    Total Phosphorus Low Range for the right phosphorus fraction. Choose the total-phosphorus method when a reactive-only measurement would omit phosphorus forms targeted by digestion. Results are not a guarantee of recovery of every compound.

    • 0.00–1.15 mg/L as P; 50 nominal tests
    • 150 °C for 30 minutes
    • For HI83314 and HI83399 methods

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Total Phosphorus Low Range — match the measured fraction

Choose the total-phosphorus method when a reactive-only measurement would omit phosphorus forms targeted by digestion. Results are not a guarantee of recovery of every compound.

Hanna HI93758C-50 reagent kit
Manufacturer photograph; follow the supplied lot instructions.

Choose the right phosphorus fraction

Reactive LR measures reactive orthophosphate without heat. Acid hydrolyzable includes free and condensed inorganic forms after heating. Total LR uses persulfate digestion for a broader total-phosphorus method.

Total Phosphorus Low Range: 0.00–1.15 mg/L as P; 0.01 mg/L resolution on HI83314 and HI83399.

Preparation at a glance

Add 5 mL sample to an HI93758V-0 vial and add one PERSULFATE/P packet. Cap and shake gently for 20 seconds until the powder dissolves. Heat for 30 minutes at 150 °C, then cool to room temperature in a rack. Add 2.0 mL HI93758C-0 NaOH solution and invert gently to mix. Clean and zero the same vial before adding one HI93758-0 phosphorus reagent packet. Shake gently for 2 minutes until the powder dissolves, wait 3 minutes and read.

What to have on hand

Use an HI83314 or HI83399 with 16 mm adapter, a 150 °C reactor such as the separately sold HI839800-01, cooling rack, accurate 5 mL and 2 mL dosing tools, wipes and SDS-directed PPE. The manual strongly recommends the HI740217 safety shield; check whether yours is already supplied.

Pack capacity and contents

One pack provides 50 nominal tests. The total-phosphorus method uses HI93758V-0 vials, PERSULFATE/P packets, HI93758C-0 NaOH solution and HI93758-0 phosphorus reagent. HI93758V-0 is the vial specified for this method; do not substitute the HI93758V-0AH acid-hydrolysis vial.

Safe handling and method limits

Read the matching current component SDS and instrument instructions before use. Never substitute an oven or microwave for the reactor: leaking samples can create a corrosive and potentially explosive atmosphere. Handle hot vials carefully. Store unused vials in their packaging in a cool, dark place. Check the manual for interference and waste requirements. Hanna classifies this offer as dangerous goods and states such goods can ship only by ground.

Frequently Asked Questions

What fraction does this kit measure?

Total phosphorus after acid/persulfate digestion. The method targets more forms than a reactive-only measurement, but does not guarantee recovery of every compound.

What is the method range?

0.00–1.15 mg/L as phosphorus (P), with 0.01 mg/L resolution on HI83314 and HI83399.

Which photometers are supported?

Use the HI83314 or HI83399 named phosphorus method with the 16 mm vial adapter. Select the correct phosphorus fraction on the instrument and follow its full procedure.

How many tests are in one pack?

One pack provides 50 nominal tests. Plan repeat measurements, quality-control checks and sample preparation separately when estimating your testing needs.

Does this method need a reactor?

Yes. The instrument manuals specify 150 °C for 30 minutes; use a suitable reactor and cooling rack, sold separately.

Which vial and zeroing sequence does total phosphorus use?

Use HI93758V-0, not HI93758V-0AH. Add the sample and PERSULFATE/P, digest, cool, then add HI93758C-0 NaOH and mix. Zero that same vial before adding HI93758-0 color reagent.

Can results be expressed as phosphate?

The instrument Chem Frm function converts the reported value to phosphate or phosphorus pentoxide. Conversion changes the expression basis, not the measured fraction; the listed numeric range is as P.

What else should I check before use?

Arsenate must be absent; silica above 50 mg/L, sulfide, and substantial turbidity or suspended matter can interfere. Follow the instrument manual for sample treatment, wear SDS-directed PPE, and use appropriate chemical waste handling.

    Product Specifications

    SpecificationDetail
    Catalog numberHI93758C-50
    Measured fractionTotal phosphorus after acid/persulfate digestion
    Range0.00–1.15 mg/L as P
    Resolution0.01 mg/L as P
    Accuracy±0.05 mg/L or ±6% of reading, whichever is greater at 25 °C
    MethodAdaptation of EPA 365.2 and Standard Methods 20th edition 4500-P E, ascorbic acid
    Sample volume5 mL
    Digestion150 °C for 30 minutes
    Pack capacity50 nominal tests
    Compatible methodsHI83314 and HI83399; 16 mm vial adapter

    Ordering Information

    SpecificationDetail
    HI93758C-50One 50 nominal-test reagent pack

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.