Skip to content
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments
Hanna Instruments HI98713-01 ISO Turbidity Portable Meter Portable Turbidity Meter Hanna Instruments

Hanna Instruments HI98713-01 ISO Turbidity Portable Meter

$1,324.99

    Achieve superior precision in water quality analysis with the Hanna HI98713 ISO Turbidity Portable Meter. Engineered for high accuracy and ISO 7027 compliance, this portable meter provides reliable FNU readings, calibrated with included AMCO-AEPA-1 primary standards.

    • Seamless data transfer via USB.

    • Ensure precision with up to 4-point calibration.

    • Designed for field & lab versatility with battery or line power.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Exceptional Precision for Water Quality: The Hanna Instruments HI98713 Precision ISO Turbidity Portable Meter is expertly engineered for high-accuracy water quality measurements, delivering consistently reliable readings, particularly across challenging low turbidity ranges. This advanced instrument boasts a cutting-edge optical system that not only ensures precise results but also guarantees long-term operational stability by actively minimizing interference from stray light and potential color variations within the sample. To maintain optimal performance, periodic calibration with the supplied standards effectively compensates for any slight fluctuations in the intensity of its infrared LED light source. Furthermore, the use of specialized optical glass for its 25 mm round cuvettes is critical, meticulously designed to ensure the utmost repeatability of every turbidity measurement.

Features at a Glance:

  • Ratio Measurement Mode: The HI98713 meticulously measures turbidity using an advanced ratio method, incorporating both 90° and 180° light detectors to achieve exceptional accuracy across the full 0.00 to 1000 FNU (Formazin Nephelometric Unit) measurement range.
  • Multiple Reading Modes: Adaptable to various needs, the meter offers several reading modes: Normal measurement for standard readings, Continuous measurement for ongoing monitoring, and Signal Averaging measurement for enhanced stability and precision in challenging conditions.
  • ISO Compliant: Fully compliant with and exceeding the stringent requirements of ISO 7027 for turbidity measurements, the HI98713 utilizes a high-performance infrared LED light source, making it ideal for applications requiring ISO methodology.
  • Comprehensive Calibration: The HI98713 features a robust calibration function that precisely compensates for any variations in light intensity. Users can perform a highly accurate two, three, or four-point turbidity calibration using the included high-quality standards (<0.1, 15, 100, and 750 FNU). Calibration points are also fully customizable if user-prepared standards are preferred.
  • AMCO AEPA-1 Primary Turbidity Standard: The AMCO AEPA-1 standards supplied with the HI98713 are globally recognized as primary standards by the USEPA. These non-toxic standards are meticulously crafted from styrene divinylbenzene polymer spheres, ensuring uniformity in both size and density, which translates to exceptional stability, reusability, and a long shelf life.
  • Fast Tracker™ - Tag Identification System (T.I.S.): For advanced field applications, the HI98713 integrates Fast Tracker™, an innovative Tag Identification System designed to significantly simplify data collection and management. This feature enables users to effortlessly record the exact time and location of specific measurements or series of measurements by utilizing iButton® tags placed near sampling points, streamlining fieldwork. Each iButton® tag contains a unique computer chip encased in durable stainless steel.
  • GLP Data Functionality: The HI98713 incorporates comprehensive Good Laboratory Practice (GLP) functions, ensuring full traceability of your calibration conditions. This invaluable feature automatically records crucial data such as calibration points, date, and time, promoting data integrity and accountability for regulatory compliance.
  • Extensive Data Logging: The instrument's substantial internal memory can store up to 200 measurements, providing ample capacity for comprehensive data collection. These logged readings can be easily recalled at any time directly from the instrument for review.
  • Effortless Data Transfer: For further data storage, in-depth analysis, or detailed record-keeping, all logged data can be seamlessly downloaded to a Windows® compatible PC. This transfer is facilitated via either the convenient USB or RS232 port, utilizing the dedicated HI92000 software.
  • Backlit Graphic LCD Display: The HI98713 features a clear, intuitive backlit graphic LCD display. This user-friendly interface presents all messages in plain text, making them exceptionally easy to read and guiding the user step-by-step through routine operational procedures and calibration processes, even in low-light conditions.

Significance of Use

Turbidity's Role in Water Quality: Turbidity remains one of the most critical parameters for assessing the quality of both drinking water and natural water bodies. While historically considered an aesthetic characteristic, robust evidence now demonstrates that effective turbidity control acts as a vital safeguard against waterborne pathogens. In natural environments, turbidity measurements are commonly performed to gauge overall water quality and its suitability for supporting aquatic organisms. Historically, wastewater monitoring and treatment were primarily driven by turbidity control, and even today, measuring turbidity at the end of the wastewater treatment process is essential for verifying compliance with stringent regulatory standards.

