minus 10, 200 W at minus 20 and 90 W at minus 30 degrees Celsius
Original guide based on manufacturer DIN 12876 data at 4,000 rpm. These reference capacities are not guaranteed process cooling rates.

Size the duty, not just the minimum setpoint

The current reference values are 800 W at +20°C, 700 W at +10°C, 500 W at 0°C, 400 W at −10°C, 200 W at −20°C and 90 W at −30°C. A heat-generating process at a low target may need more cooling capacity even when its setpoint lies within the chiller’s stated range.

Include external heat input, ambient conditions, tubing losses and required time to target. The 1.4–4.0 L bath-fill range is internal thermofluid volume, not a universal sample-capacity rating.

IKA describes up to 2.5 L available for the external circuit without refilling. Treat that as a fluid-management reference, not proof that any 2.5 L process will reach the target or that a larger sample is automatically unsuitable.

Select the pump operating point and the actual fittings

Maximum flow and maximum pressure are different limits

The speed-controlled PEEK pressure/suction pump adjusts from 2,000 to 4,000 rpm. Its 21 L/min maximum flow is at zero back pressure; the 0.5 bar maximum pressure is at zero discharge flow. The suction reference is 0.25 bar at zero flow. Do not combine those maxima into one performance promise.

Connections are M16×1. The supplied DN 8 and DN 12 hose olives need matching, temperature-rated hoses and secure clamps. Select the operating point from the actual circuit resistance and the manufacturer’s pump curve, while respecting the connected device’s pressure limit.

For a 10 mm-ID connection route, the manufacturer lists DN 10 hose olives / 0020004568 as an optional two-piece adapter set. It is not included here and is not, by itself, a complete KS 4000 ic installation. Review both ends of the loop, hose material, clamps, pressure protection and thermal duty.

Hydraulic planning guide distinguishing maximum flow and pressure, supplied DN8/DN12 olives and the KS 4000 ic 10 mm connection requirement
Original selection guide. Not a piping drawing or confirmation of a complete adapter/hosing configuration.

WiCo control and an included external temperature probe

Actual RC 2 GREEN control WiCo display and fluid-level detail from the manufacturer photograph
Actual control-panel crop. Displayed negative temperatures are examples, not settings for a KS 4000 ic whose inlet must remain above 3°C.

Control the cooling method, not just the display number

WiCo provides local operation, timer/counter functions and ten temperature programs with up to ten steps each. Programs remain limited by this cooling-only system’s available duty; selecting a warmer setpoint does not add an active heater.

The PT 100.30 connects to the external PT 100/LEMO interface for an appropriately configured external-control method. It is not the KS shaker’s PT 1000.60 sensor, and those sensor functions must not be interchanged by name alone.

The manual lists ±0.15 K internal temperature stability under DIN reference conditions and ±0.5 K internal/external absolute measurement accuracy, adjustable by calibration. Display resolution of 0.01 K is not 0.01 K accuracy.

Wireless operation is building-dependent, up to 15 m per the manual. Review communication timeout, safe-speed and safe-temperature settings; loss of the WiCo link or battery is not a universal automatic shutdown. USB and RS-232 support separately configured software workflows; no software license or validated electronic-recordkeeping compliance is implied.

A manufacturer-named cooling option for KS 4000 ic

KS 4000 ic shown as a separately sold external-cooling application
KS 4000 ic is a separate instrument, not included with the chiller. Its holder and the complete cooling installation are also separate selections.

Keep the shaker’s limits even when the chiller can go colder

The current KS 4000 ic manual names RC 2 GREEN basic/control as examples of external cooling units. That manufacturer relationship is useful, but it is not a guarantee that every load, hose arrangement or target temperature is already validated.

Related workflow: KS 4000 ic control with its separately specified cooling installation. The shaker requires coolant inlet above 3°C, a maximum 1 bar circuit pressure, its 10 mm-ID connection route, the permitted water/antifreeze coolant and condensate drainage under its manual.

Do not use this chiller’s −30°C lower limit as permission to send sub-zero coolant into the shaker. The shaker manual recommends pressure protection; this listing does not waive that recommendation based on a pump headline. Appropriate adapters, hoses, clamps, flow and heat-load sizing still need review.

The heating-only KS 4000 i has no ic cooling circuit. Adding a chiller does not convert that different model into an ic system.

Choose the fluid and installation for the complete circuit

Prepare the loop before commissioning

  • Define target temperature, process heat load and the external equipment’s limits.
  • Select compatible fluid, hoses, adapters and safeguards for the coldest and warmest conditions.
  • Use the manual’s filling, venting, leak-check and level-control procedures; never run without sufficient fluid.
  • Set suitable control, program and communication-loss behavior, then verify the actual method under load.

The fluid’s maximum stated viscosity is 50 mm²/s at the lowest operating temperature. Ordinary water is not a suitable assumption for operation at −30°C. Connected equipment may impose stricter fluid and temperature requirements, as KS 4000 ic does.

The manual requires at least a 9 m³ room, adequate ventilation, 20 cm free space at front and rear, and at least one hour settling after positioning before operation. R290 is flammable; it is not an explosion-proof instrument. Keep the filter and ventilation paths accessible.

Cooling-loop workflow from thermal duty and fittings to fluid selection and manual commissioning
Original planning overview, not an installation procedure or substitute for the chiller and connected-equipment manuals.

RC cooling only or an active heating/cooling system?

Selection guide comparing cooling-only RC 2 GREEN control with separately specified heating/cooling equipment and stricter KS shaker limits
Original buyer guide. The chiller’s capabilities do not override the temperature, coolant or pressure limits of the connected application.

This RC 2 GREEN control

Choose it when the job is cooling and circulating fluid, with the actual target-duty and hydraulic limits checked. Its working range is −30°C to ambient.

Need active heating as well?

Use an appropriately selected heating/cooling circulator. The RC table’s 70°C maximum with external heating is a permitted externally heated operating limit, not a supplied heater or a 70°C heating function.

Need lower-temperature duty under load?

Compare capacity at the target, not just minimum temperature. A larger refrigeration system may be needed when the heat load or time-to-target exceeds this model’s actual capability.

Alternative format: HRC 2 GREEN control for a separately specified heating-and-cooling workflow. It is a different order with its own supplied scope and application limits, not an extra heater included here.

Care, warranty and delivery planning

Inspect hoses, fittings and fluid condition, maintain the accessible front filter and follow the manual before draining or moving the unit. Isolate power for accessory changes or maintenance. Only the manufacturer should open or repair the sealed refrigeration circuit.

The manual states a 24-month baseline warranty with exclusions for wear, improper use and inadequate care. Any registration extension depends on current IKA exact-model terms; no unconditional period is promised for every accessory. Blue Tiger handles purchases and return requests; IKA handles manufacturer warranty assessment, technical support, calibration and repairs.

Shipping uses a documented 75 lb provisional RC-package allowance, not the 26.5 kg device mass as measured packed gross. Manufacturer availability, dispatch, actual cartons, carrier handling requirements and optional delivery services need order-specific confirmation. The store inventory setting is not a supplier warehouse-stock statement.

Specify the cooling duty and the connection route

For RC 2 GREEN control / US 115 V / 0025007404, tell Blue Tiger the target temperature, expected heat load, connected equipment, fluid, hose sizes/lengths and pressure limits. We can coordinate current configuration and application questions with IKA.

If the application is KS 4000 ic, name that shaker explicitly. Its inlet, fluid, pressure and drainage rules still apply, and neither a complete hose kit nor the shaker itself is supplied in this chiller order.

Confirm my cooling-loop requirements

Frequently Asked Questions

Does US RC 2 GREEN control 0025007404 include the external sensor and hoses?

PT 100.30 is explicitly included, along with WiCo, charger, two DN 8 olives, two DN 12 olives and the listed USB-A to Micro-B cable. Connecting hoses, coolant and additional application fittings are separate selections. Hose olives are adapters, not a complete installation kit.

Does it provide 800 W cooling at −30°C?

No. DIN 12876 references at 4,000 rpm are 800 W at +20°C, 700 W at +10°C, 500 W at 0°C, 400 W at −10°C, 200 W at −20°C and 90 W at −30°C. Size the cooling system for the target-temperature duty and actual external heat load.

Can RC 2 GREEN control actively heat a bath to 70°C?

It is a cooling-only chiller with a −30°C to ambient working range. The 70°C maximum with external heating is not an included heater or active heating function. If the method needs both directions, choose a separately specified heating/cooling circulator.

Can its pump deliver 21 L/min at 0.5 bar simultaneously?

No combined promise is made. The 21 L/min maximum is at zero back pressure; 0.5 bar maximum pressure is at zero discharge flow. Use the actual circuit resistance and the pump curve, while respecting the connected device’s limits.

Is this a manufacturer-named cooling option for KS 4000 ic?

Yes. The current KS 4000 ic manual names RC 2 GREEN basic/control as external-cooling examples. The complete installation still needs review: shaker inlet above 3°C, maximum 1 bar, appropriate water/antifreeze, matching 10 mm-ID connection route, pressure protection and condensate drain. This is not a turnkey shaker/chiller bundle.

Which fittings do I need for a 10 mm hose route?

The chiller has M16×1 connections and supplies DN 8/DN 12 olives. IKA lists optional DN 10 hose olives, catalog 0020004568, as a two-piece set. They are not supplied here, and a complete installation still needs correctly selected hoses, clamps, other fittings and safeguards. Do not assume every proposed adapter solves the full loop.

Does the 0.01 K display mean 0.01 K accuracy?

No. The manual lists ±0.15 K internal stability under DIN reference conditions and ±0.5 K internal/external absolute measurement accuracy, adjustable by calibration. Display resolution, stability, probe tolerance and actual method accuracy are different concepts.

Do I need a PC or an unlimited-range wireless connection?

Local operation does not require a PC. WiCo provides timer/counter functions and ten temperature programs with up to ten steps each. The manual’s up-to-15 m wireless distance depends on the building. Review communication-loss and power-return settings; no universal shutdown, cloud connection, software license or unlimited wireless reach is promised.

    Product Specifications

    ParameterDetails
    Manufacturer / modelIKA / RC 2 GREEN control
    Exact US order0025007404
    Electrical version115 V, 50/60 Hz; 350 W input
    Appliance typeRecirculating chiller, cooling only
    Working temperature−30°C to room temperature; subject to fluid, load and application limits
    External heating limitUp to 70°C with external heating; no internal heater supplied
    Cooling references+20°C: 800 W; +10°C: 700 W; 0°C: 500 W; −10°C: 400 W; −20°C: 200 W; −30°C: 90 W
    Cooling test referenceDIN 12876 at 4,000 rpm per manual
    Internal stability±0.15 K under DIN reference conditions
    Measurement accuracyInternal and external: ±0.5 K, adjustable by calibration; not display resolution
    Display / set resolution0.01 K / 0.1 K
    Control / displayPID / TFT on WiCo
    External sensorPT 100.30 included; external PT 100/LEMO interface
    Reservoir fill1.4–4.0 L per manual and US technical table; not sample capacity
    External fluid availabilityUp to 2.5 L without refilling per description; application limits still apply
    Pump / speedPEEK pressure and suction; 2,000–4,000 rpm
    Maximum flow21 L/min at zero back pressure
    Maximum pressure / suction0.5 / 0.25 bar at zero flow; not simultaneous with maximum flow
    Pump connectionsM16×1
    Supplied hose olivesDN 8: two; DN 12: two; actual hoses separate
    Optional 10 mm fittingDN 10 two-piece olive set 0020004568; separate, not a complete installation
    Fluid viscosity limit50 mm²/s at the lowest operating temperature
    RefrigerantR290, 69 g; flammable refrigerant
    InterfacesRS-232 and Micro-USB; software license separate
    ProgramsTen temperature ramps, up to ten steps each; cooling-only capability applies
    WiCo wireless distanceUp to 15 m, building-dependent; safety/timeout settings apply
    Installation basicsMinimum 9 m³ room, ventilation, 20 cm front/rear, one-hour settling before operation
    Device W × H × D220 × 475 × 525 mm; not carton dimensions
    Published device mass26.5 kg; not verified packed gross
    Permitted ambient5–32°C; maximum 80% relative humidity
    Protection / noise referenceIP21 / 61 dB(A)
    Baseline warranty24 months per manual, subject to IKA terms and wear exclusions

    Ordering Information

    ParameterDetails
    Order code / SKU0025007404 / BTS-0025007404
    Order unitOne US RC 2 GREEN control chiller
    Live listed scopeUnit/WiCo, DN8x2 and DN12x2 olives, USB-A–Micro-B 2 m cable, PT100.30 and WiCo charger
    Separate loop itemsConnecting hoses/clamps, fluid, additional adapters/safeguards and external equipment
    KS 4000 ic applicationManufacturer-named option, not a prevalidated complete bundle; inlet>3°C, max1bar, 10mm-ID route, permitted coolant and drain requirements
    Shipping planning allowance75 lb provisional RC-package allowance; not manufacturer-measured gross
    DeliveryExisting IKA Parcel Shipping profile; destination limits and special-service exceptions apply; dispatch confirmed separately

    Authorized reseller

    Blue Tiger Scientific is an authorized reseller of IKA products. We handle your purchase and requests to return an order. IKA is the manufacturer and provides manufacturer warranty coverage, technical service, calibration and repairs. Blue Tiger Scientific does not perform these services or determine warranty coverage.

    Shipping and delivery

    Availability, dispatch timing and freight depend on the product and destination. Delivery dates are estimates unless expressly confirmed as binding in writing by IKA. Contact Blue Tiger Scientific for order-specific shipping information.

    Inspect your delivery

    Inspect the equipment and packaging immediately upon receipt. Report damage, missing items or visible defects to Blue Tiger Scientific immediately, retaining photographs, packaging and shipping documents. IKA's terms require written notice of visible defects, shortages or quality deviations no later than seven days after receipt, and notice of hidden defects no later than seven days after discovery. Prompt reporting allows us to forward the information to IKA within its deadlines. Do not use or install equipment found to be defective until instructions are provided.

    Returns must start with Blue Tiger Scientific

    Contact Blue Tiger Scientific before returning any IKA product. Returns are not automatic and require IKA's written approval and an RMA number. We will provide the approved destination and return instructions; do not ship equipment to Blue Tiger or IKA without those instructions.

    IKA's published return conditions require a written return request within 60 days of shipment, and the returned goods must reach IKA within 30 days after the RMA is issued. These are manufacturer approval requirements, not an unconditional 60-day return guarantee.

    Approved returns must be in excellent, resalable condition in the original container. IKA requires its RMA and original invoice information with the return; Blue Tiger will coordinate the required order documentation. Returns not caused by an IKA error are subject to a minimum 15% restocking charge. Inspection may identify additional service or repair charges needed to restore resalable condition. Return freight is normally prepaid by the purchaser. Charges and any applicable cross-border brokerage responsibility will be confirmed with the authorization. IKA states that returns due to its own error receive full credit. Any customer refund is confirmed through Blue Tiger after the return is accepted and the applicable credit is established. Unauthorized returns may be refused and may receive no credit.

    Manufacturer warranty and service

    IKA handles warranty registration, warranty assessment, technical support, repair and calibration directly. Blue Tiger Scientific does not administer or perform manufacturer warranty service. Keep your proof of purchase and serial number, and register the product with IKA within 90 days of purchase to meet its published registration requirements.

    Warranty periods and free extensions depend on the exact product and IKA's applicable terms. No single warranty period or lifetime-warranty claim applies to all IKA products. IKA determines coverage and the applicable remedy, subject to its conditions and exclusions. For any physical return, including equipment requiring manufacturer service, contact Blue Tiger first so the required authorization and routing are confirmed; IKA handles the technical service itself.

    Cleaning before a service shipment

    Equipment sent to IKA for repair must be cleaned, safely decontaminated as applicable, and accompanied by IKA's completed and signed decontamination certificate. IKA states that it cannot process a repair without this document. Follow the specific authorization and packing instructions before dispatch.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart