Total Phosphorus Low Range for the right phosphorus fraction. Choose the total-phosphorus method when a reactive-only measurement would omit phosphorus forms targeted by digestion. Results are not a guarantee of recovery of every compound.
Preparing Quote Cart. Your shopping cart stays unchanged.
Select the Total Phosphorus Low Range 16 mm method.
Use the phosphorus method at 150 °C for 30 minutes; reactor sold separately.
Swipe or use the arrows to browse.
Choose the total-phosphorus method when a reactive-only measurement would omit phosphorus forms targeted by digestion. Results are not a guarantee of recovery of every compound.
Reactive LR measures reactive orthophosphate without heat. Acid hydrolyzable includes free and condensed inorganic forms after heating. Total LR uses persulfate digestion for a broader total-phosphorus method.
Total Phosphorus Low Range: 0.00–1.15 mg/L as P; 0.01 mg/L resolution on HI83314 and HI83399.
Add 5 mL sample to an HI93758V-0 vial and add one PERSULFATE/P packet. Cap and shake gently for 20 seconds until the powder dissolves. Heat for 30 minutes at 150 °C, then cool to room temperature in a rack. Add 2.0 mL HI93758C-0 NaOH solution and invert gently to mix. Clean and zero the same vial before adding one HI93758-0 phosphorus reagent packet. Shake gently for 2 minutes until the powder dissolves, wait 3 minutes and read.
Use an HI83314 or HI83399 with 16 mm adapter, a 150 °C reactor such as the separately sold HI839800-01, cooling rack, accurate 5 mL and 2 mL dosing tools, wipes and SDS-directed PPE. The manual strongly recommends the HI740217 safety shield; check whether yours is already supplied.
One pack provides 50 nominal tests. The total-phosphorus method uses HI93758V-0 vials, PERSULFATE/P packets, HI93758C-0 NaOH solution and HI93758-0 phosphorus reagent. HI93758V-0 is the vial specified for this method; do not substitute the HI93758V-0AH acid-hydrolysis vial.
Read the matching current component SDS and instrument instructions before use. Never substitute an oven or microwave for the reactor: leaking samples can create a corrosive and potentially explosive atmosphere. Handle hot vials carefully. Store unused vials in their packaging in a cool, dark place. Check the manual for interference and waste requirements. Hanna classifies this offer as dangerous goods and states such goods can ship only by ground.
Total phosphorus after acid/persulfate digestion. The method targets more forms than a reactive-only measurement, but does not guarantee recovery of every compound.
0.00–1.15 mg/L as phosphorus (P), with 0.01 mg/L resolution on HI83314 and HI83399.
Use the HI83314 or HI83399 named phosphorus method with the 16 mm vial adapter. Select the correct phosphorus fraction on the instrument and follow its full procedure.
One pack provides 50 nominal tests. Plan repeat measurements, quality-control checks and sample preparation separately when estimating your testing needs.
Yes. The instrument manuals specify 150 °C for 30 minutes; use a suitable reactor and cooling rack, sold separately.
Use HI93758V-0, not HI93758V-0AH. Add the sample and PERSULFATE/P, digest, cool, then add HI93758C-0 NaOH and mix. Zero that same vial before adding HI93758-0 color reagent.
The instrument Chem Frm function converts the reported value to phosphate or phosphorus pentoxide. Conversion changes the expression basis, not the measured fraction; the listed numeric range is as P.
Arsenate must be absent; silica above 50 mg/L, sulfide, and substantial turbidity or suspended matter can interfere. Follow the instrument manual for sample treatment, wear SDS-directed PPE, and use appropriate chemical waste handling.
At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.
Instrument manuals covering the named reagent methods, not standalone reagent instructions.
Component safety references for the HI93758C-50 total-phosphorus method: HI93758V-0, PERSULFATE/P, HI93758C-0 and HI93758-0. Read the current SDS matching each supplied component before handling. These documents describe chemical safety; they are not a certificate of inspection of the supplied lot.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.