The Nature of Turbidity: Turbidity in water is fundamentally an optical property that causes light to be scattered and absorbed rather than transmitted directly through the liquid. The scattering of light is predominantly caused by the presence of suspended solids. Consequently, higher turbidity levels correlate directly with a greater amount of scattered light. It is important to note that even highly purified liquids will exhibit some degree of light scattering, as a true "zero turbidity" solution is practically unattainable.

ISO Method for Turbidity Measurement: The ISO standard for turbidity measurement, as employed by the HI98713, utilizes an infrared wavelength of light (860 nm) that falls outside the visible spectrum. The primary advantage of this ISO method over the EPA method (which uses a tungsten lamp producing visible light) is its significant reduction of color interference. Since the ISO method operates outside the visible wavelength range, the color inherent in a sample does not absorb light and thus does not interfere with the turbidity measurement, ensuring more accurate results for colored samples. (Note: The USEPA typically prefers tungsten lamps for drinking water as it is expected to be clear and they offer better accuracy at very low ranges).

ISO 7027 Requirements: The requirements for an optical turbidity meter measuring diffuse radiation in low-range applications (e.g., drinking water), expressed in Formazin Nephelometric Units (FNU) according to ISO 7027, are highly specific:

  • The wavelength of the incident radiation must be 860 nm.
  • The spectral bandwidth of the incident radiation must be less than or equal to 60 nm.
  • There must be no divergence from parallelism of the incident radiation, and any convergence should not exceed 1.5°.
  • The measuring angle, theta, between the optical axis of the incident radiation and that of the diffused radiation, must be 90° ±2.5°.
  • The aperture angle should be between 20° and 30° within the water sample.

Compliance: The HI98713 is designed to meet and exceed all meter criteria specified by ISO 7027, ensuring reliable and compliant performance for your turbidity analysis needs.

Principle of Operation

Optical Principles of Turbidity Measurement: The HI98713 operates on the fundamental principle that a light beam passing through a sample is scattered in all directions by suspended particles. The intensity and pattern of this scattered light are influenced by numerous variables, including the wavelength of the incident light, the size and shape of the particles, their refractive index, and the sample's color. The advanced optical system of the HI98713 incorporates an infrared LED light source, a 90° scattered light detector, and a 180° transmitted light detector. The specific combination of detectors utilized for measurement is dynamically determined by the selected measurement mode.

Minimizing Stray Light for Accuracy: The precision of any turbidimeter, particularly at lower detection limits, is critically dependent on minimizing "stray light." Stray light refers to any light detected by the sensors that is not caused by light scattering from the suspended particles themselves. The optical system of the HI98713 is meticulously engineered to achieve extremely low stray light levels, which is crucial for delivering highly accurate and dependable results, especially when analyzing low turbidity samples.

HI98713 Turbidity Meter Light Operations Diagram
AMCO AEPA-1 Turbidity Standards

AMCO AEPA-1 Primary Standards for Turbidity Calibration

Traceable Turbidity Standards: The HI98713-11 AMCO AEPA-1 turbidity standards are engineered to provide complete measurement traceability to primary reference materials. These high-quality standards are indispensable for both precise calibration and routine performance verification of your Hanna turbidity meter, ensuring the accuracy and reliability of your readings over time.

Each Standard is Supplied with a Certificate of Analysis:
  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable
Secure Storage Containers:
  • Light tight design
  • Protects from accidental breakage
    Specification Detail
    sku HI98713-01
    FNU Range 0.00 to 9.99 FNU
    10.0 to 99.9 FNU
    100 to 1000 FNU
    FNU Resolution 0.01 FNU from 0.00 to 9.99 FNU
    0.1 FNU from 10.0 to 99.9 FNU
    1 FNU from 100 to 1000 FNU
    FNU Accuracy ±2% of reading plus 0.1 FNU
    Range Selection Automatic
    Turbidity Repeatability ±1% of reading or 0.01 FNU, whichever is greater
    Stray Light < 0.1 FNU
    Typical EMC Deviation ±0.05 FNU
    Turbidity Light Source 860 nm infrared LED
    Light Detector Silicon Photocell
    Turbidity Method Adaptation of ISO 7027, ratio method with 90° and 180° detector.
    Turbidity Standards < 0.1, 15, 100 and 750 FNU
    Calibration Two, three or four point calibration
    Display 60 x 90 mm LCD with backlight
    LOG Memory 200 records
    Serial Interface RS232 and USB 1.1
    Environment 0 to 50 °C (32 to 122 °F) max 95% RH non-condensing
    Power Supply 4 x 1.5V AA alkaline batteries or AC adapter
    Auto Shut-Off After 15 minutes of non-use
    Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0 in.)
    Weight 512 g (18 oz.)
    Warranty 2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI98713 ISO Turbidity Portable Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY